AEM 30-0300

Manual del usuario del controlador de sensor AFR UEGO de banda ancha serie X AEM 30-0300

1. Introducción

This manual provides comprehensive instructions for the installation, operation, and maintenance of the AEM 30-0300 X-Series Wideband UEGO Air/Fuel Ratio (AFR) Sensor Controller Gauge. The AEM X-Series Wideband UEGO gauge utilizes advanced X-Digital technology to deliver fast and accurate air/fuel ratio readings, crucial for optimal engine tuning and monitoring.

2. Información de seguridad

WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.

Always ensure proper ventilation when working on vehicles. Disconnect the vehicle's battery before performing any electrical work. Incorrect installation or use can lead to vehicle damage or personal injury. If you are unsure about any installation steps, consult a qualified automotive technician.

3. ¿Qué hay en la caja?

The AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge package includes the following components:

Contents of AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge kit

Image 3.1: All components included with the AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge. This includes the gauge, wideband sensor, various wiring harnesses, and mounting accessories.

4. Características principales

The AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge offers several advanced features:

5. Configuración e instalación

Proper installation is critical for the accurate and reliable operation of your AEM X-Series Wideband UEGO Gauge. It is recommended that installation be performed by a qualified professional.

5.1 Instalación del sensor

The wideband UEGO sensor must be installed in the exhaust system. For optimal performance, install the sensor at least 18 inches downstream from the exhaust port, before any catalytic converters. Ensure the sensor bung is welded securely and the sensor is oriented to prevent condensation buildup.

5.2 Gauge Mounting

Mount the gauge in a location that is easily visible to the driver and protected from direct moisture and extreme heat. The gauge fits into a standard 52mm (2-1/16 inch) opening.

Lado view of AEM 30-0300 gauge showing mounting studs

Imagen 5.1: Lateral view of the AEM 30-0300 gauge, illustrating its compact design and the rear mounting studs for secure installation into a dashboard or gauge pod.

5.3 conexiones de cableado

The gauge requires power, ground, and connections to the wideband sensor. Additionally, there are output wires for data logging and feedback control. Refer to the official AEM user guide PDF for detailed wiring diagrams specific to your application.

AEM 30-0300 wideband sensor and wiring harnesses

Image 5.2: The wideband sensor and associated wiring harnesses. Proper connection of these components is essential for accurate AFR readings and data output.

For detailed wiring diagrams and installation steps, please refer to the official AEM User Guide PDF linked in Section 9.

6. Instrucciones de funcionamiento

Once properly installed and powered, the AEM X-Series Wideband UEGO Gauge will display the current Air/Fuel Ratio (AFR) or Lambda value. The gauge automatically calibrates the sensor upon startup.

6.1 Lectura de la pantalla

The large seven-segment display shows the numerical AFR value. The outer LED sweep provides a quick visual reference of the AFR range. The gauge typically displays AFR values from 8:1 (rich) to 20:1 (lean).

Close-up of AEM 30-0300 gauge display showing AFR reading

Imagen 6.1: Primer plano view of the AEM 30-0300 gauge display, showing a typical AFR reading and the surrounding LED sweep for quick visual interpretation.

6.2 Mode and Select Buttons

The gauge features 'MODE' and 'SEL' (Select) buttons, typically located on the front or side of the unit. These buttons allow you to cycle through display modes (e.g., AFR, Lambda) or perform specific functions as outlined in the detailed user manual.

7. Mantenimiento

The AEM X-Series Wideband UEGO Gauge and sensor are designed for durability, but proper maintenance ensures longevity and accuracy.

8. Solución de problemas

If you encounter issues with your AEM X-Series Wideband UEGO Gauge, consider the following common troubleshooting steps:

For more detailed troubleshooting guides and error codes, refer to the complete AEM User Guide PDF.

9. Especificaciones

EspecificaciónValor
Número de modelo30-0300
Tipo de calibreWideband UEGO AFR Sensor Controller Gauge
TecnologíaX-Digital
MostrarDigital 7-segment with LED sweep
Señales de salida0-5v Analog, RS232 Serial Port, AEMnet (CANbus)
Diámetro del calibre52 mm (2-1/16 pulgadas)
Peso del artículo0.01 ounces (Controller/Gauge only)
FabricanteAEM

10. Garantía y soporte

For warranty information, please refer to the documentation provided with your product or visit the official AEM website. AEM provides technical support for its products. If you require assistance with installation, operation, or troubleshooting beyond the scope of this manual, please contact AEM customer service directly.

11. Recursos adicionales

For the most detailed and up-to-date installation instructions, wiring diagrams, and advanced features, please download the official AEM User Guide PDF:

Descargar la Guía Oficial del Usuario (PDF)

Documentos relacionados - 30-0300

Preview AEM 30-4110 Gauge-Type UEGO Controller Installation Instructions
Detailed installation instructions for the AEM 30-4110 Gauge-Type UEGO Controller. Learn how to install, wire, and calibrate this advanced air/fuel ratio monitoring system for performance vehicles.
Preview Instrucciones de instalación AEM EMS 30-6300 para Mitsubishi Eclipse, Talon, Laser y Galant VR4
Comprehensive installation guide for the AEM Engine Management System (EMS) P/N 30-6300, designed for 1990-1994 Mitsubishi Eclipse Turbo, Talon Tsi, Dodge/Eagle Talon Tsi, Mitsubishi Eclipse RS, and Mitsubishi Galant VR4. Covers software installation, ECU removal/installation, calibration, tuning, troubleshooting, sensor configuration, wiring, and pinout diagrams.
Preview Manual de instalación del arnés adaptador PnP Infinity AEM 30-3511 para Mitsubishi EVO 8 2003-2005
Manual de instalación completo para el arnés adaptador AEM 30-3511 Infinity Plug and Play para los modelos Mitsubishi EVO 8 2003-2005. Abarca más deview, contenido del kit, opciones, notas de aplicación importantes, pasos de instalación, asistente de configuración e información de distribución de pines.
Preview Guía de instalación AEM EMS P/N 30-6320 para Mitsubishi Lancer Evolution IX y VIII
Comprehensive installation instructions and technical details for the AEM EMS P/N 30-6320 Plug and Play Engine Management System for Mitsubishi Lancer Evolution IX and VIII models. Includes setup, tuning notes, wiring diagrams, pinouts, and warranty information.
Preview Cómo convertir la unidad AEM TestPro REMOTA a la unidad PRINCIPAL
Guía paso a paso de AEM sobre cómo convertir temporalmente una unidad REMOTA TestPro en una unidad PRINCIPAL para aumentar la productividad en tareas de pruebas de red específicas.
Preview Instrucciones de instalación del AEM 21-8128DC para Ford F150 EcoBoost 2015
Guía de instalación detallada para el sistema de admisión de aire de alto rendimiento AEM 21-8128DC para los modelos Ford F150 EcoBoost 2.7L y 3.5L Turbo del 2015. Incluye lista de piezas e instrucciones paso a paso.