1. Másview
The Fluke 15B+ Digital Multimeter is a rugged, reliable, and accurate tool designed for various electrical applications. It offers essential measurement capabilities in a user-friendly design, suitable for both professional and serious DIY users.

Imagen: Frente view of the Fluke 15B+ Digital Multimeter, showing the display, rotary dial, and input jacks.
Características principales:
- Clasificación de seguridad CAT III 600 V: Ensures safety for electrical systems in residential and commercial settings.
- Vol. CA / CCtage Measurement up to 1000V: Mide vol. CA y CC.tage for a wide range of applications.
- AC/DC Current Measurement up to 10A: Accurately measures AC and DC current for diagnosing electrical issues.
- Múltiples funciones de medición: Incluye vol.tage, Resistance, Continuity, Diode, and Capacitance.
- Input Terminal for AC/DC Current Measurements: Dedicated input for current measurements up to 10A.
2. Información de seguridad
Respete siempre las precauciones de seguridad al utilizar cualquier equipo de prueba eléctrica. De lo contrario, podrían producirse lesiones o daños al medidor o al equipo bajo prueba.
- Leer instrucciones: Read and understand all instructions and safety information before use.
- Uso adecuado: Use the multimeter only as specified in this manual; otherwise, the protection provided by the multimeter might be impaired.
- Vol nominaltage: No aplique más del volumen nominal.tage, como está marcado en el multímetro, entre los terminales o entre cualquier terminal y tierra.
- Inspect Leads: Inspect test leads for damaged insulation or exposed metal. Replace damaged leads.
- Avoid Live Circuits: Do not use the multimeter on live circuits with exposed conductors or bus bars.
- Equipo de protección individual (EPI): Always wear appropriate personal protective equipment, such as safety glasses and insulated gloves, when working with electrical systems.
- CAT III 600V: This meter is rated for CAT III 600V. Do not use it in environments exceeding this rating.
3. ¿Qué hay en la caja?
Your Fluke 15B+ Digital Multimeter package includes the following items:
- Fluke 15B+ Digital Multimeter
- TL75 Test Leads
- 2 pilas AA (preinstaladas o incluidas por separado)

Image: The Fluke 15B+ Digital Multimeter shown alongside its red and black TL75 test leads and protective caps.
4. Configuración
4.1 Instalación de la batería
The Fluke 15B+ requires two AA batteries for operation. These are typically included with your purchase.
- Asegúrese de que el multímetro esté apagado.
- Localice la tapa del compartimiento de la batería en la parte posterior del multímetro.
- Utilice un destornillador para aflojar los tornillos que sujetan la cubierta.
- Remove the cover and insert the two AA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Vuelva a colocar la tapa del compartimiento de la batería y ajuste el/los tornillo(s).
4.2 Conexión de cables de prueba
La conexión correcta de los cables de prueba es fundamental para realizar mediciones precisas y seguras.
- Insertar el negro cable de prueba en el COM conector de entrada (común).
- Para la mayoría de los volúmenestage, resistance, continuity, diode, and capacitance measurements, insert the rojo cable de prueba en el VΩHzCAP toma de entrada.
- For current measurements (mA/A), insert the rojo test lead into the appropriate current input jack (e.g., mA / A or 10A CON FUSIBLE), depending on the expected current level. Refer to the multimeter's faceplate for specific jack labels.
5. Instrucciones de funcionamiento
5.1 Funcionamiento general
- Encendido/apagado: Rotate the central dial from the OFF position to any desired measurement function to turn the meter on. Rotate back to OFF to power off.
- Selección de función: Use the central rotary dial to select the desired measurement function (e.g., V~ for AC Voltage, V- para volumen de CCtage, Ω para Resistencia).
- Botón de rango: Presione el GAMA button to manually select a measurement range if auto-ranging is not desired. Press again to cycle through ranges or hold to return to auto-ranging.
- Botón ESPERA: Presione el SOSTENER Botón para congelar la lectura actual en la pantalla. Presione nuevamente para liberar.
- Botón de retroiluminación: Press the backlight button (sun icon) to illuminate the display in low-light conditions.

Image: A gloved hand holding the Fluke 15B+ Digital Multimeter, demonstrating its ergonomic design.
5.2 Funciones de medición
5.2.1 Vol AC/DCtagMedición electrónica
- Gire el dial giratorio a V~ (Volumen ACtage) o V- (DC Vol.tagmi).
- Connect the black test lead to the COM terminal and the red test lead to the VΩHzCAP terminal.
- Carefully touch the test probes to the points where voltage is to be measured (in parallel with the circuit).
- Leer el vol.tage valor en la pantalla.
5.2.2 Medición de corriente CA/CC
Precaución: Always ensure the circuit is de-energized before connecting the multimeter in series for current measurements. Incorrect connection can blow the fuse or damage the meter.
- Gire el dial giratorio a A~ (Corriente CA) o A- (DC Current).
- Conecte el cable de prueba negro al terminal COM.
- Para corrientes de hasta 400 mA, conecte el cable de prueba rojo a la mA / A terminal. For currents up to 10A, connect the red test lead to the 10A CON FUSIBLE Terminal.
- Abra el circuito donde se va a medir la corriente y conecte el multímetro en serie.
- Vuelva a energizar el circuito y lea el valor actual en la pantalla.

Image: The Fluke 15B+ Digital Multimeter connected to an electrical panel, displaying a voltage lectura.
5.2.3 Medición de resistencia
- Gire el dial giratorio a Ω (Resistance).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Ensure the component or circuit under test is de-energized.
- Toque las sondas de prueba a través del componente o circuito.
- Lea el valor de resistencia en la pantalla.
5.2.4 Prueba de continuidad
- Gire el dial rotatorio a la Continuidad symbol (looks like a sound wave).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Asegúrese de que el circuito bajo prueba esté desenergizado.
- Touch the test probes across the points to be tested.
- The meter will beep if a continuous path (low resistance) is detected. The display will show the resistance value.
5.2.5 Prueba de diodos
- Gire el dial rotatorio a la Diodo symbol (looks like an arrow with a bar).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Asegúrese de que el diodo esté desconectado del circuito.
- Touch the red probe to the anode and the black probe to the cathode. A forward voltagSe debe mostrar la caída de tensión (por ejemplo, 0.5 V a 0.8 V para diodos de silicio).
- Reverse the probes. The display should show OL (Open Loop) for a good diode.
5.2.6 Medición de capacitancia
- Gire el dial rotatorio a la Capacidad symbol (looks like two parallel lines).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Asegúrese de que el condensador esté completamente descargado antes de realizar la prueba.
- Toque las sondas de prueba a través de los terminales del capacitor.
- Lea el valor de capacitancia en la pantalla.

Image: A technician wearing safety gear, using the Fluke 15B+ Digital Multimeter to take a reading inside an electrical panel.
6. Mantenimiento
6.1 Limpieza
Para limpiar el multímetro, limpie la carcasa con un paño.amp Paño y detergente suave. No utilice abrasivos ni disolventes. Asegúrese de que el medidor esté completamente seco antes de usarlo.
6.2 Reemplazo de batería
Reemplace las baterías cuando aparezca el indicador de batería baja en la pantalla. Consulte la Sección 4.1 para obtener instrucciones sobre la instalación de las baterías.
6.3 Reemplazo de fusibles
If the current measurement function stops working, the fuse may need replacement. Always replace with a fuse of the specified type and rating to maintain safety and performance.
- Asegúrese de que el multímetro esté apagado y los cables de prueba estén desconectados.
- Abra la tapa del compartimiento de la batería como se describe en la Sección 4.1.
- Retire con cuidado el fusible viejo.
- Install a new fuse of the correct type and rating (refer to the specifications section or the meter's internal markings).
- Vuelva a colocar la tapa del compartimiento de la batería y ajuste el/los tornillo(s).
7. Solución de problemas
- Sin pantalla: Verifique la instalación y la carga de las baterías. Reemplace las baterías si es necesario.
- Lecturas incorrectas: Ensure test leads are correctly connected to the appropriate input jacks for the selected function. Verify the rotary dial is set to the correct measurement function. Check for damaged test leads.
- La medición actual no funciona: Check the fuse. Replace if blown (refer to Section 6.3). Ensure the red test lead is in the correct current input jack.
- Pantalla "OL": This typically means "Overload" or "Open Loop." For resistance, it indicates an open circuit. For diode test, it indicates a reverse-biased good diode. For voltage/current, it means the measured value exceeds the selected range (if not in auto-range) or the meter's maximum capability.
8. Especificaciones
| Especificación | Valor |
|---|---|
| Número de modelo | FLUKE-15B+ |
| Clasificación de seguridad | CAT III 600 V |
| Vol. CA / CCtage | Hasta 1000 V |
| Corriente AC / DC | Hasta 10A |
| Resistencia | Sí |
| Continuidad | Sí |
| Prueba de diodo | Sí |
| Capacidad | Sí |
| Fuente de poder | 2 pilas AA (incluidas) |
| Dimensiones del producto | 8.46 x 2.76 x 5.91 pulgadas |
| Peso del artículo | 1.01 libras (460 gramos) |
| Fabricante | Corporación Fluke |
9. Garantía y soporte
The Fluke 15B+ Digital Multimeter is manufactured by Fluke Corporation. For detailed warranty information, technical support, or service, please refer to the official Fluke website or contact their customer service directly. Always ensure you purchase from authorized distributors to guarantee product authenticity and valid warranty coverage.
Para obtener recursos adicionales e información sobre el producto, visite el Tienda Fluke en Amazon.