1. Introducción
This manual provides detailed instructions for the safe and efficient operation of your Lacidoll 2.1Gal 8L Top Fill Large Humidifier. Please read this manual thoroughly before use and retain it for future reference. This humidifier is designed to increase humidity levels in rooms up to 500 sq.ft., offering features such as top-fill convenience, automatic humidity control, and an essential oil tray.
2. Instrucciones de seguridad importantes
- Coloque siempre el humidificador sobre una superficie firme, plana y nivelada.
- No coloque el humidificador directamente sobre una alfombra o toalla.
- Desenchufe el humidificador del tomacorriente antes de llenarlo, limpiarlo o realizar cualquier mantenimiento.
- Never add water directly into the mist outlet or base chamber. Only add water through the designated top-fill opening. Adding water to the mist outlet can damage the device.
- Do not add essential oils directly into the water tank. Use only the designated essential oil tray.
- Mantenga el humidificador fuera del alcance de los niños y las mascotas.
- Ensure the water tank is securely placed on the base before operation to prevent leaks.
- Do not operate the humidifier if any part is damaged or malfunctioning. Contact customer support for assistance.
3. Contenido del paquete
Carefully unpack all items and ensure all components are present. If any items are missing or damaged, please contact customer support.
- Lacidoll Humidifier Unit
- Cable de alimentación
- Mando a distancia
- Mist Outlet Extensions (various configurations)
- Cleaning Sponge/Brush
- Manual de usuario
4. Configuración y funcionamiento inicial
4.1 Asamblea
- Place the humidifier base on a flat, stable surface.
- Retire la cubierta superior del humidificador.
- Attach the desired mist outlet extension(s) to the top of the humidifier. You can choose between a direct 360-degree dispenser or use extension tubes for higher mist output.
- Connect the power cord to the humidifier's power inlet at the back.
4.2 Llenado del depósito de agua
- Asegúrese de que el humidificador esté desenchufado de la toma de corriente.
- Open the top-fill cover.
- Pour clean, cool tap water directly into the water tank through the top opening. Do not exceed the 'MAX' fill line.
- Close the top-fill cover securely.

Figure 1: Illustration of the top-fill method for adding water to the humidifier.
5. Instrucciones de funcionamiento
5.1 Encendido y apagado
- Plug the power cord into a suitable electrical outlet. The display will briefly illuminate.
- Press the Power button on the control panel or remote control to turn the humidifier on or off.
5.2 Ajustes de niebla
- Press the Mist button to cycle through three mist output levels: Low, Medium, and High.

Figure 2: Visual representation of the three available mist output levels.
5.3 Auto Mode and Humidistat
- The built-in humidistat allows the humidifier to automatically adjust mist output to maintain a desired humidity level.
- Press the Humidity button to set your target humidity level (e.g., 50%). The humidifier will operate until this level is reached, then pause and resume as needed.
- The humidifier features an automatic shut-off function when the water tank is empty or if the unit is tilted/falls over.

Figure 3: Smart Humidity Mode with adjustable settings.
5.4 Temporizador y modo de suspensión
- Press the Timer button to set an operating duration from 1 to 12 hours. The humidifier will automatically turn off after the set time.
- Press the Sleep button to enter sleep mode. The display lights will turn off, and the humidifier will operate at a low, quiet setting.
5.5 UV Light Function
- The humidifier includes a built-in UV light to help sanitize the mist. Press the UV button to activate or deactivate this feature.

Figure 4: UV light feature for mist sanitization.
5.6 control remoto
- All functions can be controlled using the included remote control. Ensure the remote has a working battery.

Figura 5: Control remoto para una operación conveniente.
5.7 Demostración en vídeo
Video 1: A brief demonstration of the humidifier's quiet operation and night light feature in a bedroom setting.
6. Mantenimiento y limpieza
Regular cleaning is essential to prevent mineral buildup and maintain optimal performance.
- Desenchufe siempre el humidificador antes de limpiarlo.
- Remove the top cover and mist outlet extensions.
- The wide water tank opening allows you to fit your hand inside for thorough cleaning. Use the provided cleaning sponge/brush and a mild detergent if necessary.
- Enjuague bien el tanque con agua limpia.
- Limpie el exterior del humidificador con un paño suave yamp paño.
- Ensure all parts are completely dry before reassembling and operating the humidifier.

Figura 6: Fácil acceso para limpiar el tanque de agua.
7. Bandeja para aceites esenciales
To use essential oils with your humidifier:
- Locate the essential oil tray on the side of the humidifier.
- Slide out the tray.
- Place a tissue paper into the tiny essential oil tray (this helps prolong machine lifetime).
- Add a few drops of your preferred essential oil onto the tissue paper.
- Slide the tray back into the humidifier.
Warning: Do NOT add essential oils directly into the water tank, base chamber, or mist tube. This can damage the humidifier and void the warranty.

Figure 7: Proper use of the essential oil tray.
8. Especificaciones
| Característica | Especificación |
|---|---|
| Marca | Lacidol |
| Nombre del modelo | LCDJSQ-011 |
| Capacidad | 2.1 galones (8 litros) |
| Salida de humedad | 300 ml/h |
| Área de cobertura | Hasta 500 pies cuadrados |
| Modo de operación | Ultrasónico |
| Nivel de ruido | < 35dB (Whisper-Quiet) |
| Quétage | 28 vatios |
| Dimensiones del producto | 10.24" de profundidad x 10.43" de ancho x 29.53" de alto |
| Peso del artículo | 5.5 libras |
| Características especiales | Humidistat, Quiet, Remote Control, UV-light, Auto Shut-Off, Essential Oil Tray, 12-hour Timer, 3 Mist Settings |
9. Solución de problemas
Si encuentra algún problema con su humidificador, consulte los siguientes problemas y soluciones comunes:
- Sin salida de niebla: Ensure the water tank is filled and correctly seated. Check if the power cord is securely plugged in. If the unit has been running for a while, check for mineral buildup and clean the unit.
- Fugas de agua: Verify that the water tank is properly aligned and sealed on the base. Ensure the humidifier is placed on a flat, level surface. Avoid overfilling the water tank beyond the MAX line.
- Ruido inusual: A slight trickling sound of water is normal. If the noise is excessive, ensure the unit is on a stable surface and not vibrating against other objects. Check for any obstructions in the fan or mist outlet.
- Polvo blanco: This is typically caused by hard water. Consider using distilled or demineralized water to reduce white dust accumulation. Regular cleaning also helps.
- Humidifier Not Reaching Desired Humidity: Ensure the room size is within the humidifier's coverage area (up to 500 sq.ft.). Close windows and doors to prevent humidity from escaping. Increase the mist output setting.
10. Garantía y soporte
The Lacidoll 2.1Gal 8L Top Fill Large Humidifier comes with a 12-month warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For warranty claims, technical assistance, or any questions regarding your product, please contact Lacidoll customer support. Refer to the contact information provided in your product packaging or on the official Lacidoll websitio.