Introducción
This manual provides detailed instructions for the safe installation, operation, and maintenance of your VOLT 150W Clamp Conectar bajo volumentage Transformer with Digital Timer. Please read this manual thoroughly before installation and retain it for future reference.

Imagen: Frente view of the VOLT 150W Clamp Conectar bajo volumentage Transformer in its closed, stainless steel housing.
Información importante de seguridad
- Desconecte la energía antes de instalar o dar servicio a este equipo.
- Do not exceed the maximum primary current of 5 Amps.
- This unit is equipped with a thermal protector. If a circuit overloads or short circuits, the thermal protector will automatically shut off power. Reset by pushing the circuit breaker.
- Adecuado para uso interior o exterior.
- Siga siempre los códigos y regulaciones eléctricas locales.
- Asegure una conexión a tierra adecuada.
Características del producto
- Clamp-Type Terminal Blocks: Tool-free wire insertion and clamping for secure connections. Supports up to 10-gauge wire.
- High Performance Toroidal Core: Ensures reliable, efficient, cooler, and quieter operation.
- Designed for LED Systems: Features 12V for short runs and 15V for longer runs or multiple fixtures.
- Professional Grade Construction: ETL listed, stainless steel enclosure with lockable hinged lid, and spacious wire compartment.
- Astronomic Digital Timer: Automatically determines dusk/dawn times based on geographical location, eliminating manual adjustments. Features a large, easy-to-read LCD display.

Image: The transformer with its front cover open, revealing the internal wiring, terminal blocks, timer receptacle, and photocell plug.
Configuración e instalación
- Montaje: Securely mount the transformer to a wall or suitable vertical surface using appropriate hardware. Ensure it is in a location that allows for proper ventilation and access.
- Conexión de energía: Plug the transformer into a standard 120V AC outlet.
- Cableado de luces de paisaje:
- Strip approximately 1/2 inch of insulation from the ends of your landscape lighting wires.
- Abre la clamp-type terminal blocks by pressing down on the lever.
- Insert the stripped wire fully into the desired common (COM1 or COM2) and voltage tap (12V or 15V) terminals.
- Release the lever to secure the wire. Ensure all connections are tight.
- Timer/Photocell Setup:
- The unit includes a timer receptacle and a photocell plug. The digital timer (included) can be plugged into the timer receptacle.
- If using an external photocell (sold separately), remove the jumper from the photocell plug and insert the photocell.

Imagen: Un detalle view de la clamp-type terminal blocks, showing wires inserted into the COM, 12V, and 15V terminals.
Vídeo: Este vídeo ofrece una visión generalview of the VOLT Clamp-Connect Low Voltage Transformers, demonstrating key features and the easy connection process using clamp-terminales tipo.
Operating Instructions: Digital Timer
The included Astronomic Digital Timer simplifies the control of your landscape lighting.

Image: The Astronomic Digital Timer, showing its LCD display and various control buttons for setup and operation.
Configuración del temporizador
- Configuración inicial: Follow the timer's specific instructions to set the current time, date, and your geographical location. This allows the timer to accurately calculate local dusk and dawn times.
- Programming On/Off Cycles: Program the desired ON and OFF times for your lighting. The astronomic feature will adjust these times daily based on the changing dusk/dawn schedule.
- Anulación manual: Most digital timers include a manual override function to temporarily turn lights on or off outside of programmed schedules.
Refer to the separate instruction sheet provided with the digital timer for detailed programming steps.
Mantenimiento
- Inspección regular: Periodically inspect the transformer and wiring for any signs of damage, corrosion, or loose connections.
- Limpieza: Keep the transformer enclosure clean and free of debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
- Ventilación: Ensure that the transformer's ventilation openings are not obstructed to prevent overheating.
- Corta circuitos: If the circuit breaker trips, disconnect some lights or check for short circuits before resetting.
Solución de problemas
| Problema | Posible causa | Solución |
|---|---|---|
| Las luces no encienden | No llega energía al transformador | Verifique la toma de corriente y el disyuntor. |
| Las luces no encienden | Conexión de cableado defectuosa | Inspect all wire connections at the terminal blocks. Ensure wires are fully inserted and clamppublicado por |
| Las luces no encienden | Digital timer not programmed correctly | Review timer instructions and reprogram. |
| Las luces parpadean o se atenúan | Volumentage drop due to long wire runs or too many fixtures | Use the 15V tap for longer runs or reduce the number of fixtures. Ensure appropriate wire gauge is used. |
| Viajes de disyuntores | Sobrecarga o cortocircuito | Disconnect some lights. Inspect wiring for shorts. Reset the circuit breaker. |
Presupuesto
- Modelo: 150 W
- Vol de entradatage: 120 V CA
- Vol de salidatage: 12 V CA, 15 V CA
- Wat máximotage: 150 W
- Dimensiones (alto x ancho x profundidad): 13.19" x 6.00" x 5.41"
- Peso: 15.01 libras
- Material del recinto: Acero inoxidable
- Certificaciones: Listado en ETL
- Fuente de energía: Eléctrico con cable
- Tipo de montaje: Montaje en pared

Image: Technical drawing illustrating the height, width, and depth dimensions of the transformer.
Garantía y soporte
This VOLT transformer is backed by a lifetime warranty. For technical assistance, troubleshooting, or warranty claims, please contact VOLT Lighting customer support.
Visit the official VOLT Lighting webSitio para obtener información de contacto y recursos adicionales.