Maxxima MEW-USB480C

Maxxima USB Wall Outlet Receptacle Instruction Manual

Model: MEW-USB480C

Introducción

This manual provides instructions for the installation, operation, and maintenance of the Maxxima USB Wall Outlet Receptacle (Model MEW-USB480C). This device integrates two standard AC outlets with one USB-A and one USB-C charging port, offering a versatile power solution for various electronic devices.

Información de seguridad

WARNING: RISK OF ELECTRIC SHOCK OR FIRE. INSTALLATION REQUIRES KNOWLEDGE OF ELECTRICAL WIRING SYSTEMS. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN.

  • Apague la energía en el disyuntor o la caja de fusibles antes de la instalación.
  • Use only with copper wire. Do not use with aluminum wire.
  • Asegúrese de que todas las conexiones de cables estén seguras y adecuadamente aisladas.
  • Este dispositivo está diseñado únicamente para uso en interiores.
  • Do not exceed the electrical ratings of the device.
  • Tamper-resistant shutters are designed to prevent insertion of foreign objects into the receptacle openings.

Contenido del paquete

  • Maxxima USB Wall Outlet Receptacle (MEW-USB480C)
  • Placa de pared
  • Tornillos terminales

Presupuesto

CaracterísticaEspecificación
Número de modeloMEW-USB480C
Clasificación del receptáculo15 Amp, 125 VCA
Clasificación USBTotal 4.8 Amp, 5 VDC (1 USB-A, 1 USB-C)
Dispositivos compatiblesSmartphones, Tablets, MP3 Players, Gaming Devices
MaterialCobre
ColorBlanco
Dimensiones (paquete)5.28 x 2.99 x 1.97 pulgadas
Peso (Paquete)5.5 onzas
CertificacionesListado por UL
CaracterísticasTamper-Resistant (TR) Shutters, Smart Identification Chip

Configuración e instalación

Antes de comenzar: Ensure power is OFF at the circuit breaker. If you are unsure about electrical wiring, consult a qualified electrician.

  1. Apagar la energía: Locate the circuit breaker controlling the outlet where you intend to install the receptacle. Switch the breaker to the OFF position. Verify power is off using a voltage probador.
  2. Retire el receptáculo viejo: Unscrew and carefully pull the existing receptacle from the wall box. Disconnect the wires from the old receptacle, noting which wire was connected to which terminal (Hot, Neutral, Ground).
  3. Prepare los cables: Si es necesario, retire aproximadamente 1,27 cm del aislamiento de los extremos de los cables. Asegúrese de que los cables estén rectos y sin muescas.
  4. Examine the Receptacle: Familiarize yourself with the physical components of the new receptacle.
    Frente view of Maxxima USB Wall Outlet Receptacle without wall plate, showing mounting tabs.
    Frente view without wall plate, showing mounting tabs.
    Lado view of Maxxima USB Wall Outlet Receptacle, showing depth and wiring terminals.
    Lado view, illustrating depth and wiring access.
  5. Conectar cables:
    • Conectar el CALIENTE (black or red) wire to the brass-colored screw terminals.
    • Conectar el NEUTRAL (white) wire to the silver-colored screw terminals.
    • Conectar el SUELO (bare copper or green) wire to the green screw terminal.

    Ensure all connections are tight and secure. For back-wiring, insert the stripped wire into the appropriate hole and tighten the screw.

    Atrás view of Maxxima USB Wall Outlet Receptacle, showing wiring diagram and ground screw.

    This image shows the back of the Maxxima USB Wall Outlet Receptacle, detailing the wiring instructions (HOT, WHITE, GR) and the ground screw for proper electrical connection.

  6. Receptáculo de montaje: Vuelva a colocar con cuidado el receptáculo cableado en la caja de pared. Fíjelo con los tornillos de montaje incluidos.
  7. Instale la placa de pared: Attach the included wall plate over the receptacle and secure it with the provided screws.
  8. Restaurar energía: Vuelva a colocar el disyuntor en la posición ON (encendido).
  9. Funcionalidad de prueba: Test both the standard AC outlets and the USB charging ports to ensure proper operation.Frente view of Maxxima USB Wall Outlet Receptacle with wall plate installed.

    This image shows the Maxxima USB Wall Outlet Receptacle fully installed with its white wall plate, featuring two standard AC outlets, one USB-A port, and one USB-C port.

Instrucciones de funcionamiento

The Maxxima USB Wall Outlet Receptacle provides both standard AC power and USB charging capabilities.

  • Standard AC Outlets: Insert any standard 2-prong or 3-prong electrical plug into the AC outlets. These outlets are tamper-resistant for safety.
  • Puertos de carga USB: The receptacle features one USB-A port and one USB-C port. Connect your compatible device's charging cable to the appropriate USB port.
  • Carga inteligente: The built-in smart identification chip recognizes the charging requirements of your connected devices (e.g., smartphones, tablets, MP3 players) and optimizes the charging speed up to a combined total of 4.8 Amps.
  • Protección contra sobrecarga: If the total power demand from connected USB devices exceeds 4.8 Amps, the smart detection system will reduce the charging rate to protect your devices and the receptacle.
Maxxima USB Wall Outlet Receptacle installed in a wall, charging a smartphone via USB-A port.
Charging a smartphone via the USB-A port.
Close-up of Maxxima USB Wall Outlet Receptacle, charging a smartphone via USB-C port.
Charging a smartphone via the USB-C port.

Mantenimiento

The Maxxima USB Wall Outlet Receptacle requires minimal maintenance.

  • Limpieza: Disconnect power at the circuit breaker before cleaning. Wipe the surface with a soft, damp Paño. No utilice limpiadores abrasivos ni disolventes.
  • Inspección: Periodically inspect the receptacle for any signs of damage, loose connections, or discoloration. If any issues are observed, turn off power and consult a qualified electrician.

Solución de problemas

ProblemaPosible causaSolución
No power from AC outlets.Se disparó el disyuntor; conexión de cableado suelta.Check and reset the circuit breaker. Verify wiring connections are secure (turn off power first).
Los puertos USB no cargan.Device incompatibility; faulty cable; total current draw exceeds 4.8A; loose connection.Try a different USB cable. Test with another device. Ensure total current draw is within 4.8A. Some high-power devices (e.g., certain iPads, MacBooks, or specific Android phones) may require higher power delivery than this unit provides via USB-C.
La carga es lenta.Multiple devices connected; device requires higher charging rate; cable quality.Disconnect other USB devices. Use a high-quality charging cable. Note that the total output is 4.8A shared between both USB ports.
Wall plate does not sit flush.Receptacle not fully seated in wall box; wires not properly arranged.Ensure wires are neatly folded into the wall box. Gently push the receptacle fully into the box before tightening mounting screws.

Garantía y soporte

This Maxxima USB Wall Outlet Receptacle (Model MEW-USB480C) is backed by a Garantía de 1 años a partir de la fecha de compra.

For technical support, warranty claims, or further assistance, please contact Maxxima customer service. Refer to the Maxxima webSitio o embalaje del producto para obtener información de contacto actualizada.

Fabricante: maxxima

Documentos relacionados - MEW-USB480C

Preview Guía de instalación del tomacorriente de pared Maxxima MEW-USB482C TR con puertos USB-A y USB-C
Instrucciones de instalación y seguridad para el Maxxima MEW-USB482C TampTomacorriente de pared TR resistente a impactos, con puertos de carga USB-A y USB-C. Este receptáculo de carga de alta velocidad incluye dos tomacorrientes estándar y puertos USB-C/A integrados, diseñados para dispositivos inteligentes. Incluye diagramas de cableado e información sobre la garantía.
Preview Maxxima MEW-USB482C TR Wall Outlet with USB-A and USB-C Ports - Installation Guide
Installation guide and product information for the Maxxima MEW-USB482C Tamper Resistant TR Wall Outlet featuring USB-A and USB-C charging ports. Includes safety warnings, FCC compliance, warranty details, and step-by-step installation instructions.
Preview Guía de instalación del interruptor unipolar Maxxima MEW-RS100W con toma de corriente
Instrucciones de instalación e información de garantía del interruptor unipolar Maxxima MEW-RS100W con toma de corriente. Aprenda a instalar y cablear el dispositivo de forma segura.
Preview Instrucciones de instalación del regulador deslizante de 3 vías Maxxima serie MEW-DM600
Guía de instalación completa para atenuadores deslizantes unipolares y de 3 vías Maxxima MEW-DM600, MEW-DM600A, MEW-DM600B, MEW-DM600V, que cubre cableado, montaje y funcionamiento.
Preview Guía de instalación del interruptor unipolar Maxxima con toma de corriente
Guía de instalación completa para el interruptor unipolar con toma de corriente Maxxima (modelo MEW-RS100W), que incluye advertencias de seguridad, especificaciones y diagramas de cableado.
Preview Guía de instalación del interruptor unipolar Maxxima MEW-RST100W con toma de corriente
Installation guide for the Maxxima MEW-RST100W Single Pole Switch with Power Outlet, including specifications, warnings, cautions, and warranty information.