Introducción
This manual provides essential information for the safe and effective installation, operation, and maintenance of your SCHELINGER A51-SPD01-4P-B+C CCS Surge Protector. Please read this manual thoroughly before use and retain it for future reference.
The SCHELINGER A51-SPD01-4P-B+C CCS Surge Protector is designed to protect electrical installations from transient overvoltages caused by lightning strikes or switching operations. It features a fast response time and high stability to ensure reliable protection for your electrical systems.
Instrucciones de seguridad
ADVERTENCIA: Electrical installations should only be performed by qualified personnel. Failure to follow these instructions can result in electric shock, fire, or serious injury.
- Always disconnect power to the circuit before installing or servicing the surge protector.
- Asegúrese de que la conexión a tierra sea adecuada según los códigos eléctricos locales y nacionales.
- No opere el dispositivo si parece dañado.
- Mantenga el dispositivo alejado de la humedad y temperaturas extremas.
- Este dispositivo está diseñado para uso en interiores en ambientes secos a menos que se especifique lo contrario.
Contenido del paquete
Verifique que todos los componentes estén presentes en el paquete:
- 1 x SCHELINGER A51-SPD01-4P-B+C CCS Surge Protector (4P 5kA class T1+T2 (B+C))
- 1 x Manual de usuario (este documento)
Configuración e instalación
The SCHELINGER A51-SPD01-4P-B+C surge protector is designed for mounting on a standard 35 mm DIN rail within an electrical distribution board.
- Desconexión de energía: Before beginning installation, ensure that the main power supply to the electrical panel is completely disconnected and locked out to prevent accidental re-energization.
- Montaje: Snap the surge protector onto the 35 mm DIN rail. Ensure it is securely fastened.
- Alambrado: Connect the surge protector according to the wiring diagram provided in your electrical panel documentation or by a qualified electrician. Ensure correct phase, neutral, and ground connections. The device is a 4-pole protector.
- Toma de tierra: Verify that the grounding connection is robust and compliant with all applicable electrical codes. Proper grounding is critical for effective surge protection.
- Inspección: After wiring, visually inspect all connections to ensure they are tight and correct.
- Restauración de energía: Una vez completada y verificada la instalación, restablezca la energía al panel eléctrico.
Image: The SCHELINGER A51-SPD01-4P-B+C CCS Surge Protector, typically installed on a DIN rail within an electrical panel. This image shows the device's compact form factor and connection terminals.
Instrucciones de funcionamiento
The SCHELINGER A51-SPD01-4P-B+C is an automatic surge protection device. Once correctly installed and powered, it operates continuously to protect your electrical system from transient overvoltages. There are no user-adjustable settings or controls.
- Indicador de estado: The device typically includes a visual indicator (e.g., a green/red flag or LED) to show its operational status. A green indicator usually signifies normal operation, while a red indicator or absence of light may indicate that the protection module has been activated and needs replacement. Refer to the device's specific markings for indicator interpretation.
- Protección automática: The device automatically diverts excess voltage to the ground, protecting connected equipment.
Mantenimiento
Regular inspection of the surge protector is recommended to ensure its continued effectiveness.
- Inspección visual: Periodically check the status indicator on the device. If the indicator shows a fault (e.g., red flag), the protection module has likely absorbed a significant surge and requires replacement.
- Limpieza: Mantenga el dispositivo libre de polvo y residuos. Utilice un paño seco y suave para limpiarlo. No utilice limpiadores líquidos.
- Control profesional: It is advisable to have a qualified electrician inspect your electrical system, including surge protection devices, during routine electrical maintenance.
Solución de problemas
If you suspect an issue with your surge protector, consider the following:
- No Power to Protected Devices:
- Check the main circuit breaker for the electrical panel.
- Verify that the surge protector's status indicator is green (operational). If it's red, the module may need replacement.
- Asegúrese de que todas las conexiones del cableado sean seguras.
- Frequent Tripping of Circuit Breakers:
- This could indicate a fault in the electrical system or that the surge protector has been repeatedly exposed to surges. Consult a qualified electrician.
- Surge Protector Indicator is Red:
- This indicates that the surge protector has absorbed a significant overvoltage event and its protective elements are exhausted. The module requires replacement to restore protection. Contact a qualified electrician for replacement.
For issues not resolved by these steps, contact a qualified electrician or SCHELINGER customer support.
Presupuesto
| Número de modelo | A51-SPD01-4P-B+C |
| Clase de protección | B + C (Type 1 + Type 2) |
| Highest Operating Voltagmi (Uc) | 275 V CA |
| Corriente de impulso (Iimp) | 5 kA |
| Corriente de descarga nominal (In) | 10 kA |
| Corriente máxima de descarga (Imax) | 50 kA |
| Número de polos | 4P |
| Montaje | 35 mm DIN Rail |
| Temperatura de funcionamiento | -40 °C a +80 °C |
| Cumplimiento | EN 61643-11 |
| Fabricante | BEMKO SP. ZOO |
| Dimensiones del producto (L x An x Al) | 6.5 x 7.2 x 9 cm |
| Peso | 380 gramos |
| Material | Plástico |
| Color | Blanco |
Garantía y soporte
For warranty information and technical support, please refer to the documentation provided with your purchase or contact SCHELINGER customer service through their official webSitio web o distribuidores autorizados. Conserve su recibo de compra como comprobante.
Fabricante: BEMKO SP. ZOO
Referencia del modelo: A51-SPD01-4P-B+C