Instrucciones de seguridad importantes
Read all instructions before installing or using this heater. Failure to follow these instructions may result in fire, electric shock, serious injury, or death.
- Conexión eléctrica: This heater operates on 240 Volts. All wiring must be performed by a qualified electrician and comply with national and local electrical codes.
- Toma de tierra: Este calentador debe estar conectado a tierra.
- Ubicación: Do not install the heater near flammable materials, in areas where gasoline, paint, or other flammable liquids are stored, or where explosive dust is present. Maintain minimum clearances from walls and other objects as specified in the installation section.
- Supervisión: Close supervision is necessary when any heater is used by or near children or invalids, and whenever the heater is left operating and unattended.
- Calentamiento excesivo: To avoid overheating, do not cover the heater. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
- Mantenimiento: Disconnect power at the main service panel before performing any maintenance or cleaning.
- Termostato: A separate thermostat is required for operation and is sold separately. Ensure the thermostat is compatible with a fan-forced heater.
Producto terminadoview
The Stelpro pulsair RWF0502W is a 240V wall-mounted fan heater designed for supplemental heating in various rooms such as bedrooms, home offices, and living rooms. It utilizes both convection and forced air heating methods to efficiently distribute warmth.

Frente view of the Stelpro pulsair RWF0502W wall fan heater, showing the fan grille and lower air outlet.

Diagram showing the dimensions of the Stelpro pulsair RWF0502W wall fan heater: 17 1/8 inches (435 mm) height, 8 11/16 inches (220 mm) width, and 3 3/16 inches (80 mm) depth.
Instalación
Lista de verificación previa a la instalación:
- Asegúrese de que la energía esté desconectada en el disyuntor principal.
- Verifique que el volumen de suministrotage matches the heater's rating (240V).
- Confirm you have a compatible wall thermostat (sold separately).
- Gather necessary tools: screwdriver, wire strippers, drill, level, measuring tape.
Opciones de montaje:
The RWF0502W heater can be either surface-mounted directly to the wall or recessed into the wall for a flush finish. Ensure adequate clearance from floors, ceilings, and adjacent walls as per local codes and manufacturer recommendations.

The Stelpro pulsair RWF0502W wall fan heater installed in a modern entryway, positioned below a plant and mirror.

The Stelpro pulsair RWF0502W wall fan heater installed on a blue wall in an entryway, with coats and shoes nearby.
Conexión eléctrica:
This heater requires a 240V hardwired connection. Follow the wiring diagram provided and ensure all connections are secure and properly insulated. Connect the heater to a dedicated circuit protected by the appropriate circuit breaker.

Diagram illustrating the 240V hardwired connection for the Stelpro pulsair RWF0502W wall fan heater, showing wires connecting within a junction box.
- Turn off power at the main electrical panel.
- Remove the front grille of the heater to access the wiring compartment.
- Connect the supply wires to the heater's terminals according to the wiring diagram. Ensure proper grounding.
- Secure all connections with wire nuts and ensure no bare wires are exposed.
- Reattach the front grille.
- Install the external wall thermostat according to its manufacturer's instructions.
Operación
The Stelpro pulsair RWF0502W heater is controlled by an external wall thermostat (not included). Once installed and wired correctly, follow these steps:
- Encendido: Restore power to the heater circuit at the main electrical panel.
- Configuración del termostato: Adjust the external thermostat to your desired temperature. The heater will activate when the room temperature falls below the set point.
- Operación inicial: During the first few minutes of operation, the heater may emit a slight odor due to the burning off of manufacturing residues. This is normal and will dissipate quickly.
- Rango de temperatura: The heater is designed to operate within a temperature range of 5°C (41°F) to 30°C (86°F).
For optimal performance, avoid placing furniture or other obstructions directly in front of the heater's air outlets.
Mantenimiento
Regular maintenance ensures efficient and safe operation of your Stelpro pulsair heater. Always disconnect power at the main circuit breaker before performing any maintenance.
- Limpieza:
- Limpie el exterior del calentador con un paño suave.amp Paño. No utilice limpiadores abrasivos ni disolventes.
- Aspire periódicamente las rejillas de entrada y salida de aire para eliminar la acumulación de polvo y pelusa.
- Inspección: Annually inspect the heater for any signs of damage, loose connections, or unusual wear. If any issues are found, contact a qualified electrician for repair.
- Sin lubricación: The motor is permanently lubricated and requires no additional oiling.
Solución de problemas
If your Stelpro pulsair heater is not operating correctly, consult the following table before contacting customer support.
| Problema | Posible causa | Solución |
|---|---|---|
| El calentador no enciende. | No llega energía a la unidad. Termostato ajustado demasiado bajo. Se disparó el disyuntor. | Check main electrical panel. Aumente el ajuste del termostato. Restablecer el disyuntor. |
| El calentador produce calor insuficiente. | El tamaño de la habitación es demasiado grande para el calentador. Airflow obstructed. Thermostat calibration issue. | Ensure heater is appropriately sized for the room. Clear obstructions from grilles. Consult thermostat manual or a qualified electrician. |
| Ruido inusual durante el funcionamiento. | Componentes sueltos. Debris in fan. | Disconnect power and inspect for loose parts. Disconnect power and carefully remove any debris. If noise persists, contact support. |
| El calentador se enciende y se apaga con demasiada frecuencia. | Thermostat location or setting. Protección contra sobrecalentamiento activada. | Relocate thermostat away from drafts or direct heat sources. Adjust thermostat differential. Ensure grilles are clear and heater is not covered. Allow unit to cool. |
Presupuesto
| Característica | Detalle |
|---|---|
| Marca | Stelpro |
| Número de modelo | RWF0502W |
| Tipo de montaje | Wall Mount (Surface or Recessed) |
| Tipo de habitación | Dormitorio, oficina en casa, sala de estar |
| Volumentage | 240 voltios |
| Ampanhelo | 2.08 Amps |
| Método de calentamiento | Convection, Forced Air |
| Configuración de temperatura mínima | 5 grados Celsius (41 °F) |
| Ajuste de temperatura máxima | 30 grados Celsius (86 °F) |
| Peso del artículo | 7 libras |
| Dimensiones del paquete | 17.72 x 9.13 x 3.58 pulgadas |
| Código Postal | 626296002285 |
Garantía
Stelpro products are manufactured to high standards and are covered by a limited warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Stelpro webSitio. Conserve su comprobante de compra para reclamaciones de garantía.
Atención al cliente
For technical assistance, replacement parts, or further inquiries, please contact Stelpro customer service. Contact information can typically be found on the product packaging, the official Stelpro website, or by referring to the documentation included with your purchase.
Note: Always provide your product model number (RWF0502W) when contacting support.





