1. Introducción
This manual provides essential information for the installation, operation, and maintenance of your Vaillant ECOTEC PURE VMW 246/7-2 condensing boiler. Please read this manual thoroughly before attempting any installation or operation to ensure safe and efficient use of the appliance.
The Vaillant ECOTEC PURE VMW 246/7-2 is a methane-powered condensing boiler designed for both central heating and instantaneous domestic hot water production. It features an intuitive user interface, a high-efficiency modulating pump, and a durable primary steel exchanger.

Figura 1: Frente view of the Vaillant ECOTEC PURE VMW 246/7-2 condensing boiler. The unit is white with the Vaillant logo prominently displayed. A digital display shows '50' and control buttons are visible below it.
2. Instrucciones de seguridad
Importante: Failure to follow these safety instructions could result in property damage, personal injury, or death. Keep this manual in a safe place for future reference.
- Installation and maintenance must only be carried out by a qualified and certified technician in accordance with local regulations and standards.
- No almacene materiales inflamables cerca de la caldera.
- Asegúrese de que haya una ventilación adecuada en la habitación donde está instalada la caldera.
- If you smell gas, immediately shut off the gas supply, open windows and doors, and contact a qualified technician. Do not operate any electrical switches.
- No lo hagasamper with the boiler's internal components.
- Mantenga a los niños y las mascotas alejados del aparato.
3. Instalación y configuración
3.1 Comprobaciones previas a la instalación
- Verify that the gas supply type (methane) matches the boiler's requirements.
- Ensure the installation site meets all local building codes and ventilation requirements.
- Confirm that the electrical supply is compatible with the boiler's specifications.
- Unpack the boiler carefully and inspect for any shipping damage.
3.2 Montaje de la caldera
- Select a suitable wall location capable of supporting the boiler's weight (approximately 20 kg).
- Use the provided mounting template (if applicable) to mark drilling points for the wall bracket.
- Securely fasten the wall bracket to the wall using appropriate fixings.
- Carefully lift and hang the boiler onto the wall bracket.
3.3 Conexión de utilidades
- Conexión de gas: Connect the methane gas supply line to the boiler's gas inlet, ensuring all connections are gas-tight and tested for leaks.
- Conexiones de agua: Connect the central heating flow and return pipes, and the domestic hot water inlet and outlet pipes. Ensure proper isolation valves are installed.
- Drenaje condensado: Connect the condensate drain line to an appropriate waste system, ensuring a continuous downward slope.
- Sistema de humos: Install the flue system according to manufacturer instructions and local regulations for safe exhaust gas discharge.
- Conexión eléctrica: Conecte la caldera a la red eléctrica, asegurándose de que exista una adecuada conexión a tierra y protección del circuito.
3.4 Initial Filling and Venting
- Fill the heating system with water to the recommended pressure (typically 1.0-1.5 bar), monitoring the pressure gauge.
- Vent all radiators and the boiler itself to remove air from the system.
- Check for any leaks in the entire system.
4. Instrucciones de funcionamiento
4.1 Interfaz de usuario Terminadaview
The ECOTEC PURE VMW 246/7-2 features an intuitive user interface with a digital display and control buttons. The display shows current operating status, temperature settings, and error codes.
- Pantalla digital: Shows temperature, pressure, and status codes.
- Botón de modo: Toggles between heating, hot water, or standby modes.
- Botones de ajuste de temperatura (+/-): Used to increase or decrease desired heating or hot water temperatures.
- Botón de reinicio: Used to clear certain error codes after rectifying the fault.
4.2 Puesta en marcha de la caldera
- Asegúrese de que el suministro de gas esté abierto y el suministro eléctrico esté conectado.
- Check that the system pressure is within the recommended range (1.0-1.5 bar).
- Press the power button (if present) or ensure the boiler is switched on at the mains.
- Select the desired operating mode (e.g., heating and hot water).
- Set the desired heating and hot water temperatures using the adjustment buttons.
4.3 Connecting a VSMART Thermostat
The Vaillant ECOTEC PURE VMW 246/7-2 is compatible with the Vaillant VSMART thermostat for enhanced control and energy efficiency. Refer to the VSMART thermostat's separate instruction manual for detailed pairing and operation instructions.
5. Mantenimiento
Regular maintenance is crucial for the safe, efficient, and long-lasting operation of your Vaillant boiler. Only qualified technicians should perform maintenance tasks.
5.1 Mantenimiento anual
- It is recommended to have your boiler serviced annually by a Vaillant-certified technician.
- Annual servicing includes checking combustion efficiency, gas pressure, safety devices, and cleaning internal components.
5.2 Comprobaciones del usuario
- Presión del sistema: Regularly check the system pressure on the boiler's display. If it falls below 1.0 bar, repressurize the system according to the instructions in Section 3.4 or consult a technician.
- Inspección visual: Periodically inspect the boiler for any visible leaks, unusual noises, or changes in performance.
- Drenaje condensado: Ensure the condensate drain is clear and not blocked.
6. Solución de problemas
This section provides solutions to common issues. For complex problems or if an error persists, contact a qualified service technician.
| Problema | Posible causa | Solución |
|---|---|---|
| Sin calefacción ni agua caliente | Baja presión del sistema, sin suministro de gas, corte de energíatage, thermostat setting too low. | Check system pressure and repressurize if needed. Ensure gas valve is open. Check electrical supply. Adjust thermostat settings. |
| Caldera que muestra un código de error | Various internal faults. | Note the error code and consult the full technical manual or contact a qualified technician. Try pressing the Reset button once. |
| Unusual noises from the boiler | Aire en el sistema, problema con la bomba, acumulación de cal. | Vent radiators. If noise persists, contact a qualified technician. |
| Fuga de agua | Conexión suelta, componente defectuoso. | Cierre inmediatamente el suministro de agua a la caldera y póngase en contacto con un técnico calificado. |
| Pilot light (if applicable) not igniting | No gas supply, ignition fault. | Verifique el suministro de gas. Si el problema persiste, contacte con un técnico calificado. |
| Reduced hot water flow or temperature | Limescale buildup, faulty sensor, low water pressure. | Check water pressure. Contact a qualified technician for inspection and descaling if necessary. |
7. Especificaciones técnicas
| Característica | Especificación |
|---|---|
| Modelo | ECOTEC PURE VMW 246/7-2 |
| Número de pieza | 0010019985 |
| Marca | Vaillant |
| Tipo de combustible | Metano (Gas Natural) |
| Salida de calefacción | 24 kW |
| Domestic Hot Water Output | 28 kW (Instantaneous) |
| Tipo de bomba | Modulating 1:4 (Class A) |
| Primary Exchanger Material | Acero |
| Capacidad del vaso de expansión | 8 litros |
| Dimensiones (alto x ancho x profundidad) | 80 cm x 50 cm x 40 cm (aproximado) |
| Peso | 20 kilogramos |
| Clasificación de eficiencia energética | A |
| Compatibilidad | VSMART Thermostat |
8. Garantía y soporte
8.1 Información de garantía
Vaillant products are covered by a manufacturer's warranty. The specific terms and duration of the warranty may vary by region and purchase date. Please refer to the warranty card included with your product or visit the official Vaillant websitio para obtener información detallada.
Nota: Improper installation, unauthorized repairs, or failure to perform regular maintenance may void your warranty.
8.2 Soporte técnico
For technical assistance, spare parts, or to schedule a service appointment, please contact your local Vaillant service center or authorized dealer. Contact details can typically be found on the Vaillant official websitio web o en la documentación de su producto.
When contacting support, please have your boiler's model number (VMW 246/7-2) and part number (0010019985) readily available.