Steinbach 040949

Manual del usuario de la bomba de filtrado Steinbach SPS 50-1T

Modelo: 040949

1. Introducción

This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Steinbach SPS 50-1T self-priming filter pump. Please read this manual thoroughly before operating the pump to ensure proper function and longevity of the product. This filter pump is designed for use with swimming pools up to approximately 22,000 liters water content.

2. Instrucciones de seguridad

Importante: Always disconnect the pump from the power supply before performing any installation, maintenance, or cleaning tasks.

3. Producto terminadoview y componentes

The Steinbach SPS 50-1T is a self-priming filter pump equipped with a pre-filter and an integrated timer. Familiarize yourself with the main components:

Steinbach SPS 50-1T Filter Pump complete view

Figura 1: En general view of the Steinbach SPS 50-1T filter pump, showing the motor, pump housing, pre-filter, and control panel.

Close-up of pre-filter with hose connection

Figura 2: Detallado view of the pre-filter assembly, showing the transparent lid and the hose connection point for the inlet.

Control panel of the Steinbach SPS 50-1T pump

Figura 3: The pump's control panel, featuring the ON/OFF button, TIMER button, and indicator lights for setting operational hours.

4. Configuración e instalación

  1. Colocación: Position the pump on a firm, level surface, ideally below the water level of the pool for easier priming. Ensure it is protected from rain and direct sunlight.
  2. Conexiones de manguera: Connect the pool's skimmer line to the pump's inlet (pre-filter side) and the return line to the pump's outlet. Use hoses with a diameter of Ø 32/38 mm. Secure all connections with hose clamps para evitar fugas.
    Pump inlet and outlet connections

    Figura 4: View of the threaded inlet and outlet ports on the pump, ready for hose adapters.

  3. Cebado de la bomba: Before starting, ensure the pre-filter is filled with water. If the pump is above water level, it may require manual priming by filling the pre-filter chamber until water flows into the pump housing.
  4. Conexión eléctrica: Plug the pump into a grounded electrical outlet (230V). Ensure the outlet is protected by a Residual Current Device (RCD) for safety.

5. Instrucciones de funcionamiento

Una vez instalada y cebada, la bomba está lista para funcionar.

5.1 Operación manual

5.2 Función de temporizador

The integrated timer allows for automated operation cycles.

  1. Ensure the pump is connected to power.
  2. Presione el MINUTERO button repeatedly to select the desired operating duration (e.g., 2, 4, 6, 8, 10, 12, 14, 16, 24 hours). The corresponding indicator light will illuminate.
  3. The pump will start and run for the selected duration, then automatically shut off.
  4. The timer cycle will repeat daily at the same time it was initially set. To reset the timer, unplug the pump for a few seconds and then plug it back in.

6. Mantenimiento

El mantenimiento regular garantiza un rendimiento óptimo y prolonga la vida útil de su bomba.

6.1 Cleaning the Pre-filter Basket

  1. Desconecte la bomba de la fuente de alimentación.
  2. Close any valves to prevent water flow from the pool.
  3. Desenrosque la tapa transparente del prefiltro.
  4. Remove the pre-filter basket and clean it thoroughly under running water.
  5. Inspeccione el sello de junta tórica en la tapa para detectar daños y asegúrese de que esté limpio.
  6. Replace the basket, secure the lid, and open the valves.
  7. Si es necesario, vuelva a cebar la bomba antes de reiniciarla.
Pre-filter with lid removed

Figura 5: The pre-filter chamber with its transparent lid removed, showing the internal basket for debris collection.

6.2 Preparación para el invierno

7. Solución de problemas

ProblemaPosible causaSolución
La bomba no arrancaSin energía; disyuntor disparado; sobrecarga del motor.Check power connection; reset circuit breaker; allow motor to cool.
La bomba funciona pero no fluye aguaPump not primed; air leak in suction line; clogged pre-filter basket; closed valves.Prime the pump; check all connections for leaks; clean pre-filter; open all valves.
Flujo de agua reducidoPartially clogged pre-filter; restricted suction or return lines; low water level in pool.Clean pre-filter; check and clear hoses; ensure adequate pool water level.
Ruido excesivoAir in pump; cavitation; motor bearing wear.Ensure pump is fully primed and no air leaks; check for obstructions in suction line; contact service if motor noise persists.

8. Especificaciones técnicas

CaracterísticaEspecificación
ModeloSPS 50-1T (040949)
Fuente de alimentación230 V/50 Hz
Consumo de energía250 vatios
Pump Power (Flow Rate)7,020 liters/hour (Q= 117 l/min)
Altura máxima de la bomba (altura)7.5 metros
Tipo de bombaSelf-priming with Pre-Filter
Conexión de mangueraDiámetro 32/38 mm
Temperatura máxima del agua35°C
Tamaño máximo de la piscina22,000 litros
Nivel de ruidoAprox. 70dB
Funciones integradasMinutero
Dimensiones del producto1 x 1 x 1 cm
Peso del artículo6 kilogramos
MaterialMetal (motor housing), Plastic (pump housing, pre-filter)

9. Garantía y soporte

For warranty information, technical support, or spare parts, please refer to the documentation provided with your purchase or contact Steinbach customer service. Keep your proof of purchase for warranty claims.

You can find more information and contact details on the official Steinbach websitio: www.steinbach.at

Documentos relacionados - 040949

Preview Steinbach Filterpumpe SPS 175-1T Bedienungsanleitung
Encuentre información detallada sobre la cama, el mantenimiento y la seguridad de la bomba con filtro Steinbach SPS 175-1T. Estos consejos se refieren a la instalación, a la instalación y a la instalación de bombas de filtro para piscinas.
Preview Manual de bombas de filtro Steinbach con/sin temporizador
Guía completa para bombas de filtrado Steinbach con y sin temporizadores, que cubre la instalación, el funcionamiento, la seguridad y la resolución de problemas.
Preview Filtro Steinbach Comfort 50 y Comfort 75: Umfassende Bedienungsanleitung
Entdecken Sie die Steinbach Filteranlage Comfort 50 y Comfort 75. Este manual contiene detalles detallados sobre instalación, cama, limpieza y seguridad para el agua de la piscina.
Preview Sello mecánico Steinbach 040912 - Especificaciones técnicas
Especificaciones técnicas detalladas y dimensiones del sello mecánico Steinbach 040912, un componente para sistemas de piscinas. Incluye dimensiones del producto e información sobre tolerancias de fabricación.