1. Introducción

This manual provides essential instructions for the proper installation, operation, and maintenance of the Protech 61-104025-15 Service Valve. Adhering to these guidelines will ensure safe and efficient performance of the valve. Please read this manual thoroughly before proceeding with any procedures.

2. Producto terminadoview

The Protech 61-104025-15 Service Valve is a component designed for various industrial and plumbing applications, particularly within HVAC and refrigeration systems. It facilitates isolation and control of fluid flow, allowing for system servicing without complete depressurization or drainage. This valve is compatible with models such as raka, rakb, ralc, rama, ramb, ramc, ramm, ranc, rand, ranl, rapa, rapb, rapc, rapl, rapm, rara, rarl, rasl, rpka, rpkb, rpla, rplb, rpmb, rpmc, rpmd, rpmm, rpne, rpnk, rpnl, rppb, rppc, rppl, rpql, rprl, saka, sakb, spkb.

Protech 61-104025-15 Service Valve, a brass-colored valve with two sweat ODF connections and a hexagonal cap.

Figura 1: The Protech 61-104025-15 Service Valve. This image displays the brass-colored valve body, featuring two 3/4-inch sweat ODF connections on opposing sides and a hexagonal cap at the top for manual operation.

3. Configuración e instalación

Installation of the Protech 61-104025-15 Service Valve requires careful attention to connection types and proper sealing techniques. It is recommended that installation be performed by a qualified technician.

3.1 Detalles de conexión

  • Upper Connection Size: 3/4 de pulgada
  • Upper Connection Type: Sweat ODF (Outer Diameter Flare)
  • Lower Connection Size: 3/4 de pulgada
  • Lower Connection Type: Sweat ODF (Outer Diameter Flare)

3.2 Procedimiento de instalación

  1. Seguridad ante todo: Asegúrese de que el sistema esté despresurizado y drenado antes de comenzar la instalación. Use el equipo de protección personal (EPP) adecuado.
  2. Preparar conexiones: Clean the ends of the pipes and the valve's sweat connections thoroughly to remove any dirt, grease, or oxidation. Apply appropriate flux to both surfaces.
  3. Coloque la válvula: Place the valve in the desired position, ensuring proper alignment with the piping.
  4. Conexiones de soldadura: Using a suitable heat source and solder, create strong, leak-free sweat joints. Allow the joints to cool naturally.
  5. Prueba de fugas: After installation, pressurize the system and carefully check all connections for leaks using an approved leak detection method.

4. Operación

The Protech 61-104025-15 Service Valve is designed for straightforward manual operation to control or isolate fluid flow within a system.

4.1 Apertura y cierre de la válvula

  • A abierto the valve, turn the hexagonal cap counter-clockwise until the desired flow is achieved or the valve is fully open.
  • A cerca the valve, turn the hexagonal cap clockwise until the valve is fully closed and flow is stopped. Do not overtighten.

Always operate the valve smoothly and avoid sudden, forceful movements to prevent damage to the valve or system components.

5. Mantenimiento

Regular maintenance ensures the longevity and reliable performance of your Protech 61-104025-15 Service Valve.

  • Inspección periódica: Visually inspect the valve and its connections regularly for any signs of wear, corrosion, or leaks.
  • Limpieza: Keep the exterior of the valve clean. Avoid using harsh chemicals that could damage the valve material.
  • Detección de fugas: Periodically check for leaks around the valve body and connections, especially after any system pressure changes.
  • Comprobación operativa: Cycle the valve (open and close) periodically to ensure smooth operation and prevent seizing, particularly in systems where the valve remains in one position for extended periods.

6. Solución de problemas

This section addresses common issues that may arise with the service valve.

6.1 Problemas comunes y soluciones

ProblemaPosible causaSolución
Fugas en las conexionesImproper soldering; damaged pipe or valve connectionDepressurize system, repair or re-solder connection. Replace valve or pipe if damaged.
Valve difficult to turnInternal corrosion or debris; lack of lubricationDo not force. Depressurize system and inspect. If internal, valve replacement may be necessary.
No flow or restricted flow when openValve not fully open; internal obstructionEnsure valve is fully open. Depressurize system and inspect for internal debris.

Para problemas no enumerados o si las soluciones no resuelven el problema, comuníquese con un técnico de servicio calificado.

7. Especificaciones

EspecificaciónDetalle
MarcaTecnología Pro
Número de modelo61-104025-15
Upper Connection Size3/4 de pulgada
Upper Connection TypeSweat ODF
Lower Connection Size3/4 de pulgada
Lower Connection TypeSweat ODF
Acabado exteriorAcero inoxidable
Número de puertos2
Especificación cumplidaNormativa ASME B16.34
Peso del artículo11.2 onzas
Dimensiones del producto (L x An x Al)3.8 x 3.2 x 4.3 pulgadas
Código Postal662766520378

8. Información de garantía

Unless otherwise noted, all Protech items carry a one-year limited warranty from the date of purchase. Please retain your proof of purchase for warranty claims.

9. Soporte

For technical assistance, replacement parts, or further inquiries regarding the Protech 61-104025-15 Service Valve, please contact a qualified HVAC or plumbing professional. For general product information, you may visit the Tienda ProTech en Amazon.