1. Producto terminadoview
The Hilti GC-22 Gas Canister (Model 38867) is designed for use with the Hilti GX-120 gas-actuated fastening tool. This canister contains 2.74 fluid ounces (81ml) of high-quality gas, formulated to provide optimal performance and reliability for fastening applications. It ensures consistent power delivery for efficient operation of the GX-120 system.

Image 1.1: The Hilti GC-22 Gas Canister. This image shows the cylindrical red and black gas canister, which is essential for powering the Hilti GX-120 fastening tool.
2. Información de seguridad
ADVERTENCIA: El incumplimiento de estas instrucciones de seguridad puede provocar lesiones graves o daños materiales.
- Flammable Gas: This canister contains highly flammable gas under pressure. Keep away from heat, hot surfaces, sparks, open flames, and other ignition sources. No smoking.
- Contenedor presurizado: No perforar ni quemar, incluso después de su uso. No exponer a temperaturas superiores a 50 °C (122 °F).
- Ventilación: Use only in well-ventilated areas. Inhalation of gas may cause dizziness or suffocation.
- Almacenamiento: Store in a cool, dry place, out of direct sunlight and away from children.
- Desecho: Dispose of contents/container in accordance with local/regional/national/international regulations. Do not empty into drains.
- Contacto con los ojos y la piel: Avoid contact with eyes and skin. In case of contact, rinse immediately with plenty of water and seek medical advice.
- Compatibilidad de herramientas: Only use this gas canister with the Hilti GX-120 gas-actuated fastening tool. Using it with incompatible tools may cause malfunction or injury.
3. Configuración e instalación
Before installing the gas canister, ensure the Hilti GX-120 tool is switched off and disconnected from any power source (if applicable) and that you are wearing appropriate personal protective equipment.
- Prepare la herramienta: Open the gas canister compartment on your Hilti GX-120 tool according to the tool's specific instruction manual.
- Insert Canister: Align the Hilti GC-22 Gas Canister with the receptacle in the tool's gas compartment. Insert the canister firmly until it clicks into place. Ensure a secure connection.
- Cerrar compartimento: Close the gas canister compartment cover securely.
- Compruebe si hay fugas: After installation, briefly check for any signs of gas leakage (e.g., hissing sound, unusual odor). If a leak is detected, remove the canister in a well-ventilated area and re-install or replace it if necessary.
4. Instrucciones de funcionamiento
The Hilti GC-22 Gas Canister provides the propellant for the Hilti GX-120 tool. Once installed, the tool is ready for operation as per its own user manual.
- Ensure the gas canister is fully inserted and the compartment is closed.
- Follow all operating procedures outlined in the Hilti GX-120 tool's instruction manual for safe and effective fastening.
- The gas canister will automatically dispense the required amount of gas with each actuation of the tool.
- Replace the canister when the tool's performance diminishes or when the canister is empty.
5. Mantenimiento y almacenamiento
5.1. Manipulación
- Handle the gas canister with care to avoid dropping or puncturing it.
- Do not attempt to refill the canister. It is designed for single use.
- Keep the canister clean and free from dirt or debris that could affect its seal or performance.
5.2. Almacenamiento
- Store unused gas canisters in their original packaging in a cool, dry, well-ventilated area.
- Mantener alejado de la luz solar directa, fuentes de calor y llamas abiertas.
- The storage temperature should not exceed 50°C (122°F).
- Mantener fuera del alcance de los niños y del personal no autorizado.
6. Solución de problemas
If you experience issues related to gas delivery or tool performance, consider the following:
- No Gas Dispensing:
- Ensure the gas canister is correctly and fully inserted into the GX-120 tool.
- Check if the canister is empty. Replace with a new Hilti GC-22 Gas Canister if necessary.
- Verify that the tool's gas compartment is properly closed.
- Reduced Tool Performance:
- A partially empty gas canister can lead to reduced power. Replace the canister.
- Ensure the tool itself is clean and well-maintained according to its own manual.
- Operating in extremely cold temperatures can affect gas pressure. Allow the canister to warm up to room temperature if possible.
- Fuga de gas:
- If you detect a gas leak, immediately remove the canister in a well-ventilated area.
- Inspect the canister for damage. Do not use a damaged canister.
- Ensure the tool's gas compartment seal is intact and free of debris.
If problems persist after following these steps, refer to the Hilti GX-120 tool's instruction manual or contact Hilti customer support.
7. Especificaciones
| Característica | Detalle |
|---|---|
| Fabricante | Hilti |
| Número de pieza | 38867 |
| Número de modelo del artículo | 38867 |
| Nombre del producto | GC-22 Gas Canister |
| Compatibilidad | Hilti GX-120 Gas-Actuated Fastening Tool |
| Volumen | 2.74 Fl. Oz. (81ml) |
| Peso del artículo | 1.6 onzas |
| Dimensiones del producto | 1.25 x 5.5 x 1.3 pulgadas |
| Color | Rojo |
| Número de piezas | 1 |
| Fecha de primera disponibilidad | 1 de enero de 2014 |
8. Garantía y soporte
For information regarding the warranty of your Hilti GC-22 Gas Canister or for technical support, please refer to the official Hilti website or contact Hilti customer service directly. Warranty terms and conditions may vary by region.
You can find contact information and further resources on the official Hilti websitio: www.hilti.com