nVent AC0056

Manual del usuario del termostato programable nVent Home AC0056

Model: AC0056 | Brand: nVent

1. Producto terminadoview

The nVent NUHEAT Home thermostat, model AC0056, is a 7-day programmable electric floor heating thermostat. It features a 3.5-inch color touchscreen display for intuitive user interaction and energy usage monitoring. This thermostat is designed for dual voltage compatibility (120 V and 240 V) and includes a physical on/off switch, along with built-in Class A GFCI protection for safety.

Características principales:

2. Configuración e instalación

Installation of the AC0056 thermostat involves electrical wiring. It is recommended that installation be performed by a qualified electrician or a knowledgeable individual familiar with electrical systems to ensure safety and proper functionality. The thermostat is designed for wall mounting.

2.1 Cableado

The thermostat supports both 120V and 240V electrical systems. Ensure the power supply to the circuit is turned off at the main breaker before beginning any wiring. Connect the thermostat according to local electrical codes and the wiring diagram provided in the packaging. The built-in Class A GFCI provides protection against electrical leakage.

2.2 Montaje

Mount the thermostat to a standard electrical box. Ensure it is securely fastened to the wall. The physical dimensions of the thermostat are approximately 4 x 4 x 7 inches, with a screen size of 3.5 inches.

nVent Home AC0056 Thermostat with dimensions showing 5.1 inches (12 cm) height

Figure 1: nVent Home AC0056 Thermostat showing approximate dimensions for installation.

2.3 Configuración inicial

Upon initial power-up, the thermostat will guide you through a setup wizard on its touchscreen display. This wizard assists with basic settings such as date, time, temperature units, and floor type. Follow the on-screen prompts to complete the initial configuration.

3. Instrucciones de funcionamiento

The AC0056 thermostat features a touchscreen interface for all operations. The main screen typically displays the current temperature, set temperature, and operating mode.

3.1 Encendido y apagado

A physical on/off switch is located on the thermostat for quick power control. Use this switch to completely power down the unit when necessary, such as during maintenance or extended periods of non-use.

3.2 Ajuste de temperatura

Tap the temperature display on the touchscreen to adjust the desired temperature. Use the up/down arrows or a slider, if available, to set the temperature. The thermostat will maintain this temperature until a programmed schedule takes over or it is manually changed again.

3.3 Horarios de programación

The 7-day programmable feature allows you to create custom heating schedules for each day of the week. Access the programming menu via the touchscreen. You can set different temperature levels for various times of the day (e.g., morning, day, evening, night) to match your lifestyle and reduce energy consumption. The thermostat also includes an "early start" feature to ensure the floor reaches the desired temperature by the scheduled time.

3.4 Energy Usage Monitoring

The thermostat provides an energy usage monitor. Navigate to the energy usage section on the touchscreen to view historical data on your floor heating system's power consumption. This feature helps in understanding and optimizing energy efficiency.

3.5 Floor Type Settings

The thermostat is suitable for controlling heating for tile and stone floors. For laminate and engineered wood floors, a temperature limiting feature is available to prevent damage. Ensure the correct floor type is selected in the settings during initial setup or through the configuration menu.

4. Mantenimiento

The nVent Home AC0056 thermostat requires minimal maintenance. Regular cleaning of the touchscreen and exterior casing is recommended to ensure optimal performance and appearance.

5. Solución de problemas

This section addresses common issues you might encounter with your nVent Home AC0056 thermostat.

Problema Posible causa Solución
La pantalla del termostato está en blanco. No power supply; physical on/off switch is off; circuit breaker tripped. Check the circuit breaker and ensure it is on. Verify the physical on/off switch on the thermostat is in the 'on' position. If the issue persists, consult an electrician.
Floor heating not working. Thermostat not set to heat; GFCI tripped; wiring issue; floor sensor fault. Ensure the thermostat is in heating mode and the set temperature is above the ambient temperature. Check if the GFCI has tripped and reset it if necessary. If the problem continues, inspect wiring or consult a professional.
El GFCI se dispara con frecuencia. Ground fault detected in the heating system or wiring. A frequently tripping GFCI indicates a serious electrical issue. Immediately discontinue use and contact a qualified electrician to diagnose and repair the fault.
Lecturas de temperatura incorrectas. Floor sensor malfunction or improper placement. Verify the floor sensor is correctly installed and not damaged. If the sensor is faulty, it may need replacement.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact customer support or a qualified electrician.

6. Especificaciones

Marca nVent (Cable Stop)
Nombre del modelo AC0056
Tipo de controlador Pantalla táctil
Característica especial Programable
Color Blanco
Usos específicos Sistemas de calefacción por suelo radiante
Tipo de control de temperatura Programable
Componentes incluidos nVent AC0056 NUHEAT 7-Day Programmable Touchscreen Thermostat
Fuente de poder Eléctrico
Volumentage 120 V / 240 V (doble volumen)tage)
Tipo de pantalla Digital
Tamaño de pantalla 3.5 pulgadas
Método de control Tocar
Tipo de montaje Montaje en pared
Iluminar desde el fondo
Peso del artículo 11.3 onzas
Dimensiones del producto 4 x 4 x 7 pulgadas
Código Postal 620713001721, 784497454088, 740774198052

7. Garantía y soporte

7.1 Información de garantía

The provided product information states "N/a" for warranty description. For detailed warranty terms and conditions, please refer to the documentation included with your product or visit the official nVent webSitio. Conserve su comprobante de compra para cualquier reclamación de garantía.

7.2 Atención al cliente

If you require technical assistance, have questions about installation, operation, or troubleshooting that are not covered in this manual, please contact nVent customer support. Contact information can typically be found on the product packaging or the manufacturer's official websitio.

Documentos relacionados - AC0056

Preview Guía de instalación del termostato electrónico de detección de superficie nVent RAYCHEM ETS-05
Guía completa para la instalación y el funcionamiento del termostato electrónico de superficie nVent RAYCHEM ETS-05. Abarca características, aprobaciones, cableado, ubicación del sensor, configuración y mantenimiento para el control de temperatura del cable de traceado.
Preview Guía de diseño de cables calefactores con aislamiento mineral nVent RAYCHEM
Guía completa de los sistemas de trazado de calor con aislamiento mineral (MI) nVent RAYCHEM, que cubre aplicaciones, construcción, diseño térmico, selección y accesorios para trazado de calor industrial.
Preview Manual de instrucciones del aire acondicionado nVent T-Series modelo T43
Este manual proporciona instrucciones completas para la instalación, el funcionamiento y el mantenimiento del aire acondicionado nVent Serie T, modelo T43. Incluye precauciones de seguridad, consejos para la resolución de problemas y especificaciones técnicas.
Preview Manual de instrucciones del aire acondicionado nVent T-Series modelo T20
Manual de instrucciones completo para el aire acondicionado nVent serie T, modelo T20, que cubre la recepción, el manejo, la instalación, el control de temperatura, los principios de funcionamiento, el mantenimiento, la resolución de problemas e información sobre gases fluorados.
Preview Manual de instrucciones del aire acondicionado nVent T-Series modelo T62
Manual de instrucciones completo para el aire acondicionado nVent Serie T, modelo T62, que abarca la instalación, las especificaciones técnicas, el mantenimiento y la resolución de problemas. Incluye datos de diseño, listas de componentes y guías de resolución de problemas.
Preview Soluciones de trazado de calor industrial nVent: Catálogo y guía de diseño de RAYCHEM y TRACER
Guía completa de los sistemas de traceado industrial nVent RAYCHEM y nVent TRACER. Explore sistemas de calefacción de línea larga, haces de tubos y control autorregulables, con limitación de potencia y aislamiento mineral para protección contra la congelación, mantenimiento de temperatura y calentamiento de procesos.