1. Introducción
This manual provides essential information for the safe and efficient use of your Goodman HKSC15XB Electric Heat Kit. This kit is designed to provide supplemental or primary heating for compatible Goodman air handlers. Please read this manual thoroughly before installation or operation and retain it for future reference.
2. Información de seguridad
ADVERTENCIA: La instalación, el ajuste, la alteración, el servicio o el mantenimiento inadecuados pueden provocar daños materiales, lesiones personales o la muerte. La instalación y el servicio deben ser realizados por un instalador o una agencia de servicio calificados.
- Always disconnect power to the air handler and heat kit before performing any service or maintenance.
- Asegúrese de que todas las conexiones eléctricas cumplan con los códigos eléctricos locales y nacionales.
- Esta unidad contiene alto volumentage. Do not attempt to service without proper training and safety equipment.
- Keep combustible materials away from the heat kit and air handler.
3. Producto terminadoview
The Goodman HKSC15XB is a 14.4 kW electric heat kit designed for integration with Goodman air handlers. It operates on a 240V, 1-phase electrical supply and includes a circuit breaker for electrical protection. This kit provides reliable electric heating to complement or serve as the primary heat source for your HVAC system.

Figura 3.1: Interno view of an air handler, illustrating the typical location for an electric heat kit installation. The heat kit integrates with the internal wiring and airflow path of the air handler.
4. Instalación
Installation of the HKSC15XB Electric Heat Kit must be performed by a qualified HVAC technician. This involves electrical wiring, proper mounting within the air handler, and ensuring compatibility with the existing system. Refer to the specific installation instructions provided with the air handler and the heat kit packaging for detailed steps.
4.1 Comprobaciones previas a la instalación
- Verify that the air handler is compatible with the HKSC15XB heat kit.
- Ensure the electrical supply matches the kit's requirements (240V, 1 Phase).
- Confirm adequate clearance for installation and maintenance.
4.2 Conexiones eléctricas
All electrical wiring must be performed by a licensed electrician in accordance with all applicable local and national electrical codes. The heat kit includes a circuit breaker for protection, which must be properly integrated into the electrical circuit.
5. Instrucciones de funcionamiento
The Goodman HKSC15XB Electric Heat Kit operates in conjunction with your air handler and thermostat. Once properly installed and wired, the heat kit will activate automatically when the thermostat calls for heat, providing supplemental or primary heating as needed by the system's control logic.
5.1 Arranque inicial
- Ensure all access panels on the air handler are securely closed.
- Restore power to the air handler and heat kit at the main electrical panel.
- Set your thermostat to heating mode and adjust the temperature setting above the current room temperature to initiate a call for heat.
- Observe the system for proper operation and airflow.
6. Mantenimiento
Regular maintenance ensures the longevity and efficient operation of your electric heat kit. It is recommended to have your HVAC system, including the heat kit, inspected annually by a qualified technician.
- Reemplazo del filtro: Ensure the air filter in your air handler is replaced or cleaned regularly according to the air handler's manual. A dirty filter can restrict airflow and reduce heating efficiency.
- Autorización: Keep the area around the air handler free from obstructions to ensure proper airflow and prevent overheating.
- Conexiones eléctricas: During annual service, a technician should inspect all electrical connections for tightness and signs of wear.
7. Solución de problemas
If you experience issues with your Goodman HKSC15XB Electric Heat Kit, consider the following basic checks before contacting a service technician:
- Sin calor: Check if the circuit breaker for the heat kit (located on the kit itself or in your main electrical panel) has tripped. Reset if necessary. Ensure the thermostat is set correctly and calling for heat.
- Calor reducido: Check the air filter in your air handler. A clogged filter can significantly reduce heating performance.
- Ruidos u olores inusuales: Immediately turn off power to the unit and contact a qualified HVAC technician.
For any issues beyond these basic checks, it is strongly recommended to contact a qualified HVAC service technician for diagnosis and repair.
8. Especificaciones
| Característica | Detalle |
|---|---|
| Fabricante | Buen hombre |
| Número de pieza | HKSC15XB |
| Número de modelo del artículo | HKSC15XB |
| Capacidad de calentamiento | 14.4 kW |
| Volumentage | 240 V |
| Fase | 1 fase |
| Incluye | Cortacircuitos |
| Peso del artículo | 0.01 ounces (Note: This is likely a shipping or packaging weight, actual unit weight may vary.) |
9. Garantía y soporte
Goodman offers enhanced warranty coverage for registered units. To ensure you receive the full benefits of your warranty, register your new Goodman unit. The warranty typically includes:
- Garantía limitada de reemplazo de unidad de 10 años: For eligible units.
- Garantía limitada de por vida del compresor: For eligible units.
- Garantía limitada de piezas de 10 años: Provides replacement part(s) for any part found to be defective due to workmanship or materials under normal use and maintenance.
For detailed warranty terms and conditions, and to register your product, please visit the official Goodman website or contact Goodman customer support. Always provide your model number (HKSC15XB) and serial number when seeking support.

Figura 9.1: Goodman's commitment to comfort and efficiency, highlighting key features of their heating products.