Elitech SVP-7

Elitech SVP-7 7 CFM 2-Stage Smart Vacuum Pump Instruction Manual

Modelo: SVP-7 | Marca: Elitech

1. Información de seguridad

Please read and understand all safety warnings and instructions before operating the Elitech SVP-7 vacuum pump. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.

2. Contenido del paquete

Verifique que todos los artículos estén presentes en el paquete:

Elitech SVP-7 Vacuum Pump and included accessories

Image: Elitech SVP-7 Vacuum Pump and its included accessories, such as vacuum oil and the user manual.

3. Características del producto

The Elitech SVP-7 Smart Vacuum Pump is designed with advanced features for efficient and reliable HVAC/R system evacuation:

Elitech SVP-7 Smart Vacuum Pump features overview

Imagen: Una sobreview of the Elitech SVP-7's smart features, including touchscreen, app control, and leak detection.

4. Configuración

4.1 Initial Inspection and Oil Filling

  1. Unpack the vacuum pump and inspect for any shipping damage.
  2. Asegúrese de que el interruptor de encendido esté en la posición "APAGADO".
  3. Remove the oil fill cap and fill the pump with the provided vacuum oil until the oil level is between the 'MIN' and 'MAX' marks on the sight glass.
  4. Vuelva a colocar la tapa de llenado de aceite de forma segura.

4.2 Connecting the Vacuum Gauge

For precise vacuum measurement, connect a compatible micron gauge to the pump or system:

Video: This video demonstrates the process of connecting a vacuum pump with a micron gauge for accurate readings during HVAC/R system evacuation.

4.3 Encendido

Connect the power cord to a suitable electrical outlet. Press the power switch to turn on the pump. The 4-inch touchscreen will illuminate, displaying the main interface.

Elitech SVP-7 Large Touch Screen Display

Image: The large touchscreen display of the Elitech SVP-7, showing real-time vacuum changes and operational data.

5. Instrucciones de funcionamiento

5.1 Funcionamiento básico

  1. From the main screen, tap 'Measure' to view real-time vacuum data.
  2. Tap 'Run' to start the vacuum pump. The pump will begin evacuating the system.
  3. Monitor the vacuum level and other parameters on the touchscreen.
  4. Tap 'Stop' to halt the pump operation.

5.2 Control de aplicaciones móviles

The Elitech SVP-7 can be controlled and monitored remotely via the Elitech Tools mobile app (iOS/Android):

  1. Download and install the 'Elitech Tools' app from your device's app store.
  2. Ensure Bluetooth is enabled on your mobile device and the vacuum pump.
  3. Open the app, search for the SVP-7, and connect.
  4. From the app, you can remotely start/stop the pump, monitor vacuum levels, and export PDF reports.
Elitech SVP-7 Real-time Monitoring Via APP

Image: A technician monitoring the Elitech SVP-7 via the mobile app on a rooftop HVAC unit.

Video: This video demonstrates the features and usage of the Elitech PGW Wireless Digital Pressure Gauge, including app connectivity and data management.

5.3 Smart Leak Detection System

The integrated leak detection system provides a risk scale (0-100) to identify potential leaks:

Elitech SVP-7 Detect System Leakage Level

Image: The Elitech SVP-7 touchscreen displaying the system leakage level and other operational statuses.

5.4 Real-Time Vacuum Graph

The touchscreen and app display a real-time vacuum graph, allowing visual monitoring of the evacuation process:

Elitech SVP-7 Intelligent and Simple Interface

Image: The Elitech SVP-7's intelligent and simple interface, highlighting the vacuum graph and other smart features.

5.5 Automated Operation

The pump features automated functions for convenience:

Elitech SVP-7 Automatic Switch on and off

Image: The Elitech SVP-7 operating automatically, allowing a technician to monitor progress remotely.

6. Mantenimiento

6.1 Cambio de aceite

Regular oil changes are crucial for optimal pump performance and longevity. Change the vacuum pump oil after every 10-20 hours of operation or if the oil appears cloudy or discolored.

  1. Asegúrese de que la bomba esté apagada y desconectada de la alimentación.
  2. Coloque un recipiente adecuado debajo del tapón de drenaje de aceite.
  3. Retire el tapón de drenaje de aceite y la tapa de llenado de aceite para permitir que el aceite viejo se drene por completo.
  4. Reemplace el tapón de drenaje de aceite.
  5. Refill with new industrial-grade ISO 46 vacuum pump oil until the level is between the 'MIN' and 'MAX' marks on the sight glass.
  6. Vuelva a colocar la tapa de llenado de aceite.

6.2 Limpieza general

Keep the pump clean and free from dust and debris. Wipe down the exterior with a damp paño. No utilice productos químicos ni disolventes agresivos.

6.3 Almacenamiento

When not in use, store the vacuum pump in a dry, clean environment, protected from extreme temperatures and direct sunlight.

7. Solución de problemas

ProblemaPosible causaSolución
La bomba no arrancaSin energía, interruptor defectuoso, problema con el motorCheck power connection, ensure switch is ON. If problem persists, contact support.
Mal rendimiento del vacíoLow oil level, contaminated oil, system leak, clogged intakeCheck/change oil, use leak detection system, inspect connections, clean intake.
La bomba se sobrecalientaInsufficient ventilation, prolonged operation, low oil levelEnsure adequate airflow, allow pump to cool, check oil level. Auto-shutdown will activate at 122°F.
Oil backflowApagado automáticotage during operation, faulty solenoid valveThe solenoid valve is designed to prevent this. If it occurs, check valve function and system integrity.

8. Especificaciones

CaracterísticaDetalle
MarcaÉlitech
ModeloSVP-7
Caudal7 CFM (3 Liters Per Second)
Vacío definitivo15 micrones
Stages2-Stage
Potencia del motor3 / 4 HP
Fuente de poderEléctrico con cable
Peso del artículo38.4 libras
Dimensiones del producto20.47 x 16.93 x 14.96 pulgadas
Mostrar4" Touchscreen
ConectividadBluetooth (Mobile App Control)
Características de seguridadSolenoid Valve, 122°F Auto-Shutdown
Elitech SVP-7 Vacuum Pump Specifications

Image: A detailed graphic outlining the technical specifications of the Elitech SVP-7 vacuum pump.

9. Garantía y soporte

Elitech products are designed for reliability and performance. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included in your package or visit the official Elitech websitio.

For technical support, troubleshooting assistance, or service inquiries, please contact Elitech customer service through the contact information provided in your user manual or on the Elitech website. Our dedicated support team is available to assist you.

You can also find additional resources, FAQs, and product updates on the Elitech websitio: Tienda Elitech

Documentos relacionados - SVP-7

Preview Manual de usuario del detector de corona Elitech WJL-6000S
Manual de usuario del detector de corona Elitech WJL-6000S, que proporciona instrucciones detalladas sobre el funcionamiento, la detección, la resolución de problemas y el mantenimiento para la detección de fugas de refrigerante en varios sistemas.
Preview Manual del usuario del detector de fugas halógeno Elitech HLD-200
This user manual provides comprehensive instructions for operating and maintaining the Elitech HLD-200 Halogen Leak Detector. It covers technical specifications, operation procedures, leak detection methods, troubleshooting, and maintenance tips for effective use in refrigeration and HVAC systems.
Preview Manual de usuario del detector de fugas de refrigerante infrarrojo de la serie Elitech ILD
Manual de usuario completo para los detectores infrarrojos de fugas de refrigerante de la serie Elitech ILD (ILD-100, ILD-200, ILD-300), que abarca especificaciones, funcionamiento, mantenimiento y características. Aprenda a detectar fugas de refrigerante eficazmente con este dispositivo avanzado.
Preview Manual del usuario del detector de fugas infrarrojo Elitech ILD-100/ILD-200/ILD-300
Manual de usuario de los detectores infrarrojos de fugas de refrigerante de la serie ILD de Elitech (ILD-100, ILD-200, ILD-300). Ofrece información detallada sobre el funcionamiento, las especificaciones, las características y el mantenimiento para una detección precisa de fugas de refrigerante.
Preview Manual del usuario del detector de fugas de diodo calentado e infrarrojo Elitech IR-200
Manual de usuario completo del Elitech IR-200, un detector de fugas de doble sensor con tecnología infrarroja y de diodo calefactado. Conozca sus especificaciones, funcionamiento, mantenimiento y funciones para detectar fugas de refrigerante.
Preview Colector digital Elitech MS-100: Manual del usuario y especificaciones
Guía completa del colector digital Elitech MS-100, que abarca sus características, especificaciones técnicas, funcionamiento, instrucciones de seguridad y solución de problemas. Aprenda a usar el dispositivo para mediciones de presión y temperatura, pruebas de fugas, procesos de vacío y registro de datos con la aplicación Elitech Tools.