DAB 60161182

Manual del usuario del sistema de refuerzo de agua DAB E.SYBOX 230V

Modelo: 60161182

1. Introducción

The DAB E.SYBOX is an integrated electronic water booster system designed for domestic and residential applications. This system provides constant water pressure while optimizing energy consumption. It is suitable for use with potable water in domestic plants, for gardening, and irrigation. The E.SYBOX can also be used to create groups of up to four pumps.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your E.SYBOX system. Please read it thoroughly before installation and keep it for future reference.

2. Información de seguridad

WARNING: Before performing any operation on the pump, disconnect it from the main power supply.

  • Asegúrese de que la fuente de alimentación voltage matches the specifications of the E.SYBOX (230V).
  • La instalación y el mantenimiento sólo deben ser realizados por personal calificado.
  • Do not operate the pump with flammable or explosive liquids.
  • Proteja la unidad de temperaturas bajo cero.
  • Asegure una ventilación adecuada alrededor de la unidad para evitar el sobrecalentamiento.
  • La unidad debe estar correctamente conectada a tierra.

3. Contenido del paquete

Verifique que todos los componentes estén presentes y sin daños al desembalarlo:

  • DAB E.SYBOX Water Booster System Unit
  • Cable de alimentación
  • Connection Pieces (e.g., 1" plastic unions)
  • Manual de usuario (este documento)

4. Configuración e instalación

The E.SYBOX is designed for straightforward installation and requires no additional components for basic setup. It can be installed either vertically or horizontally.

4.1. Elección de la ubicación de instalación

Seleccione una ubicación que sea:

  • Protected from direct sunlight and extreme temperatures.
  • In a closed space without a high level of air exchange, as the unit is water-cooled and quiet.
  • Accesible para mantenimiento.
  • Near the water source and the distribution system.

4.2. Instalación Física

  1. Colocación de la unidad: Place the E.SYBOX on a stable, level surface. The anti-vibration feet help reduce noise. The unit can be positioned vertically or horizontally.
  2. DAB E.SYBOX Water Booster System, front view

    Figura 1: Frente view of the DAB E.SYBOX unit, showing the display and general form factor.

  3. Conexión de líneas de agua: Connect the inlet pipe from your water source to the suction port and the outlet pipe to your distribution system. Use the provided 1" plastic unions for secure connections. Ensure all connections are watertight.
  4. DAB E.SYBOX Water Booster System, rear view con conexiones

    Figura 2: Posterior view of the E.SYBOX, highlighting the water inlet and outlet connections.

  5. Conexión eléctrica: Connect the power cord to a grounded 230V AC outlet. Ensure the power supply is stable and protected from surges.
  6. Priming the Pump (if necessary): For initial startup or after maintenance, ensure the pump is filled with water before operation to prevent dry running. Refer to the display for priming instructions.

5. Instrucciones de funcionamiento

The E.SYBOX features an adjustable, high-resolution LCD display for easy operation and monitoring.

5.1. Encendido inicial

  1. Once connected to power, the LCD display will illuminate.
  2. Follow the on-screen prompts for initial setup, which may include language selection and basic pressure settings.

5.2. Ajuste de la presión deseada

The E.SYBOX allows you to set your desired water pressure. The system will then maintain this constant pressure by adjusting pump speed.

  • Navigate through the LCD menu using the control buttons adjacent to the display.
  • Locate the "Pressure Setting" option.
  • Adjust the pressure value (e.g., in PSI or Bar) to your preference. The system can deliver up to 210 ft (approx. 90 PSI) of head.
  • Confirm your selection. The system will automatically adjust to maintain this pressure.
DAB E.SYBOX Water Booster System with power and flow specifications

Figure 3: E.SYBOX display showing operational parameters such as power consumption (360W), pressure (3 Bar / 43 PSI), and flow rate (3.2 GPM / 12 l/min).

5.3. Supervisión del rendimiento

The LCD display provides real-time statistics:

  • Presión: Current system pressure.
  • Caudal: Instantaneous water flow.
  • Consumo de energía: Energy consumption of the unit.
  • Alarmas/Advertencias: Notifications for any operational issues.

6. Mantenimiento

Regular maintenance ensures the longevity and optimal performance of your E.SYBOX system.

6.1. Controles de rutina

  • Inspección visual: Periodically check for any leaks, unusual noises, or visible damage.
  • Air Exchange: Ensure the area around the unit is not obstructed to allow for proper air circulation for the water-cooled motor.

6.2. Limpieza del sensor

Over time, sediment may accumulate and affect the flow sensors. The E.SYBOX comes with a tool for cleaning these sensors.

  1. Desconectar la energía: Always disconnect the unit from the power supply before any maintenance.
  2. Locate Sensors: Refer to the detailed diagram in the full technical manual (if available) to locate the flow sensors.
  3. Limpio: Use the provided tool to carefully clean any accumulated sediment from the sensors.
  4. Vuelva a conectar: Reassemble any removed parts and reconnect power.

6.3. Preparación para el invierno

If the unit is installed in an area subject to freezing temperatures, it must be drained to prevent damage.

  • Desconecte la energía.
  • Drain all water from the pump and associated piping.
  • Store in a frost-free environment if possible, or ensure complete drainage.

7. Solución de problemas

This section addresses common issues you might encounter with your E.SYBOX system.

ProblemaPosible causaSolución
No water flow / Pump not startingNo power; Air in pump; Clogged inlet; Low water level in source.Check power connection; Prime the pump; Clean inlet filter; Ensure adequate water supply.
Baja presiónIncorrect pressure setting; Partially clogged filter/pipes; Air in system.Adjust pressure setting on LCD; Inspect and clean filters/pipes; Bleed air from system.
Pump runs continuously / Frequent on/off cyclingLeak in system; Small continuous flow (e.g., dripping faucet); Faulty sensor.Check for leaks in plumbing; Address small continuous flows; Contact support if sensor is suspected.
Ruido o vibración inusualAir in pump; Loose connections; Foreign object in pump.Prime the pump; Check and tighten all connections; Disconnect power and inspect pump impeller (if safe and accessible).
LCD display error messageFallo específico del sistema.Note the error code and consult the full technical manual or contact customer support.

Si el problema persiste después de intentar estas soluciones, comuníquese con el servicio de atención al cliente.

8. Especificaciones

CaracterísticaDetalle
Modelo60161182
Volumentage230 voltios
Fuente de poderAC/DC
Caudal máximo32 galones por minuto (GPM)
Altura máxima de elevación (cabeza)210 pies
Rango de temperatura del líquido+32 to +95°F (domestic use), +32 to +102°F (other uses)
Profundidad máxima de succión26 pies
Peso del artículo57 libras
Dimensiones del producto (L x An x Al)14.25 x 10.35 x 22.2 pulgadas
Materialabdominales
Integrated Expansion Tank0.5 galones

9. Garantía y soporte

9.1. Información de garantía

DAB provides a limited warranty for the E.SYBOX 230V Water Booster System against defects in materials and workmanship under normal use and service. The specific duration and terms of the warranty may vary by region and purchase date. Please retain your proof of purchase for warranty claims.

For detailed warranty terms and conditions, refer to the warranty card included with your product or visit the official DAB websitio.

9.2. Atención al cliente

If you require technical assistance, have questions about installation, operation, or maintenance, or need to report a problem, please contact DAB customer support.

  • Soporte en línea: Visit the official DAB Pumps website for FAQs, technical documents, and contact forms.
  • Soporte telefónico: Refer to the contact information provided on the DAB websitio o el embalaje de su producto para obtener números de soporte regional.
  • When contacting support, please have your product model (60161182) and serial number (if applicable) ready.

Documentos relacionados - 60161182

Preview DAB Esybox Mini 3 Quick Installation Guide
A concise guide for the quick installation of the DAB Esybox Mini 3 variable speed booster pump, covering setup, connections, and initial operation.
Preview Esybox Mini³: Manual de instalación y mantenimiento
Guía completa de instalación, configuración y mantenimiento del sistema de bomba Esybox Mini³ de DAB Water Technology.
Preview DAB Esybox Pop Sistema electrónico de presión - Datos técnicos y funciones
Información detalladatagvinculado al DAB Esybox Pop, un sistema electrónico de presión para uso residencial, que incluye técnicas específicas, gráficos de prestación, funciones del servicio digital H₂D y accesorios.
Preview Guía de inicio rápido de la bomba sumergible seca DAB Pulsar
Guía concisa para instalar y operar la bomba sumergible DAB Pulsar Dry, incluidas especificaciones técnicas, precauciones de seguridad y detalles de conexión.
Preview DAB E.SYTANK: Tanque de almacenamiento de agua potable. Finalizado.view
Explore el DAB E.SYTANK, un tanque de almacenamiento de agua potable diseñado para un suministro de agua eficiente en aplicaciones residenciales y comerciales ligeras, a menudo integrado con el sistema de bomba de refuerzo E.SYBOX.
Preview Controles y configuraciones del receptor de radio digital DAB
Una guía de los controles y configuraciones de un receptor de radio digital DAB, incluida la selección de estaciones, listas de canales, funciones de búsqueda y preferencias del sistema.