POOLEX PC-SLP090N

Manual del usuario de la bomba de calor POOLEX Silverline Inverter 90

Model: PC-SLP090N

Introducción

This manual provides essential information for the safe and efficient operation of your POOLEX Silverline Inverter 90 Heat Pump. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper use and to prevent damage to the unit or injury to yourself.

Información de seguridad

Always adhere to local electrical codes and regulations. Installation must be performed by a qualified professional. Disconnect power before performing any maintenance or service. Do not operate the unit if any part is damaged. Keep children and pets away from the unit during operation. Ensure proper ventilation around the heat pump.

Contenido del paquete

Verifique que todos los componentes enumerados a continuación estén presentes en su paquete:

Configuración

  1. Colocación: Position the heat pump on a stable, level surface, ensuring adequate clearance for air circulation around the unit. Use the provided anti-vibration mounts to minimize noise and vibration.
  2. Conexión de fontanería: Connect the heat pump to your pool's filtration system using the supplied PVC connectors (Ø 50 mm, 1 ½). Ensure all connections are watertight. The unit is suitable for pools up to 50 m³.
  3. Conexión eléctrica: Connect the heat pump to a dedicated electrical circuit as per local regulations. This should be done by a certified electrician.
  4. Drenaje condensado: Attach the condensate drain hose to the designated outlet on the unit and route it to a suitable drainage point.
  5. Panel de control remoto: The LED control panel can be moved up to 10 meters away from the unit using the extension cable for convenient access.
  6. Encendido inicial: Once all connections are secure, power on the unit.

Instrucciones de funcionamiento

The POOLEX Silverline Inverter 90 Heat Pump is designed for efficient and quiet operation, featuring a Mitsubishi multi-frequency compressor and variable fan.

  1. Operación del panel de control: Use the integrated LED control panel to set the desired water temperature and operating mode. Refer to the detailed operating manual for specific button functions and menu navigation.
  2. Wi-Fi Connectivity (Smart Life App): The heat pump features Wi-Fi technology for control via a dedicated smartphone application.
    • Download the official POOLEX or compatible Smart Life application from your device's app store.
    • Follow the in-app instructions to pair your heat pump with your smartphone.
    • Once connected, you can monitor and adjust settings remotely.
    • Note: Some users have reported issues with Smart Life functionality. Ensure your Wi-Fi network is stable and the app is updated to the latest version. Consult the troubleshooting section or manufacturer support if issues persist.
  3. Rendimiento de calefacción: The Twisted Tech Titan spiral exchanger ensures rapid temperature increase. The unit boasts a high COP (Coefficient of Performance) of 16 at 26°C/26°C, indicating high energy efficiency.

Mantenimiento

Regular maintenance ensures the longevity and optimal performance of your heat pump.

Solución de problemas

Esta sección aborda problemas comunes que podrías encontrar.

ProblemaPosible causaSolución
Unit not heating pool water.Insufficient water flow; low ambient temperature; incorrect settings.Check pool pump operation and filter cleanliness. Ensure ambient temperature is within operating range. Verify temperature settings on control panel/app.
La unidad no se enciende.No power supply; tripped circuit breaker; internal fault.Check power connection and circuit breaker. If problem persists, contact qualified technician.
Smart Life App connectivity issues.Unstable Wi-Fi network; incorrect pairing procedure; app version outdated.Ensure strong Wi-Fi signal. Re-attempt pairing process as per manual. Update the Smart Life app. If issues continue, contact POOLEX support.
Ruido inusual de la unidad.Debris in fan; loose components; anti-vibration mounts not installed correctly.Inspect fan for obstructions (power off first). Check for loose screws. Ensure anti-vibration mounts are properly seated.

Presupuesto

CaracterísticaDetalle
Número de modeloPC-SLP090N
Dimensiones del producto82.4 x 33.4 x 65.6 cm
Peso25 kilogramos
Tipo de materialTitan (for heat exchanger)
Tipo de unidadAccionado hidráulicamente
Fabricanteestrella de la piscina
Volumen adecuado de la piscinaHasta 50 m³
COP (Coeficiente de Rendimiento)16 (at 26°C/26°C)

Garantía y soporte

POOLEX is committed to 100% customer satisfaction. If you have any questions regarding the product, installation, operation, or require technical assistance, please visit the official POOLEX websitio o póngase en contacto con su servicio de atención al cliente.

For further support, you can visit the POOLEX store on Amazon: POOLEX Store

Documentos relacionados - PC-SLP090N

Preview Poolex Silverline Top Heat Pump Installation and User Manual
Discover the Poolex Silverline Top heat pumps, offering up to 80% energy savings for swimming pools with R32 refrigerant. This manual provides detailed installation, operation, and maintenance guidance.
Preview Poolex Silverline Top: Installation and User Manual
Comprehensive guide for the installation, operation, and maintenance of the Poolex Silverline Top heat pump. Learn about its features, technical specifications, and safety precautions for optimal performance.
Preview Poolex Silverline FI Heat Pump Installation and User Manual
Comprehensive guide for the Poolex Silverline FI heat pump, covering installation, operation, maintenance, and troubleshooting. Learn how to set up and use your heat pump for optimal performance.
Preview Bomba de calor Poolex Silverline Top: Manual de instalación y uso
Manual completo de instalación y uso de la serie de bombas de calor Silverline Top de Poolex. Incluye instrucciones de seguridad, especificaciones técnicas, guías de instalación, funcionamiento, mantenimiento y solución de problemas.
Preview Poolex Silverline Top Wärmepumpe: Installations- und Bedienungsanleitung
Umfassende Installations- und Bedienungsanleitung für die Poolex Silverline Top Wärmepumpen-Serie (Modelos 6 a 20 kW). Enthält wichtige Sicherheitshinweise, technische Daten, Installationsschritte, Bedienungsanleitungen und Wartungsinformationen.
Preview Bomba de calor Poolex: Manual de seguridad, instalación y usuario
Hoja de datos de seguridad completa, guía de instalación y manual de usuario para bombas de calor para piscinas Poolex, que cubre el funcionamiento seguro, el mantenimiento y la resolución de problemas.