This manual provides essential information for the safe installation, operation, and maintenance of your Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light. Please read these instructions thoroughly before installation and use, and retain them for future reference.
The Akicon BPT16-14EL-L12 exhaust fan is designed to effectively remove moisture and odors from bathrooms and similar indoor spaces up to 85 square feet. It features a quiet operation at 1.5 sones and an integrated 12W LED light for illumination.

Descripción de la imagen: Un lado frontal view of the Akicon BPT16-14EL-L12 bathroom exhaust fan, showcasing its white grille cover with integrated LED light and the metal housing with a black duct connector.
Información de seguridad
ADVERTENCIA: Para reducir el riesgo de incendio, descarga eléctrica o lesiones a las personas, observe lo siguiente:
- El trabajo de instalación y el cableado eléctrico deben ser realizados por personas calificadas de acuerdo con todos los códigos y estándares aplicables, incluidos los códigos y estándares de construcción con clasificación contra incendios.
- Desconecte siempre la alimentación en el panel de servicio antes de cablear o realizar mantenimiento a la unidad.
- This unit is HVI-certified and cUL listed for use over bathtubs and showers when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
- No utilice este ventilador con ningún dispositivo de control de velocidad de estado sólido.
- Never place any object into the fan blades.
- Asegúrese de que el ventilador esté correctamente conectado a tierra.
- Duct work must be installed with a minimum number of turns and runs to ensure optimal airflow.
Contenido del paquete
Verifique que todos los componentes estén presentes antes de comenzar la instalación:
- Exhaust Fan Housing Assembly
- Grille Cover with Integrated LED Light
- 12W E26 Base LED Bulb (pre-installed or separate)
- Installation Hardware (screws, wire connectors)
- Manual de usuario (este documento)
Presupuesto
| Característica | Especificación |
|---|---|
| Marca | Akicon |
| Número de modelo | BPT16-14EL-L12 |
| Capacidad de flujo de aire | 90 pies cúbicos por minuto (CFM) |
| Nivel de ruido | 1.5 Sonios |
| Fuente de poder | AC |
| Volumentage | 120 voltios |
| Lámpara LED Wattage | 12 vatios |
| Temperatura de color de la luz LED | 5000K (blanco frío) |
| Dimensiones de la carcasa (largo x ancho x alto) | 9-3/8" x 9-3/8" x 7-5/16" |
| Grille Cover Size | 11" x 11" |
| Tamaño del conducto | 4 pulgadas redondas |
| Tamaño de habitación recomendado | Hasta 85 pies cuadrados. |
| Certificaciones | HVI, cUL Listed |
| Peso del artículo | 8.83 libras |
Configuración e instalación
This section outlines the general steps for installing the Akicon BPT16-14EL-L12 exhaust fan. For detailed diagrams and specific instructions, refer to the included installation guide or consult a qualified electrician.
1. Consideraciones previas a la instalación
- Measure Room Size: Ensure the fan's 90 CFM capacity is suitable for your room (up to 85 sq. ft.).
- Apertura del techo: The recommended ceiling opening size is approximately 9-7/8" x 9-7/8". If replacing an existing fan, measure the current opening. If the existing opening is smaller, it will need to be enlarged to accommodate the new housing.
- Conductos: Plan for a 4-inch round duct connection. Use rigid metal ducting for best performance.
- Cableado eléctrico: Ensure a 120V AC power supply is available. The fan and light can be wired to operate jointly or separately via wall switches.

Descripción de la imagen: This image displays the critical dimensions for installation. It shows the fan housing size as 9-3/8" x 9-3/8" x 7-5/16", the grille cover size as 11" x 11", and the recommended ceiling opening size as 9-7/8" x 9-7/8". This helps ensure proper fit during installation.

Descripción de la imagen: An installation notice highlighting the housing dimensions (9.4" x 9.4" x 7.7") and emphasizing that the opening hole size should be based on the housing size. It advises checking existing opening sizes for replacements and cutting the hole to match the new housing if necessary.
2. Mounting the Fan Housing
- Apague la energía en el disyuntor.
- Cut the ceiling opening to the specified dimensions (approx. 9-7/8" x 9-7/8").
- Secure the fan housing to ceiling joists using appropriate fasteners. The housing is designed for screw-in installation. Ensure it is firmly attached to prevent vibration and noise.

Descripción de la imagen: This diagram shows two common installation scenarios: attic and soffit. It illustrates how the fan can be ducted to exhaust air outside, emphasizing the importance of proper ducting for effective ventilation.
3. Conexión de conductos
- Connect a 4-inch round duct to the fan's exhaust collar. Secure with duct tape or clamps.
- Route the duct to an exterior vent cap, ensuring minimal bends and a slight downward slope away from the fan to prevent condensation buildup.

Descripción de la imagen: A comprehensive installation diagram showing the fan housing, duct connection, and electrical wiring points. It provides a visual guide for the step-by-step installation process within a ceiling.
4. Cableado eléctrico
- Open the wiring compartment on the fan housing.
- Connect the household wiring to the fan's wiring according to local electrical codes. The fan and light have separate wires, allowing for independent operation if desired (e.g., separate wall switches for fan and light).
- Ensure all connections are secure and properly insulated. Close the wiring compartment cover.
5. Install Grille Cover
- If the LED bulb is not pre-installed, screw the 12W E26 base LED bulb into the socket.
- Attach the grille cover to the fan housing. Typically, this involves inserting mounting springs into slots in the housing and pushing the grille firmly against the ceiling.
Una vez completada la instalación, restablezca la energía en el disyuntor y pruebe las funciones del ventilador y la luz.
Instrucciones de funcionamiento
The Akicon BPT16-14EL-L12 exhaust fan and LED light are designed for simple operation via standard wall switches.
- Operación del ventilador: Flip the designated wall switch to turn the exhaust fan ON or OFF.
- Operación ligera: Flip the designated wall switch to turn the LED light ON or OFF.
- If wired separately, the fan and light can be controlled independently. If wired jointly, both will activate simultaneously.
For optimal moisture and odor removal, operate the fan during and after showering or bathing for at least 15-20 minutes.
Mantenimiento
Regular maintenance ensures optimal performance and longevity of your exhaust fan. Always disconnect power at the circuit breaker before performing any maintenance.
1. Cleaning the Grille Cover
- Tire suavemente hacia abajo la cubierta de la rejilla para separarla de los resortes de la carcasa.
- Wash the grille cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.

Descripción de la imagen: Un detallado view of the fan's white grille cover, showing the ventilation slots and the central LED light panel. This component is easily removable for cleaning.
2. Cleaning the Fan Interior
- With the grille removed and power off, carefully wipe down the fan blades and interior of the housing with a damp paño.
- Do not allow water to enter the motor or electrical components.
- Asegúrese de que todas las piezas estén secas antes de restablecer la energía.
3. LED Bulb Replacement
- Asegúrese de que la energía esté apagada.
- Remove the grille cover.
- Unscrew the old E26 base LED bulb and replace it with a new 12W E26 base LED bulb.
- Reattach the grille cover and restore power.
Solución de problemas
If you encounter issues with your Akicon exhaust fan, refer to the following common problems and solutions:
| Problema | Posible causa | Solución |
|---|---|---|
| El ventilador no funciona / La luz no enciende | No power supply; Loose wiring; Faulty switch; Blown fuse/tripped breaker | Check power at the circuit breaker. Ensure all wiring connections are secure. Test the wall switch. Replace fuse or reset breaker. |
| El ventilador es excesivamente ruidoso | Loose mounting; Obstruction in fan blades; Dirty fan blades/motor; Improper ducting | Ensure fan housing is securely mounted. Disconnect power and check for obstructions. Clean fan blades and motor. Inspect ductwork for kinks or blockages. |
| Bajo rendimiento de ventilación | Ducting issues (too long, too many bends, wrong size); Blocked exterior vent; Room size exceeds fan capacity | Inspect ductwork for proper installation and clear any blockages. Ensure exterior vent is clear. Verify fan CFM matches room size. |
| La luz LED parpadea o está tenue | Loose bulb; Faulty bulb; Wiring issue | Ensure bulb is screwed in tightly. Replace the LED bulb. Check electrical connections to the light. |
If the problem persists after attempting these solutions, please contact Akicon customer support.
Información de garantía
The Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light comes with a Garantía limitada de 3 años a partir de la fecha de compra. Esta garantía cubre defectos de materiales y mano de obra en condiciones normales de uso.
The warranty does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repair or modification. Proof of purchase is required for all warranty claims.
Atención al cliente
For any questions, technical assistance, or warranty claims, please contact Akicon customer service. Have your model number (BPT16-14EL-L12) and proof of purchase ready when contacting support.
Contact information can typically be found on the Akicon official websitio o a través de su plataforma de compra.