1. Introducción
This manual provides detailed instructions for the installation, operation, and maintenance of the Elitech CP-6000N Current Monitoring Relay. The CP-6000N is designed for comprehensive electrical system protection, offering current monitoring, overload protection, phase monitoring, and temperature control capabilities with RS-485 communication.
2. Información de seguridad
Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in equipment damage, personal injury, or death. Only qualified personnel should perform installation and maintenance.
- Disconnect all power sources before wiring or servicing the device.
- Asegure una conexión a tierra adecuada para evitar descargas eléctricas.
- Verify all connections are secure and correct according to the wiring diagram.
- No opere el dispositivo en entornos que excedan sus condiciones de funcionamiento especificadas.
3. Producto terminadoview
The Elitech CP-6000N is an advanced current monitoring relay offering robust protection features for industrial and commercial applications. It integrates new phase sequence detection, phase loss protection, unbalance, and overload protection. With a three-phase current detection capability up to 200A and RS-485 communication, it allows for real-time remote monitoring.

Figura 1: Frente view of the Elitech CP-6000N Current Monitoring Relay, showing the digital display and control buttons.

Figure 2: Icons representing key features of the CP-6000N, including phase sequence, phase loss, unbalance, overload protection, 220A maximum current, RS-485 communication, and alarm function.
4. Características
- New phase sequence detection and protection design.
- Phase loss protection.
- Unbalance protection.
- Protección de sobrecarga.
- Three-phase current detection, with over-current protection up to 200A.
- Higher measurement accuracy: up to ±2A (0-30A).
- RS-485 communication function for remote monitoring of compressor running status.
- Current measurement range: 2-80A; 30-200A.
5. Especificaciones
| Especificación | Valor |
|---|---|
| Marca | Élitech |
| Modelo | CP-6000N-SP-220V |
| Tipo de montaje | Montaje en carril DIN |
| Iluminar desde el fondo | Sí |
| Tipo de conector | Tornillo |
| Material de contacto | Plata |
| Tipo de contacto | Normalmente cerrado |
| Calificación actual | 200 Amps |
| Modo de operación | Automático |
| Certificaciones | Certificado CE y UL |
| Código Postal | 781454242306 |
6. Configuración e instalación
6.1 Montaje
The Elitech CP-6000N is designed for DIN Rail mounting. Ensure the DIN rail is securely installed in a suitable enclosure, providing adequate ventilation and protection from environmental factors.

Figure 3: Mounting dimensions of the CP-6000N, indicating a width of 2.8 inches and a height of 1.14 inches.
6.2 Diagrama de cableado
Follow the wiring diagram carefully to ensure correct power supply, current sensor connections, and RS-485 communication. Incorrect wiring can lead to malfunction or damage.

Figure 4: Wiring diagram for the CP-6000N, showing terminals for Alarm, Power (W, V, U, N), Current Sensor (COM, A, B, C), and RS-485 (B-, A+).
Descripciones de terminales:
- 1-2: Alarm output contacts.
- 3-6 (W, V, U, N): Three-phase power input.
- 7 (COM): Common terminal for current sensors.
- 8-10 (A, B, C): Current sensor inputs for phases A, B, and C.
- 11-12 (B-, A+): RS-485 communication terminals.
7. Instrucciones de funcionamiento
7.1 Funcionamiento básico
The CP-6000N features a digital display and several buttons for configuration and monitoring.

Figure 5: A hand interacting with the control buttons of the CP-6000N, highlighting ease of use.
- Colocar/View Botón: Press to enter parameter setting mode or view diferentes parámetros.
- Botón Esc: Press to exit the current menu or cancel an operation.
- Flechas arriba/abajo: Use to navigate through menu options or adjust parameter values.
7.2 Current Monitoring
The device continuously monitors the three-phase current. The current measurement range is 2-80A or 30-200A, depending on the specific model variant. The digital display shows the measured current values.
7.3 Comunicación RS-485
The integrated RS-485 communication function allows the CP-6000N to be connected to a network for remote monitoring. This enables real-time tracking of compressor status and other operational data. Refer to the RS-485 communication protocol document for detailed integration instructions.
8. Mantenimiento
The Elitech CP-6000N is designed for reliable operation with minimal maintenance. However, periodic checks are recommended to ensure optimal performance and longevity.
- Inspección visual: Inspeccione periódicamente el dispositivo para detectar cualquier signo de daño físico, conexiones sueltas o sobrecalentamiento.
- Limpieza: Mantenga el dispositivo limpio y libre de polvo y residuos. Utilice un paño suave y seco para limpiarlo. No utilice limpiadores líquidos.
- Comprobaciones de conexión: Periodically verify that all wiring connections are secure.
9. Solución de problemas
If the CP-6000N exhibits unexpected behavior or displays fault codes, refer to the following information.

Figure 6: Table of fault codes and their meanings for the CP-6000N.
| No. | Código de falla | Significado |
|---|---|---|
| 1 | EPS | Error de secuencia de fase |
| 2 | Liga Premier Inglesa | Protección contra pérdida de fase |
| 3 | Fin de vida útil | Protección contra sobrecarga |
| 4 | EUb | Protección contra desequilibrio |
Consejos generales para la solución de problemas:
- Sin energía: Check power supply connections and circuit breakers.
- Lecturas incorrectas: Verify current sensor connections and calibration settings.
- Problemas de comunicación: Check RS-485 wiring, baud rate, and address settings.
10. Garantía y soporte
Elitech products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Elitech websitio.
For technical support, troubleshooting assistance, or service inquiries, please contact Elitech customer service through their official websitio o la información de contacto proporcionada con su compra.