1. Introducción

This manual provides essential information for the safe and efficient use of the Delfield 2160045 Axial Ebm 115 Volt Fan. Please read these instructions thoroughly before installation, operation, or maintenance to ensure proper function and longevity of the unit. This fan is a genuine OEM replacement part from Delfield, designed for industrial and scientific applications, particularly as a cooling component.

Producto terminadoview

The Delfield 2160045 is an axial fan operating at 115 Volts, designed for cooling purposes. Key features include:

Delfield 2160045 Axial Ebm 115 Volt Fan, front view con etiqueta

Figura 1.1: Frente view of the Delfield 2160045 Axial Ebm 115 Volt Fan, showing the fan blades and the manufacturer's label. The label indicates model EC12038BH0HT-01-002, 100-120V/220-240V AC, 50/60Hz, 15W, and part number 21600451804633149004.

2. Información de seguridad

Observe siempre las siguientes precauciones de seguridad para evitar lesiones o daños al producto.

3. Configuración e instalación

This section outlines the general steps for installing the Delfield 2160045 Axial Ebm 115 Volt Fan.

  1. Desembalaje: Carefully remove the fan from its packaging. Inspect for any signs of damage during transit.
  2. Ubicación de montaje: Select a suitable mounting location that allows for adequate airflow and is free from obstructions. Ensure the surface can support the fan's weight.
  3. Montaje del ventilador:
    • Align the fan with the mounting holes on the equipment or enclosure.
    • Secure the fan using appropriate screws or fasteners (not included). Ensure the fan is mounted firmly to prevent vibration.
  4. Conexión eléctrica:
    • Asegúrese de que la fuente de alimentación esté desconectada antes de realizar cualquier conexión eléctrica.
    • Connect the fan's power connector (3-Pin, 4-Pin, or SATA/Molex, depending on the specific unit and application) to the corresponding power source.
    • Verificar que el voltage matches the fan's requirements (115 Volts AC).
    • Asegúrese de que todas las conexiones estén seguras y aisladas.
  5. Dirección del flujo de aire: Confirm the desired airflow direction before final installation. Axial fans typically have an arrow indicating airflow direction on the housing.
Delfield 2160045 Axial Ebm 115 Volt Fan, side view

Figura 3.1: Lado view of the Delfield 2160045 fan, illustrating its compact design and mounting points.

4. Instrucciones de funcionamiento

Once installed, operating the Delfield 2160045 fan is straightforward.

  1. Encendido: After ensuring all connections are secure and safe, restore power to the system or equipment where the fan is installed.
  2. Comprobación inicial: Observe the fan for proper rotation and listen for any unusual noises. The fan should operate smoothly.
  3. Operación continua: The fan is designed for continuous operation to provide consistent airflow and cooling.
  4. Escucha: Periodically check the fan's performance to ensure it is effectively cooling the intended area.

5. Mantenimiento

Regular maintenance ensures optimal performance and extends the lifespan of your Delfield 2160045 fan.

Delfield 2160045 Axial Ebm 115 Volt Fan, rear view

Figura 5.1: Trasero view of the Delfield 2160045 fan, showing the motor housing and structural elements.

6. Solución de problemas

Consulte la siguiente tabla para conocer los problemas comunes y sus posibles soluciones.

ProblemaPosible causaSolución
El ventilador no arrancaNo power supply; Loose electrical connection; Damaged fan motorCheck power source; Secure all connections; Replace fan if motor is damaged
El ventilador hace un ruido inusualObstruction in fan blades; Loose mounting; Worn bearingsDisconnect power and remove obstruction; Tighten mounting screws; Replace fan if bearings are worn
Flujo de aire reducidoDust accumulation on blades; Obstruction in airflow pathClean fan blades and housing; Remove any obstructions

Si el problema persiste después de intentar estas soluciones, comuníquese con personal de servicio calificado.

7. Especificaciones

Detailed technical specifications for the Delfield 2160045 Axial Ebm 115 Volt Fan:

8. Garantía y soporte

Specific warranty information for the Delfield 2160045 Axial Ebm 115 Volt Fan is typically provided at the point of purchase or with the product packaging. As this is a genuine OEM replacement part, warranty terms may be subject to the original equipment manufacturer's policies.

For technical support, replacement parts, or warranty claims, please contact your authorized Delfield dealer or the supplier from whom the product was purchased. Ensure you have the model number (2160045) and purchase details available when contacting support.

Documentos relacionados - 2160045

Preview Delfield DSL Pass-Thru Series DSLFPT Original Parts List
This document provides the original parts list for the Delfield DSL Pass-Thru Series DSLFPT model. It includes part numbers, full descriptions, and notes for service and cross-referencing older part numbers with new ones.
Preview Delfield F14 Hot Food Tables Parts List
Original parts list for Delfield F14 Hot Food Tables models F14EW232, F14EW348, F14EW460, F14EW572, and F14EW688, covering parts from 01/2007 to current. Includes part numbers, descriptions, and notes for maintenance and service.
Preview Delfield F14 Hot Food Tables Parts List
Original parts list for Delfield F14 Hot Food Tables, including models F14EI232, F14EI348, F14EI460, F14EI572, and F14EI688. Details part numbers, descriptions, and notes for maintenance and repair.
Preview Delfield GCF2P, GBF2P, GBSF2P R290 Series Parts List
Original parts list for Delfield GCF2P, GBF2P, and GBSF2P R290 series commercial refrigeration units. Includes part numbers, descriptions, and revision notes for various components.
Preview Delfield F14 Hot Food Tables Parts List with DFW Thermostatic Control
This document provides the original parts list for the Delfield F14 Hot Food Tables equipped with DFW Thermostatic Control, covering models from 01/2007 to the current date. It includes detailed part numbers, descriptions, and an exploded view diagram for easy identification and replacement.
Preview Guía de programación del temporizador de descongelación AIR-O-TRONICS
Guía del usuario del temporizador de descongelación AIR-O-TRONICS, que detalla la configuración de los interruptores DIP para la duración de la descongelación y el tiempo del ciclo, con secuencias operativas e información de cableado.