The ThermoPro TP30 Infrared Thermometer Gun is a versatile and accurate tool designed for non-contact surface temperature measurement. Utilizing advanced thermopile sensor technology, it provides rapid readings across a wide temperature range, making it ideal for various applications including cooking, HVAC diagnostics, automotive maintenance, and home repairs. This manual provides detailed instructions to help you get the most out of your device.
Características principales
- Highly Accurate: Accurate to ±1.5% with adjustable emissivity (0.1–1.0) for precise measurements on different surfaces.
- Ultra-Fast Response: Provides temperature readings in less than 500 milliseconds.
- Wide Temperature Range: Measures temperatures from -58°F to 1022°F (-50°C to 550°C).
- User-Friendly Display: Backlit LCD screen displays MAX/MIN/AVG temperatures and automatically shuts off after 90 seconds of inactivity.
- Laser Targeting: Features a 12:1 distance-to-spot ratio with a laser pointer for accurate targeting.
- Commonly-Found Batteries: Powered by 2 AAA batteries (included) with a low battery indicator.
Configuración
Instalación de la batería
Your ThermoPro TP30 requires two AAA batteries for operation. Follow these steps to install them:
- Localice la tapa del compartimiento de la batería en el mango del termómetro.
- Deslice o desenganche suavemente la tapa para abrir el compartimento.
- Inserte dos pilas AAA, asegurándose de la polaridad correcta (+ y -) como se indica dentro del compartimento.
- Cierre bien la tapa del compartimento de la batería.

Encendido inicial
Once batteries are installed, simply pull the trigger to power on the device. The backlit LCD screen will illuminate, and the thermometer will be ready for use.
Instrucciones de funcionamiento
Tomando una medida
Para medir la temperatura de la superficie de un objeto:
- Point the infrared lens towards the target surface.
- Pull and hold the trigger. The laser pointer will activate, indicating the measurement area.
- The temperature reading will instantly appear on the LCD screen.
- Suelte el gatillo para mantener la última temperatura medida en la pantalla.

Understanding the Display Modes
The TP30 offers various display modes to provide comprehensive temperature data:
- MÁX: Muestra la temperatura máxima registrada durante un escaneo continuo.
- MÍNIMO: Muestra la temperatura mínima registrada durante un escaneo continuo.
- AVG: Muestra la temperatura promedio registrada durante un escaneo continuo.
Press the "MODE" button to cycle through these display options.

Temperature Units (°C/°F)
To switch between Celsius (°C) and Fahrenheit (°F), press the "°C/°F" button located on the device.
Emisividad ajustable
Emissivity is the ability of a material to emit energy by radiation. Different materials have different emissivities. For the most accurate readings, adjust the emissivity setting (EMISS.) on your TP30 to match the surface you are measuring. The emissivity can be adjusted from 0.1 to 1.0.

Funciones adicionales
- Iluminar desde el fondo: Press the light bulb button to turn the display backlight on or off for improved visibility in different lighting conditions.
- Apagado automático: El termómetro se apagará automáticamente después de 90 segundos de inactividad para conservar la vida útil de la batería.
- Indicador de batería baja: Un icono en la pantalla indicará cuando las baterías están bajas y necesitan ser reemplazadas.

Vídeo oficial del producto
Mantenimiento
Limpieza
To clean your ThermoPro TP30, simply wipe it with a clean, damp cloth. Do not immerse the device in water or use abrasive cleaners.
Almacenamiento
Store the thermometer in a dry place away from extreme temperatures and direct sunlight. Remove batteries if the device will not be used for an extended period to prevent leakage.
Solución de problemas
If you encounter issues with your ThermoPro TP30, refer to the following common solutions:
| Problema | Posible causa | Solución |
|---|---|---|
| Sin pantalla o pantalla tenue | Baterías bajas o agotadas; Instalación incorrecta de la batería. | Replace batteries with new AAA batteries; Ensure correct polarity. |
| Lecturas inexactas | Incorrect emissivity setting; Distance to target too far or too close; Lens is dirty. | Adjust emissivity to match material; Maintain optimal distance (12:1 D:S ratio); Clean the infrared lens. |
| El láser no funciona | La función láser está desactivada. | Presione el botón láser para activar el puntero láser. |
| El dispositivo no enciende | Batteries are not installed or are dead. | Install or replace batteries. |
| NOTE: Not for Human Body Temperature | This device is designed for surface temperature measurement only. | Do not use for medical purposes or to measure human body temperature. |
Presupuesto
| Especificación | Detalle |
|---|---|
| Rango de temperatura | -58 ° F ~ 1022 ° F (-50 ° C ~ 550 ° C) |
| Exactitud | ±1.5% |
| Relación distancia-punto (D:S) | 12:1 |
| Tiempo de respuesta | < 500 ms |
| Emisividad | Ajustable 0.1 - 1.0 |
| Fuente de poder | 2 pilas AAA (incluidas) |
| Apagado automático | 90 segundos de inactividad |
| Tipo de pantalla | LCD digital retroiluminado |
| Material | Plástico |
| Peso del artículo | 4.5 onzas |
| Nombre del modelo | TP30 |
Garantía y soporte
ThermoPro products are designed for reliability and performance. For warranty information, technical support, or any questions regarding your TP30 Infrared Thermometer Gun, please visit the official ThermoPro webSitio web o contacte directamente con el servicio de atención al cliente. Conserve el recibo de compra para reclamaciones de garantía.
Official ThermoPro Websitio: www.thermopro.com