PerfectPrime GA0080

PerfectPrime GA0080 Portable Gas Leak Detector User Manual

Modelo: GA0080

1. Introducción

The PerfectPrime GA0080 is a portable gas leak detector designed to identify the presence of natural gas (NG), methane, propane, and butane. This device utilizes a catalytic method gas sensor to provide a quick and reliable indication of gas leaks, enhancing safety in residential and commercial environments. It features a visible LED alarm system and a clear display for gas concentration readings.

2. Información importante de seguridad

Please read all instructions carefully before using the PerfectPrime GA0080. Failure to follow these instructions may result in inaccurate readings, property damage, or personal injury.

3. Contenido del paquete

Verifique que todos los artículos estén presentes en su paquete:

4. Producto terminadoview

Familiarize yourself with the components of your GA0080 gas leak detector.

PerfectPrime GA0080 Portable Gas Leak Detector, showing the display and power button.

Figura 4.1: En general view of the PerfectPrime GA0080 Portable Gas Leak Detector, highlighting the digital display and power button.

PerfectPrime GA0080 Gas Leak Detector sensor end with ventilation holes.

Figura 4.2: Close-up of the sensor end of the GA0080, showing the protective grille and ventilation holes for gas detection.

PerfectPrime GA0080 Gas Leak Detector with three LED indicators: green, yellow, and red.

Figura 4.3: Lado view of the GA0080, illustrating the three LED indicators (green, yellow, red) for visual alarm signals.

5. Configuración

5.1 Instalación de la batería

  1. Localice la tapa del compartimiento de la batería en la parte posterior del dispositivo.
  2. Deslice o desenganche la tapa para abrir el compartimento.
  3. Inserte dos (2) baterías AA de 1.5 V, asegurándose de la polaridad correcta (+/-).
  4. Cierre bien la tapa del compartimento de la batería.

Note: Always use fresh batteries for optimal performance. Remove batteries if the device will not be used for an extended period.

6. Operación

6.1 Encendido y calentamiento

  1. Mantenga presionado el botón de encendido hasta que el dispositivo se encienda.
  2. The device will enter a warm-up phase, which takes approximately 200 seconds. During this time, the display may show a countdown or "Warm Up".
  3. Once warm-up is complete, the device is ready for use, and the display will show "0 ppm" or a low background reading.

6.2 Detecting Gas Leaks

6.3 Apagado

Press and hold the Power button until the device turns off.

7. Mantenimiento

8. Solución de problemas

ProblemaPosible causaSolución
El dispositivo no se enciende.Baterías muertas o instaladas incorrectamente.Reemplace las baterías con baterías AA nuevas de 1.5 V, asegurándose de la polaridad correcta.
Lecturas inexactas o inconsistentes.Sensor not fully warmed up; sensor contamination; low battery.Allow full warm-up time (200 seconds). Ensure sensor head is clean. Replace batteries.
Device constantly alarms in a clean environment.High background gas levels; sensor malfunction.Move to a well-ventilated area to check if the alarm stops. If the issue persists, contact customer support.
No hay alarma cuando hay gas.Gas concentration below alarm threshold; device malfunction.Ensure gas concentration is sufficient to trigger an alarm (2% LEL for yellow, 10% LEL for red). Test with a known gas source if safe to do so. Contact customer support if malfunction is suspected.

9. Especificaciones

Gases de detecciónNatural Gas (NG), Methane, Propane, Butane
Tipo de sensorCatalytic Method Gas Sensor
Tiempo de calentamientoEn 200 segundos
Rango de detección0 ~ 9999ppm
Resolución100 ppm
LED de alarmaThree colors (Green, Yellow, Red)
Umbrales de alarmaYellow LED: ~2% LEL; Red LED: ~10% LEL
Alarma audible2.713kHz / 100ms
Temperatura de trabajo-20 °C ~ 70 °C (-4 °F ~ 158 °F)
Humedad de trabajoMenos del 90% de humedad relativa
Fuente de poder2 pilas AA de 1.5 V (no incluidas)
Dimensiones (L x An x Al)220 x 20 x 20 mm (8.66" x 0.79" x 0.79")
PesoAprox. 80 g (2.82 onzas)

10. Garantía y soporte

For warranty information or technical support, please contact PerfectPrime customer service. Refer to the product packaging or the official PerfectPrime webSitio para obtener los datos de contacto más actualizados.

Websitio: www.perfectprime.com

Documentos relacionados - GA0080

Preview Manual de instrucciones del manómetro digital PerfectPrime AR168
Manual de instrucciones para el manómetro digital PerfectPrime AR168, que incluye introducción al producto, funciones básicas, rendimiento técnico, rangos de medición, definiciones de símbolos, funcionamiento de los botones, precauciones e información adicional.
Preview Guía del protocolo de interfaz USB PerfectPrime TC0520
Una guía completa del protocolo de interfaz USB para el termómetro registrador de datos PerfectPrime TC0520, que detalla los comandos, la salida de datos y la comprobación de errores.
Preview PerfectPrime TC0580 Thermocouple Temperature Data Logger Instruction Manual
This instruction manual provides comprehensive guidance on the PerfectPrime TC0580 Thermocouple Temperature Data Logger. It covers product features, specifications, software installation, device operation, data logging, viewing, exporting, and troubleshooting.