1. Introducción
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your BERNSTEIN R18W White Steel Bathroom Towel Radiator. Please read these instructions carefully before installation and retain them for future reference. This radiator is designed for use with standard central heating systems and can also be adapted for electric operation (electric heating element not included).
2. Instrucciones de seguridad
- Installation must be performed by a qualified professional in accordance with local building and wiring regulations.
- Ensure the radiator is securely mounted to a suitable wall structure capable of supporting its weight when filled with water.
- No cubra el radiador con materiales inflamables.
- Keep children and pets away from the radiator when it is hot to prevent burns.
- Before any maintenance or cleaning, ensure the radiator is cool and, if connected to an electrical supply, disconnected from power.
- No utilice limpiadores abrasivos ni disolventes en la superficie del radiador.
- The radiator is designed for heating towels and warming the bathroom space. Do not use it for purposes other than its intended function.
3. Contenido del paquete
Compruebe que todos los componentes estén presentes y sin daños antes de continuar con la instalación.
- BERNSTEIN R18W Towel Radiator (1200x500mm)
- Soportes y fijaciones para montaje en pared
- Straight towel rail accessory
- Tapón de ventilación de aire
- Tapón de cierre
Nota: A connection kit (valves, electric heating element) is No incluido and must be purchased separately if required.
4. Producto terminadoview
The BERNSTEIN R18W is a modern white steel towel radiator designed for bathrooms. It features a rectangular shape with horizontal tubes and vertical D-profiles, providing both efficient heating and a stylish appearance.

Image 1: BERNSTEIN R18W towel radiator in a bathroom setting.

Imagen 2: Frente view of the BERNSTEIN R18W radiator, highlighting its 1200x500mm dimensions.
The radiator is finished in White RAL9016 and includes a straight towel rail for added functionality.

Image 3: The included straight towel rail accessory and an example of a towel on a radiator.
5. Instalación
5.1 Comprobaciones previas a la instalación
- Verify that the wall where the radiator will be mounted is structurally sound and can support the weight of the radiator when filled with water.
- Ensure adequate space around the radiator for proper heat distribution and access for maintenance.
- Confirm that the plumbing connections (lateral or central, G1/2" connectors) are correctly positioned.
5.2 Montaje en pared
- Refer to the technical drawing for precise dimensions and mounting point locations.
- Mark the drilling points on the wall using the provided mounting brackets as a template.
- Drill holes and insert appropriate wall plugs (ensure they are suitable for your wall type).
- Fije los soportes de montaje a la pared.
- Carefully lift the radiator and position it onto the secured brackets.
- Tighten any retaining screws on the brackets to firmly hold the radiator in place.

Image 4: Technical drawing with detailed dimensions and connection options.
5.3 Conexiones de fontanería
The radiator offers both lateral and central connection options with G1/2" connectors. Connect the radiator to your central heating system using appropriate valves (not included). Ensure all connections are sealed properly to prevent leaks.

Imagen 5: Primer plano view of the top connection point.

Imagen 6: Primer plano view of the bottom connection points.
5.4 Filling and Bleeding
- Once plumbing connections are secure, slowly fill the central heating system.
- Open the air vent plug at the top of the radiator using a radiator key to release trapped air.
- Close the air vent plug once water starts to emerge steadily.
- Compruebe todas las conexiones para detectar fugas.
6. Operación
6.1 Funcionamiento de la calefacción central
The BERNSTEIN R18W radiator operates as part of your existing central heating system. Adjust the heat output using the radiator valves (not included) or your central heating thermostat.
6.2 Funcionamiento eléctrico (opcional)
This radiator can be converted for electric-only operation by installing a suitable electric heating element (not included) and filling it with a heat transfer fluid. This modification must be carried out by a qualified electrician and plumber, adhering to all electrical safety standards.
7. Mantenimiento
7.1 Limpieza
Limpie el radiador periódicamente con un paño suave.amp cloth. For stubborn marks, a mild soap solution can be used. Rinse thoroughly and dry immediately. Avoid abrasive cleaners, scouring pads, or chemical solvents as these can damage the finish.
7.2 Purga del radiador
If the top of the radiator feels cold while the bottom is hot, it indicates trapped air. Bleed the radiator as described in Section 5.4 to ensure efficient operation.
7.3 Controles anuales
Periodically check all connections for any signs of leaks or corrosion. Ensure mounting brackets remain secure.
8. Solución de problemas
| Problema | Posible causa | Solución |
|---|---|---|
| Radiator not heating up fully (cold at top) | Aire atrapado | Bleed the radiator using the air vent plug. |
| El radiador no calienta en absoluto | Valves closed, central heating system off, or system fault | Check radiator valves are open. Ensure central heating system is operational. Consult a heating engineer if system fault is suspected. |
| Fugas de agua en las conexiones | Conexiones sueltas o sellos defectuosos | Tighten connections (do not overtighten). Replace seals if necessary. Consult a plumber. |
9. Especificaciones
| Marca | ÁMBAR |
| Modelo | R18W |
| Dimensiones (Alto x Ancho) | 1200 mm x 500 mm |
| Material | Acero |
| Finalizar | Blanco RAL9016 |
| Tubos horizontales | Ø 22 mm, straight |
| Profesional verticalfiles | D-profiles: 30 x 40 mm |
| Opciones de conexión | Lateral or central, G1/2" connectors |
| Método de instalación | Montaje en pared |
| Certificaciones | Certificado CE |
| Accesorios incluidos | Straight towel rail, wall mounting kit, air vent plug, blanking plug |
| Kit de conexión | No incluido |
10. Garantía y soporte
For warranty information and customer support, please refer to the documentation provided at the point of purchase or visit the official BERNSTEIN webSitio. Conserve su comprobante de compra para cualquier reclamación de garantía.