1. Introducción
This manual provides instructions for the safe and effective use of the Extech MM750W Datalogging True RMS Multimeter. The MM750W is a robust, full-featured multimeter designed for professional use, offering 14 functions including non-contact AC voltage detection and Type K temperature measurements. Its CAT IV safety rating ensures protection in industrial environments. A key feature is its wireless datalogging capability via Bluetooth, allowing real-time data transmission to smart devices using the ExView W-Series app.

Figura 1: Frente view of the Extech MM750W Datalogging True RMS Multimeter, showing the display, function dial, and input jacks.
2. Información de seguridad
WARNING: Read and understand all safety information and operating instructions before using this meter. Failure to do so may result in serious injury or death.
- Respete siempre los códigos de seguridad locales y nacionales.
- No utilice el medidor si parece dañado o si los cables de prueba están dañados.
- Asegúrese de que el interruptor de función esté en la posición correcta para la medición que se está realizando.
- Observe all terminal ratings and never exceed the maximum input limits.
- Tenga cuidado al trabajar con vol.tages superior a 30 V CA RMS, 42 V pico o 60 V CC, ya que representan un peligro de descarga eléctrica.
- Utilice equipo de protección personal (EPP) adecuado, como gafas de seguridad y guantes aislantes.
- The MM750W is rated for CAT IV 600V and CAT III 1000V. Understand the implications of these categories for safe measurement.
3. Características principales
- Wireless Datalogging: Records and transmits over 15,000 readings to iOS and Android devices via Bluetooth Datalogging Module (DAT12) for remote viewing using the free ExView W-Series app.
- 14 Measurement Functions: Includes AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode Test, Continuity, Non-Contact AC Voltage (NCV), and Type K Temperature.
- Verdadero valor eficaz: Provides accurate AC measurements for non-sinusoidal waveforms.
- AC µA Function: Ideal for HVAC flame rod current measurements.
- Captura de datos: Allows snapshots of the measurement area with a connected smartphone or tablet camera to document date/time stamps and measurement data.
- Clasificación de seguridad CAT IV: Provides enhanced protection in industrial environments.
4. ¿Qué hay en la caja?
Verifique que todos los artículos estén presentes y sin daños al desembalarlos:
- Extech MM750W Multimeter
- Cables de prueba (uno rojo, uno negro)
- Type K Bead Wire Temperature Probe
- Bluetooth Datalogging Module (DAT12)
- 9V Battery (installed or separate)
- Estuche blando para transporte

Figure 2: The Extech MM750W Multimeter shown with its complete set of accessories, including test leads, a Type K temperature probe, the DAT12 Bluetooth module, and a soft carrying case.
5. Configuración
5.1. Instalación de la batería
- Asegúrese de que el medidor esté apagado.
- Localice el compartimiento de la batería en la parte posterior del medidor.
- Utilice un destornillador para quitar el tornillo que fija la tapa de la batería.
- Retire con cuidado la tapa de la batería.
- Connect a 9V battery to the battery clips, observing correct polarity.
- Coloque la batería en el compartimiento y vuelva a colocar la tapa, asegurándola con el tornillo.
5.2. Conexión del cable de prueba
Always connect the test leads correctly for the desired measurement function.
- Para la mayoría de los volúmenestage, resistance, continuity, and diode measurements, insert the red test lead into the VΩµA input jack and the black test lead into the COM input jack.
- For current measurements up to 600mA, insert the red test lead into the VΩµA input jack and the black test lead into the COM input jack.
- For current measurements up to 10A, insert the red test lead into the 10A input jack and the black test lead into the COM input jack.

Figura 3: Posterior view of the Extech MM750W Multimeter, showing the integrated test lead holders and the battery compartment cover. The test leads are shown connected and stored.
5.3. Bluetooth Datalogging Module (DAT12)
The DAT12 module enables wireless communication with smart devices.
- Insert the DAT12 module into the dedicated port on the top of the multimeter.
- Download the free ExView W-Series app from your device's app store (iOS or Android).
- Habilite Bluetooth en su dispositivo inteligente.
- abre el exView W-Series app and follow the on-screen instructions to pair with the MM750W.
6. Operación
6.1. Medidas básicas
Turn the rotary switch to the desired function. The display will show the measurement value.
- Volumentage (V~, V-): Seleccione el volumen de CA o CCtage. Conecte los cables de prueba en paralelo con el circuito.
- Current (A~, A-): Select AC or DC current. Connect test leads in series with the circuit. Ensure correct input jack (µA/mA or 10A).
- Resistencia (Ω): Turn off power to the circuit. Connect test leads across the component.
- continuidad ()))): Turn off power. Connect test leads across the circuit. A tone indicates continuity.
- Prueba de diodo (→|): Turn off power. Connect test leads across the diode.

Figure 4: An electrician safely measuring voltage within an electrical panel using the Extech MM750W Multimeter. The meter's display is visible, showing a reading.
6.2. Funciones avanzadas
- Vol. CA sin contactotage (VNC): Position the top of the meter near an AC voltage source. The NCV indicator will illuminate, and an audible tone will sound if AC voltagSe detecta e.
- Type K Temperature (Temp): Insert the Type K bead wire probe into the VΩµA and COM jacks (observing polarity). Select the temperature function.
- MÁXIMO MINIMO: Press the MAX/MIN button to record the maximum and minimum readings during a measurement session.
- Modo relativo (REL): Presione el botón REL para almacenar la lectura actual como referencia y mostrar las mediciones posteriores como una desviación de esta referencia.
- Frequency/Duty Cycle (Hz/%): Select the appropriate function to measure frequency or duty cycle of an AC signal.

Figure 5: A technician using the Extech MM750W Multimeter with its Type K temperature probe to measure the temperature of a furnace flue, demonstrating the meter's temperature measurement capability.
6.3. Datalogging and Bluetooth Connectivity
El exView W-Series app enhances the functionality of your MM750W.
- Ensure the DAT12 module is connected and the meter is paired with your smart device via the ExView W-Series app.
- Dentro de la aplicación, puede view real-time readings, initiate datalogging sessions, and configure logging intervals.
- The app allows you to generate reports, analyze collected data, and add notes or photos (taken with your smart device camera) to specific readings for comprehensive documentation.
- Your smart device can also serve as a second display for convenient viewing or sharing of measurements from a safe distance.
7. Mantenimiento
7.1. Limpieza
Limpie la caja del medidor con publicidad.amp Paño y detergente suave. No utilice abrasivos ni disolventes. Asegúrese de que el medidor esté completamente seco antes de usarlo.
7.2. Reemplazo de la batería
When the battery symbol appears on the display, replace the 9V battery as described in Section 5.1. Prompt battery replacement ensures accurate readings and proper meter function.
8. Solución de problemas
| Problema | Posible causa | Solución |
|---|---|---|
| El medidor no se enciende. | Batería muerta o instalada incorrectamente. | Replace or correctly install the 9V battery. |
| Lecturas inexactas. | Incorrect function selected; damaged test leads; low battery. | Verify function switch position; inspect/replace test leads; replace battery. |
| Problemas de conexión Bluetooth. | DAT12 module not properly inserted; Bluetooth disabled on smart device; app not open. | Ensure DAT12 is fully inserted; enable Bluetooth; open ExView W-Series app and retry pairing. |
| Se muestra "OL". | Overload, measurement exceeds meter's range. | Ensure measurement is within the meter's specified range for the selected function. |
9. Especificaciones
| Parámetro | Valor |
|---|---|
| Número de modelo | MM750W |
| Marca | Extec |
| Dimensiones del producto | 2.2 x 7.7 x 3.7 pulgadas |
| Peso del artículo | 16 ounces (1 Pound) |
| Fuente de poder | Funciona con pilas (9 V) |
| Clasificación de seguridad | CAT IV 600 V, CAT III 1000 V |
| Capacidad de registro de datos | 15,000 lecturas |
| Conectividad | Bluetooth (via DAT12 module) |
| Verdadero valor eficaz (RMS) | Sí |
| Vol. CA sin contactotage (VCN) | Sí |
| Medición de temperatura | Tipo K |
10. Garantía y soporte
Extech Instruments provides a warranty for this product against defects in materials and workmanship. Specific warranty terms and duration may vary by region and purchase date. Please refer to the warranty card included with your product or visit the official Extech websitio para obtener información detallada sobre la garantía.
For technical support, service, or replacement parts, please contact Extech Customer Service. Contact information can typically be found on the Extech websitio o en la documentación que acompaña a su producto.