This manual provides instructions for the installation, operation, and maintenance of the Vimar 02970 thermostat. This device is designed for controlling heating and cooling systems with ON/OFF functionality, featuring a control knob, relay output, and an LED backlight with brightness adjustment. It is compatible with Vimar Eikon, Arké, or Plana frames.

2. Información de seguridad

3. Producto terminadoview

The Vimar 02970 thermostat offers intuitive control over your climate system. Key features include:

Vimar 02970 Thermostat Front View

Figura 1: Frente view of the Vimar 02970 thermostat, showing the central display, control knob, and surrounding icons for temperature units, light, and mode selection.

4. Configuración e instalación

4.1 Desembalaje

Carefully remove the thermostat and any included components from the packaging. Verify that all parts are present.

4.2 Montaje

The Vimar 02970 thermostat is designed to be integrated into Eikon, Arké, or Plana frames. Ensure the chosen frame is compatible.

Vimar 02970 Thermostat installed in a wall frame

Figure 2: The Vimar 02970 thermostat integrated into a wall frame, demonstrating its flush-mount appearance.

4.3 Cableado

Before wiring, ensure the main power supply to the circuit is disconnected.

  1. Identify the power supply wires (Live, Neutral) and the heating/cooling system control wires (Common, Normally Open, Normally Closed).

  2. Connect the Live (L) and Neutral (N) wires to the corresponding terminals on the thermostat. The thermostat operates on 100-240V~, 50/60Hz.

  3. Connect the heating/cooling system control wires to the C (Common), NO (Normally Open), and NC (Normally Closed) relay output terminals as required by your system.

  4. Ensure all connections are secure. The terminals are designed for wires up to 6 mm².

Vimar 02970 Thermostat rear view con terminales de cableado

Figura 3: Posterior view of the Vimar 02970 thermostat, showing the screw terminals for electrical connections (L, N, C, NO, NC).

Vimar 02970 Thermostat side view con detalles de cableado

Figura 4: Lado view of the Vimar 02970 thermostat, illustrating the depth and the wiring terminals with specifications (100-240V~, 5(2)A, 1B.U, -T40).

4.4 Encendido inicial

After wiring, restore power at the main circuit breaker. The thermostat display should illuminate.

5. Instrucciones de funcionamiento

5.1 Encendido y apagado

Presione el ícono de encendido () located on the bottom left of the thermostat to turn the device on or off.

5.2 Ajuste de la temperatura

Rotate the central control knob clockwise to increase the set temperature and counter-clockwise to decrease it. The current set temperature will be displayed on the LED screen.

Hand adjusting Vimar 02970 Thermostat control knob

Figure 5: A hand rotating the central control knob of the Vimar 02970 thermostat to adjust the temperature setting.

5.3 Changing Mode (Heating/Cooling)

The thermostat supports both heating and cooling modes. The mode can typically be switched using a dedicated button or a combination of button presses. Refer to the on-screen icons for current mode indication (e.g., snowflake for cooling, sun for heating).

5.4 Ajuste del brillo de la luz de fondo

The LED backlight brightness can be adjusted. Consult the Vimar website for specific instructions on accessing this setting, as it may involve keyboard shortcuts.

5.5 Programming (If Applicable)

The thermostat features "Friendly Programming." For detailed instructions on setting schedules or advanced programming options, refer to the comprehensive tutorials available on the official Vimar websitio.

6. Mantenimiento

7. Solución de problemas

ProblemaPosible causaSolución
Thermostat display is off.No hay suministro de energía.Revise el disyuntor principal. Asegúrese de que las conexiones del cableado sean seguras.
El sistema (calefacción/refrigeración) no responde.Incorrect wiring; thermostat in wrong mode; set temperature not reached.Verify wiring connections. Ensure the thermostat is in the correct mode (heating/cooling). Adjust the set temperature to be above/below the ambient temperature to trigger the system.
La lectura de temperatura parece inexacta.Ubicación del termostato afectada por corrientes de aire o fuentes de calor.Ensure the thermostat is not installed near windows, doors, or direct heat/cold sources.

8. Especificaciones

CaracterísticaDetalle
Número de modelo02970
MarcaVIMAR
Volumentage100-240 V~
Frecuencia50/60 Hz
Salida de relé5(2)A, 1B.U
Temperatura de funcionamiento-T40 (Specific range not provided, consult Vimar documentation)
Peso del artículo70 gramos
Dimensiones del producto4.15 x 4.48 x 4.9 cm (42D x 45W x 49H millimeters)
Tipo de controladorpomo mecanico
Características especialesLighted (LED Backlight)
ConectividadCableado
Marcos compatiblesEikon, Arké, or Plana
Vimar 02970 Thermostat technical dimensions diagram

Figure 6: Technical diagram showing the dimensions of the Vimar 02970 thermostat (41.7mm depth, 44.8mm width, 49mm height).

9. Garantía y soporte

For warranty information, technical support, or additional tutorials, please visit the official Vimar website or contact your local Vimar distributor. The Vimar website provides comprehensive instructions and tutorials for programming and advanced features.