This manual provides detailed instructions for the setup, operation, and maintenance of your AMIR Wireless Refrigerator Thermometer. This device is designed to monitor temperatures in various environments, including refrigerators, freezers, and other indoor spaces, using two wireless sensors. Please read this manual thoroughly before using the product to ensure proper function and longevity.

Información importante de seguridad

Contenido del paquete

Por favor revise el paquete para asegurarse de que todos los artículos estén presentes:

Producto terminadoview

The AMIR Wireless Refrigerator Thermometer consists of a main display unit and two wireless sensors. The main unit displays temperatures from both sensors and its own ambient temperature. It features a large LCD screen with backlight, MAX/MIN record, and an audible alarm function.

Características de la unidad de visualización principal:

AMIR Wireless Refrigerator Thermometer Main Unit and Sensors with Dimensions

Imagen: Main display unit and two wireless sensors with key features and dimensions. The main unit measures 3.7 inches wide by 3 inches high. Each sensor measures 2.1 inches wide by 2.9 inches high. The main unit is powered by 3x AAA batteries, and each sensor by 2x AAA batteries (batteries not included).

Guía de configuración

1. Instalación de la batería

For the Main Display Unit:

  1. Abra la tapa del compartimiento de la batería en la parte posterior de la unidad principal.
  2. Inserte 3 pilas AAA (no incluidas) de acuerdo con las marcas de polaridad (+/-).
  3. Cierre la tapa del compartimento de la batería.

For the Wireless Sensors:

  1. Open the battery compartment cover on the back of each sensor.
  2. Insert 2 AAA batteries (not included) into each sensor according to the polarity markings (+/-).
  3. Close the battery compartment cover. The sensor's LED indicator will flash once, indicating it is transmitting data.

Nota: Use fresh alkaline batteries for optimal performance, especially in low temperatures. Rechargeable batteries are not recommended.

2. Emparejamiento de sensores

The main unit should automatically connect to the sensors once batteries are installed. If a sensor does not connect, or if you need to re-establish connection:

  1. Ensure both the main unit and the sensor are powered on and within range.
  2. On the main unit, press the "CH/+" button to select the desired channel (1 or 2) for the sensor you wish to reconnect.
  3. Press and hold the "CH/+" button for approximately 3 seconds. The main unit will attempt to reconnect to the selected sensor. The signal icon for that channel will flash until a connection is established.

Video: This video demonstrates the basic functions of the Brifit Digital Fridge Thermometer, including indoor/outdoor dual-channel temperature display, backlight activation, switching between Fahrenheit and Celsius, and reconnecting sensors by pressing and holding the CH/+ button. It also shows how to set MAX/MIN alarms and switch between 24H and ALL TIME records.

3. Colocación de sensores

Place the wireless sensors in the desired monitoring locations, such as inside a refrigerator, freezer, or other indoor areas. The sensors are designed to withstand cold temperatures.

AMIR Wireless Refrigerator Thermometer Sensors in Refrigerator and Freezer

Imagen: Two wireless sensors placed inside a refrigerator and a freezer compartment, demonstrating their intended use for monitoring different locations. The main unit displays readings from both sensors. The maximum transmission distance is approximately 328ft/100m in open air.

AMIR Wireless Refrigerator Thermometer Installation Options

Imagen: Various installation options for the main display unit and sensors. The main unit can be placed on a tabletop using its built-in stand or wall-mounted using the hang hole. Sensors also have hang holes for wall mounting or can be placed on shelves. The image shows the battery compartments and stand on the back of the main unit and a sensor.

Instrucciones de funcionamiento

1. Encendido y apagado

The main unit and sensors power on automatically once batteries are installed. There is no manual power on/off button for the sensors. To turn off the main unit, remove its batteries.

2. Selección de la unidad de temperatura (°C/°F)

To switch between Celsius (°C) and Fahrenheit (°F), locate the °C/°F switch inside the battery compartment of the main unit. Slide the switch to your preferred unit.

3. Función de retroiluminación

Press any button on the main unit to activate the backlight for approximately 10 seconds, improving readability in low-light conditions.

AMIR Wireless Refrigerator Thermometer with Backlight On

Imagen: The main display unit with its backlight activated, showing clear temperature readings in a dimly lit room. The large LCD screen is designed for easy reading.

4. Setting Temperature Alarms (MAX/MIN)

The thermometer allows you to set upper (MAX) and lower (MIN) temperature limits for each channel. An audible alarm will sound if the temperature goes outside these set limits.

  1. Press and hold the "ALARM" button for 3 seconds. The MAX alarm value will flash.
  2. Use the "CH/+" or "CLEAR/-" buttons to adjust the MAX temperature limit.
  3. Press the "ALARM" button again to confirm the MAX setting and proceed to the MIN alarm setting. The MIN alarm value will flash.
  4. Use the "CH/+" or "CLEAR/-" buttons to adjust the MIN temperature limit.
  5. Press the "ALARM" button once more to confirm the MIN setting and exit alarm setting mode. The display will return to normal operation.
AMIR Wireless Refrigerator Thermometer Alarm Function

Imagen: The main display unit showing the alarm function, with indicators for MAX and MIN temperature thresholds. An alarm bell icon signifies that the alarm feature is active, alerting users when temperature readings exceed or fall below set limits.

5. Viewing Registros MAX/MIN

The main unit records the maximum and minimum temperatures detected by each sensor and its own ambient sensor.

6. Clearing MAX/MIN Records and Switching 24H/ALL TIME

To clear the MAX/MIN records or switch between 24-hour and all-time records:

Mantenimiento

Limpieza:

Reemplazo de batería:

When the low battery indicator appears on the display, replace the batteries in the respective unit (main unit or sensor) as soon as possible to ensure continuous and accurate monitoring. Follow the battery installation steps in the Setup Guide.

Solución de problemas

ProblemaPosible causaSolución
No temperature reading on a channel.Sensor not paired or out of range; dead batteries in sensor.Check sensor batteries and replace if necessary. Re-pair the sensor by pressing and holding the "CH/+" button on the main unit for 3 seconds. Move sensor closer to the main unit.
Lecturas de temperatura inexactas.Sensor placed too close to heat sources or vents; low batteries.Relocate the sensor to a more representative area. Replace batteries.
La pantalla está tenue o en blanco.Low or dead batteries in the main unit.Reemplace las baterías en la unidad principal.
La alarma suena inesperadamente.Temperature exceeded set MAX/MIN limits.Check the current temperature and the set alarm limits. Adjust limits if needed.

Presupuesto

CaracterísticaDetalle
MarcaEmir
Número de modelo4868e9ff-1090-40b4-8a6a-025a98227e17
Tipo de pantallaLCD digital con retroiluminación
Tecnología de conectividadInalámbrico
Fuente de alimentación (unidad principal)Funciona con pilas (3 pilas AAA, no incluidas)
Fuente de alimentación (sensores)Battery Powered (2x AAA per sensor, not included)
Característica especialAudible Alarm, MAX/MIN Record
Uso en interiores y exterioresInterior
Tiempo de respuesta10 segundos
Peso del artículo7 onzas
MaterialPlástico

Garantía y soporte

AMIR provides the following support for this product:

Documentos relacionados - 4868e9ff-1090-40b4-8a6a-025a98227e17

Preview Manual del usuario del termómetro para refrigerador AMIR
Manual de usuario del termómetro para refrigeradores AMIR, detallando sus características, funcionamiento y especificaciones para el monitoreo de temperatura en refrigeradores, congeladores y cocinas.
Preview Manual de usuario del reloj despertador digital AMIR: características y funcionamiento
Guía completa del usuario del reloj despertador digital AMIR, que detalla sus funciones como la pantalla LED, el indicador de temperatura, el brillo ajustable, el control por voz e instrucciones para configurar la hora, la fecha, la alarma y el modo nocturno. Incluye opciones de alimentación y pasos de funcionamiento.
Preview Manual de usuario del despertador con radio FM
Manual de usuario completo del despertador con radio FM, que detalla la configuración, funciones como la alarma, el funcionamiento de la radio FM, la configuración de la pantalla, el modo fin de semana, la carga USB, el cambio de batería y las especificaciones. Incluye solución de problemas y preguntas frecuentes.
Preview Caja fuerte portátil AMIR: instrucciones de apertura y solución de problemas
Guía detallada para abrir su caja fuerte portátil AMIR, incluyendo soluciones para problemas relacionados con la presión. Aprenda a acceder a su almacenamiento seguro con instrucciones paso a paso.
Preview Manual del usuario de la estación meteorológica inalámbrica para el hogar Ambient Weather WS-1090
Comprehensive user manual for the Ambient Weather WS-1090 wireless home weather station. Provides detailed instructions for installation, setup, operation, PC software usage, troubleshooting, and specifications. Covers temperature, humidity, wind, rain, barometric pressure, and more.