Stelpro RWF0502W

Manual de instrucciones del calefactor de pared Stelpro Pulsair RWF0502W

Instrucciones de seguridad importantes

Read all instructions before installing or using this heater. Failure to follow these instructions may result in fire, electric shock, serious injury, or death.

Producto terminadoview

The Stelpro pulsair RWF0502W is a 240V wall-mounted fan heater designed for supplemental heating in various rooms such as bedrooms, home offices, and living rooms. It utilizes both convection and forced air heating methods to efficiently distribute warmth.

Frente view of the Stelpro pulsair RWF0502W wall fan heater

Frente view of the Stelpro pulsair RWF0502W wall fan heater, showing the fan grille and lower air outlet.

Dimensions of the Stelpro pulsair RWF0502W wall fan heater

Diagram showing the dimensions of the Stelpro pulsair RWF0502W wall fan heater: 17 1/8 inches (435 mm) height, 8 11/16 inches (220 mm) width, and 3 3/16 inches (80 mm) depth.

Instalación

Lista de verificación previa a la instalación:

Opciones de montaje:

The RWF0502W heater can be either surface-mounted directly to the wall or recessed into the wall for a flush finish. Ensure adequate clearance from floors, ceilings, and adjacent walls as per local codes and manufacturer recommendations.

Stelpro pulsair RWF0502W heater installed in an entryway

The Stelpro pulsair RWF0502W wall fan heater installed in a modern entryway, positioned below a plant and mirror.

Stelpro pulsair RWF0502W heater installed on a blue wall

The Stelpro pulsair RWF0502W wall fan heater installed on a blue wall in an entryway, with coats and shoes nearby.

Conexión eléctrica:

This heater requires a 240V hardwired connection. Follow the wiring diagram provided and ensure all connections are secure and properly insulated. Connect the heater to a dedicated circuit protected by the appropriate circuit breaker.

Wiring diagram for Stelpro pulsair RWF0502W wall fan heater

Diagram illustrating the 240V hardwired connection for the Stelpro pulsair RWF0502W wall fan heater, showing wires connecting within a junction box.

  1. Turn off power at the main electrical panel.
  2. Remove the front grille of the heater to access the wiring compartment.
  3. Connect the supply wires to the heater's terminals according to the wiring diagram. Ensure proper grounding.
  4. Secure all connections with wire nuts and ensure no bare wires are exposed.
  5. Reattach the front grille.
  6. Install the external wall thermostat according to its manufacturer's instructions.

Operación

The Stelpro pulsair RWF0502W heater is controlled by an external wall thermostat (not included). Once installed and wired correctly, follow these steps:

  1. Encendido: Restore power to the heater circuit at the main electrical panel.
  2. Configuración del termostato: Adjust the external thermostat to your desired temperature. The heater will activate when the room temperature falls below the set point.
  3. Operación inicial: During the first few minutes of operation, the heater may emit a slight odor due to the burning off of manufacturing residues. This is normal and will dissipate quickly.
  4. Rango de temperatura: The heater is designed to operate within a temperature range of 5°C (41°F) to 30°C (86°F).

For optimal performance, avoid placing furniture or other obstructions directly in front of the heater's air outlets.

Mantenimiento

Regular maintenance ensures efficient and safe operation of your Stelpro pulsair heater. Always disconnect power at the main circuit breaker before performing any maintenance.

Solución de problemas

If your Stelpro pulsair heater is not operating correctly, consult the following table before contacting customer support.

ProblemaPosible causaSolución
El calentador no enciende.No llega energía a la unidad.
Termostato ajustado demasiado bajo.
Se disparó el disyuntor.
Check main electrical panel.
Aumente el ajuste del termostato.
Restablecer el disyuntor.
El calentador produce calor insuficiente.El tamaño de la habitación es demasiado grande para el calentador.
Airflow obstructed.
Thermostat calibration issue.
Ensure heater is appropriately sized for the room.
Clear obstructions from grilles.
Consult thermostat manual or a qualified electrician.
Ruido inusual durante el funcionamiento.Componentes sueltos.
Debris in fan.
Disconnect power and inspect for loose parts.
Disconnect power and carefully remove any debris. If noise persists, contact support.
El calentador se enciende y se apaga con demasiada frecuencia.Thermostat location or setting.
Protección contra sobrecalentamiento activada.
Relocate thermostat away from drafts or direct heat sources. Adjust thermostat differential.
Ensure grilles are clear and heater is not covered. Allow unit to cool.

Presupuesto

CaracterísticaDetalle
MarcaStelpro
Número de modeloRWF0502W
Tipo de montajeWall Mount (Surface or Recessed)
Tipo de habitaciónDormitorio, oficina en casa, sala de estar
Volumentage240 voltios
Ampanhelo2.08 Amps
Método de calentamientoConvection, Forced Air
Configuración de temperatura mínima5 grados Celsius (41 °F)
Ajuste de temperatura máxima30 grados Celsius (86 °F)
Peso del artículo7 libras
Dimensiones del paquete17.72 x 9.13 x 3.58 pulgadas
Código Postal626296002285

Garantía

Stelpro products are manufactured to high standards and are covered by a limited warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Stelpro webSitio. Conserve su comprobante de compra para reclamaciones de garantía.

Atención al cliente

For technical assistance, replacement parts, or further inquiries, please contact Stelpro customer service. Contact information can typically be found on the product packaging, the official Stelpro website, or by referring to the documentation included with your purchase.

Note: Always provide your product model number (RWF0502W) when contacting support.

Documentos relacionados - RWF0502W

Preview Manual del propietario y guía de instalación del calefactor de pared Stelpro Pulsair RWF
Manual completo del usuario y guía de instalación del calefactor de pared Stelpro Pulsair RWF, que incluye instrucciones de seguridad, procedimientos de instalación, resolución de problemas y mantenimiento. Incluye especificaciones técnicas e información sobre la garantía.
Preview Manual del propietario y guía de instalación del termostato no programable STELPRO ST252NP, ST302NP, ST402NP
Guía completa para la instalación y el funcionamiento de los termostatos electrónicos no programables STELPRO ST252NP, ST302NP y ST402NP para zócalos y convectores. Incluye especificaciones técnicas, características e información sobre la garantía.
Preview Calentadores de gabinete arquitectónicos Stelpro ACW750 y ACW1000: Especificaciones y características
Explore los calefactores arquitectónicos Stelpro ACW750 y ACW1000. Diseñados para una calefacción potente y silenciosa en espacios comerciales y públicos. Este documento detalla características, especificaciones técnicas, accesorios disponibles y planos de instalación.
Preview Manual del propietario del termostato electrónico programable STELPRO ST402PFF
Manual detallado del propietario del termostato electrónico programable STELPRO ST402PFF, que cubre la instalación, programación, características y especificaciones técnicas para calentadores de zócalo, convectores y ventiladores.
Preview Stelpro SWU Series Industrial/Commercial Washdown Electric Unit Heater User's Guide
User's guide for the Stelpro SWU Series Industrial/Commercial Washdown Electric Unit Heater, covering installation, operation, and maintenance.
Preview Stelpro SEU Explosion-Proof Unit Heater Owner's Manual
Owner's manual for the Stelpro SEU series of explosion-proof unit heaters, covering installation, operation, maintenance, and safety information.