Fireangel CO-9X10

Manual del usuario de la alarma de monóxido de carbono FireAngel CO-9X10

Su guía para un uso seguro y eficaz

Introducción

The FireAngel CO-9X10 is a certified carbon monoxide (CO) alarm designed to provide continuous monitoring for the presence of carbon monoxide gas. Featuring an advanced electrochemical sensor developed by FireAngel, this device ensures accurate detection of CO at low concentrations, offering maximum safety for your home or workplace. It comes with a built-in lithium battery designed for a 10-year lifespan, providing reliable protection without the need for battery replacement.

This manual provides essential information on the installation, operation, maintenance, and troubleshooting of your CO-9X10 alarm. Please read it thoroughly before installation and keep it for future reference.

FireAngel CO-9X10 Carbon Monoxide Alarm front view

Figura 1: Frente view of the FireAngel CO-9X10 Carbon Monoxide Alarm. This image shows the main body of the alarm with the central test/reset button and the Power, Fault, and Alarm indicator lights.

Información importante de seguridad

Carbon monoxide (CO) is a colorless, odorless, and tasteless gas that can be fatal. This alarm is designed to detect carbon monoxide gas from any source of combustion. It is not designed to detect smoke, fire, or other gases. For optimal safety, ensure proper ventilation and regular maintenance of fuel-burning appliances.

Contenido del paquete

Verifique el contenido del paquete para asegurarse de que todos los artículos estén presentes:

Configuración e instalación

Elección de una ubicación

For optimal protection, install CO alarms in or near every room where fuel-burning appliances are located, and in sleeping areas. Consider placing an alarm on every level of your home. Avoid placing the alarm:

Montaje de la alarma

The CO-9X10 can be wall-mounted or placed on a flat surface. For wall mounting:

  1. Select a suitable location, ideally at eye level or higher, but not directly on the ceiling unless specified by local regulations.
  2. Use the mounting bracket as a template to mark the drill holes on the wall.
  3. Drill two holes and insert the provided wall plugs.
  4. Screw the mounting bracket firmly to the wall.
  5. Attach the CO alarm to the mounting bracket by aligning the alarm with the bracket and twisting it clockwise until it clicks into place.
FireAngel CO-9X10 Carbon Monoxide Alarm with indicators

Figura 2: Frente detallado view of the FireAngel CO-9X10 showing the Power, Fault, and Alarm LED indicators. This view is helpful for understanding the device's status at a glance.

FireAngel CO-9X10 Carbon Monoxide Alarm side view

Figura 3: Lado view of the FireAngel CO-9X10 Carbon Monoxide Alarm, illustrating its compact profile and potential mounting features. This perspective can be useful for understanding how the device sits against a wall or on a surface.

Activación inicial

The CO-9X10 features a sealed-in lithium battery. The alarm will activate automatically when it is correctly attached to its mounting bracket. Upon activation, the green Power LED will flash once every 45 seconds, indicating normal operation.

Instrucciones de funcionamiento

Indicadores LED

Prueba de la alarma

It is crucial to test your CO alarm weekly to ensure it is functioning correctly.

  1. Press and hold the large "TEST/RESET" button on the front of the alarm.
  2. The alarm will sound a loud, distinctive pattern (typically 4 beeps, pause, 4 beeps) and the Red Alarm LED will flash.
  3. Release the button. The alarm should stop sounding, and the Red Alarm LED should stop flashing.
  4. If the alarm does not sound or the LEDs do not respond as described, refer to the Troubleshooting section.

Qué hacer si suena la alarma

If your CO alarm sounds, it indicates the presence of carbon monoxide. Follow these steps immediately:

  1. Evacuar inmediatamente: Move everyone, including pets, to fresh air outdoors or open doors/windows to ventilate the area.
  2. Do not re-enter the premises until the alarm has stopped and the area has been ventilated.
  3. Llame a los servicios de emergencia: Contact your local emergency services (e.g., 999 in the UK) or a qualified gas technician to investigate the source of the CO.
  4. Identify and resolve the source: Do not use fuel-burning appliances until they have been checked by a professional.

Característica de silencio

The alarm may have a silence feature for nuisance alarms (e.g., from temporary high CO levels during appliance startup). Pressing the "TEST/RESET" button during an alarm may silence it for a short period. However, if the CO level remains high, the alarm will reactivate. Only use the silence feature if you are certain it is a nuisance alarm and not a genuine CO threat.

Mantenimiento

Limpieza regular

Clean your CO alarm regularly to prevent dust and debris from affecting its performance. Use a soft, damp cloth to wipe the exterior. Do not use cleaning solvents or sprays directly on the alarm.

Battery Life and End-of-Life Signal

The FireAngel CO-9X10 is equipped with a sealed-in lithium battery designed to last for 10 years. When the alarm reaches the end of its operational life, it will emit a specific end-of-life signal (e.g., two short beeps every 45 seconds, accompanied by the Amber Fault LED flashing). When this occurs, the alarm needs to be replaced immediately.

Solución de problemas

ProblemaPosible causaSolución
Alarm sounds continuously (Red LED flashing)High level of Carbon Monoxide detected.Evacuar inmediatamente. Call emergency services. Do not re-enter until cleared by professionals.
Amber Fault LED flashing / Alarm chirping intermittentlyLow battery or fault detected.The battery is sealed and cannot be replaced. If the alarm is chirping due to low battery or fault, it has reached its end-of-life or is malfunctioning. Reemplace la alarma inmediatamente.
Alarm does not sound when Test button is pressedAlarm malfunction or end-of-life.Ensure the alarm is properly mounted. If it still doesn't respond, the alarm is faulty or has reached its end-of-life. Reemplace la alarma inmediatamente.
Green Power LED not flashingAlarm not activated or malfunction.Ensure the alarm is securely attached to its mounting bracket. If the issue persists, the alarm may be faulty. Reemplace la alarma.

Presupuesto

CaracterísticaDetalle
Número de modeloCO-9X10
Tipo de sensorElectroquímico
Fuente de poderSealed-in Lithium Battery (10-year life)
Volumen de alarmaAudible
Dimensiones del producto11.2 x 3.5 x 7.2 cm
Peso del artículo150 gramos
CertificacionesBSI EN50291-1:2010 and EN50291-2:2010 Certified
Código Postal816317003609

Garantía y soporte

FireAngel products are manufactured to the highest standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official FireAngel website. If you experience any issues with your CO-9X10 alarm or require technical assistance, please contact FireAngel customer support. Do not attempt to repair the alarm yourself.

Información del contacto: Please refer to the FireAngel website or your purchase documentation for the most up-to-date contact details for customer support in your region.

Documentos relacionados - CO-9X10

Preview Manual del usuario del detector de monóxido de carbono FireAngel CO-9X con 7 años de vida útil
Manual de usuario completo de la alarma de gas venenoso de monóxido de carbono FireAngel CO-9X con 7 años de vida útil. Aprenda sobre instalación, funcionamiento, mantenimiento, seguridad y solución de problemas.
Preview FireAngel FA3313, FA3322, FA3328, FA3820 Carbon Monoxide Alarm User Manual
Comprehensive user manual for FireAngel carbon monoxide alarms (models FA3313, FA3322, FA3328, FA3820), covering installation, positioning, operation, maintenance, technical specifications, warranty, and disposal.
Preview Manual de usuario de la alarma de monóxido de carbono FireAngel FA6813
Manual de usuario completo para la alarma de monóxido de carbono FireAngel FA6813, que cubre la instalación, el funcionamiento, el mantenimiento, la resolución de problemas y la información de seguridad.
Preview Manual de usuario de la alarma combinada de humo y monóxido de carbono FireAngel SCB10
Manual de usuario del FireAngel SCB10, una alarma combinada de humo y monóxido de carbono, que proporciona instrucciones completas sobre instalación, funcionamiento, mantenimiento y seguridad para uso residencial.
Preview Manual de usuario de la alarma de monóxido de carbono FireAngel FA6812/FA6813
Manual de usuario para las alarmas de monóxido de carbono (CO) FireAngel FA6812 y FA6813, que proporciona instrucciones de instalación, funcionamiento, seguridad y mantenimiento.
Preview Manual del usuario de FireAngel Multisensor Plus: Detector de humo, calor y CO
Manual de usuario completo para FireAngel Multisensor Plus y Multisensor Plus Kitchen, que detalla la instalación, el funcionamiento, la seguridad, la resolución de problemas y las especificaciones técnicas para la detección de humo, calor y monóxido de carbono.