BFT P125002 SB-BAT

Manual del usuario del kit de batería de respaldo de 24 V CC SB-BAT para abridor de portones BFT P125002

Model: P125002 SB-BAT

1. Producto terminadoview

The BFT SB-BAT (P125002) is a 24v DC battery backup system designed to ensure continuous operation of your gate opener even during power outages. This kit provides a reliable power source, activating automatically when the main power supply is interrupted and recharging when power is restored.

It is compatible with various BFT gate opener models, including the Deimos BT series, VIRGO - LINX, EOS-SCE, HYDRA N, DEIMOS BT-QSC D-NETTUNO S, SB BAT/SB CARBAT (DEIMOS BT-SB 300), BT BAT 2 (URANO BT ARES 1000 & ARES 1500) NETTUNO B, VENERE D, ARGO, LIBRA C MA - LIBRA C LX.

BFT P125002 SB-BAT Battery Backup Kit components

Figure 1: Contents of the BFT P125002 SB-BAT Battery Backup Kit, including batteries, wiring, and mounting hardware.

2. Configuración e instalación

Installation of the BFT SB-BAT kit is designed to be straightforward. It integrates with your existing BFT gate opener system.

2.1. Precauciones de seguridad

2.2. Pasos de instalación

  1. Desempaquetar componentes: Carefully remove all items from the packaging. Verify all components are present as shown in Figure 1.
  2. Mount the Battery Housing: Securely mount the battery housing unit near your gate opener's control board, ensuring it is protected from environmental elements.
  3. Conecte las baterías: Insert the two 12V 1.2Ah batteries into the housing. Connect them according to the wiring diagram provided with the kit (typically in series to achieve 24V DC).
  4. Connect to Gate Opener: Connect the battery backup system's wiring to the designated battery input terminals on your BFT gate opener's control board. Consult your gate opener's manual for precise terminal locations.
  5. Cableado seguro: Ensure all wiring is neatly routed and secured to prevent accidental disconnections or damage.
  6. Restaurar energía: Once all connections are secure and verified, restore main power to the gate opener. The smart charger board will begin charging the batteries.
Close-up of BFT P125002 SB-BAT components including batteries and wiring

Figura 2: Una vista más cercana view of the battery backup kit components, highlighting the batteries and connection wires.

3. Operación

The BFT SB-BAT battery backup system operates automatically to provide uninterrupted gate functionality.

4. Mantenimiento

El mantenimiento regular garantiza la longevidad y confiabilidad de su sistema de respaldo de batería.

5. Solución de problemas

This section addresses common issues you might encounter with your BFT SB-BAT battery backup kit.

ProblemaPosible causaSolución
Gate does not operate during power outage.
  • Las baterías no están cargadas.
  • Conexiones de cableado sueltas o incorrectas.
  • Batteries are at end of life.
  • Fusible fundido.
  • Ensure main power is connected and the charger board is functioning. Allow 12-14 hours for full charge.
  • Check all wiring connections between the battery kit and the gate opener.
  • Test batteries; replace if necessary.
  • Check and replace the 20A fuse if blown.
Batteries do not seem to be charging.
  • Main power supply issue.
  • Faulty charger board.
  • Conexión incorrecta de la batería.
  • Verify main power to the gate opener.
  • Contact BFT support for charger board diagnosis.
  • Recheck battery wiring according to the manual.

6. Especificaciones

Key technical specifications for the BFT SB-BAT (P125002) battery backup system:

7. Garantía y soporte

For warranty information or technical support, please refer to the documentation included with your purchase or contact BFT customer service directly. Keep your proof of purchase for warranty claims.

You can find more information about BFT products on their official websitio o a través de distribuidores autorizados.

Documentos relacionados - P125002 SB-BAT

Preview Sistema de automatización de puertas electromecánicas BFT DEIMOS BT UL/CSA
Descubra el BFT DEIMOS BT UL/CSA, un sistema de automatización electromecánica para puertas correderas de cremallera. Con tecnología inteligente, funcionamiento seguro a 24 V e instalación sencilla, este sistema mejora la seguridad y la comodidad de la puerta. Explore sus especificaciones técnicas y los accesorios disponibles para aplicaciones residenciales y comerciales.
Preview Manual de instalación de la automatización de puertas batientes BFT VIRGO
Guía completa de instalación y uso del sistema de automatización de puertas batientes BFT VIRGO, que cubre seguridad, especificaciones técnicas, procedimientos de instalación, programación y mantenimiento.
Preview Guía de instalación del sistema de control por radio BFT CLONIX1-2 y MITTO 2-4 de 433 MHz
Guía de instalación completa para el receptor BFT CLONIX1-2 y los transmisores de control por radio MITTO 2-4 de 433 MHz, que cubre programación, clonación, seguridad y especificaciones técnicas para la automatización de puertas y portones.
Preview Manual de instalación de BFT THALIA: Quadro Comandi per Automazione Cancelli
Questa guida dettagLiata illustra l'installazione e la configurazione del quadro comandi BFT THALIA, progettato per l'automazione di cancelli e porte. Incluya técnicas específicas, esquemas de colaboración e instrucciones operativas para garantizar un funcionamiento seguro y eficiente.
Preview Guía de referencia rápida del kit BFT Phobos BT UL
Guía de referencia rápida para el sistema de apertura de puerta automático BFT Phobos BT Kit UL, que cubre la instalación, el cableado, la programación y la resolución de problemas.
Preview Instrucciones de codificación del control remoto BFT MITTO 2B | Controles remotos retro
Guía paso a paso para codificar controles remotos BFT MITTO 2B para abridores de portones, que abarca los métodos existentes para controles remotos y pantallas LCD de receptores. Incluye consejos para la resolución de problemas.