The FireAngel CO-9X10 is a certified carbon monoxide (CO) alarm designed to provide continuous monitoring for the presence of carbon monoxide gas. Featuring an advanced electrochemical sensor developed by FireAngel, this device ensures accurate detection of CO at low concentrations, offering maximum safety for your home or workplace. It comes with a built-in lithium battery designed for a 10-year lifespan, providing reliable protection without the need for battery replacement.
This manual provides essential information on the installation, operation, maintenance, and troubleshooting of your CO-9X10 alarm. Please read it thoroughly before installation and keep it for future reference.

Figura 1: Frente view of the FireAngel CO-9X10 Carbon Monoxide Alarm. This image shows the main body of the alarm with the central test/reset button and the Power, Fault, and Alarm indicator lights.
Información importante de seguridad
Carbon monoxide (CO) is a colorless, odorless, and tasteless gas that can be fatal. This alarm is designed to detect carbon monoxide gas from any source of combustion. It is not designed to detect smoke, fire, or other gases. For optimal safety, ensure proper ventilation and regular maintenance of fuel-burning appliances.
- No pinte la alarma. Paint can clog the openings and interfere with the sensor's ability to detect CO.
- No bloquee las rejillas de ventilación de la alarma. Ensure air can freely circulate around the device.
- Test the alarm regularly. Press the test button weekly to ensure proper operation.
- Nunca ignore una alarma. If the alarm sounds, follow the "What to do if the alarm sounds" instructions immediately.
- This alarm is designed for indoor use only. Do not expose it to rain or moisture.
Contenido del paquete
Verifique el contenido del paquete para asegurarse de que todos los artículos estén presentes:
- FireAngel CO-9X10 Carbon Monoxide Alarm
- Tornillos de montaje y tacos de pared
- Manual de usuario (este documento)
Configuración e instalación
Elección de una ubicación
For optimal protection, install CO alarms in or near every room where fuel-burning appliances are located, and in sleeping areas. Consider placing an alarm on every level of your home. Avoid placing the alarm:
- Bajo la luz solar directa o cerca de fuentes de calor.
- En damp or humid areas (e.g., bathrooms).
- Within 1 meter (3 feet) of cooking appliances.
- En áreas polvorientas, sucias o grasosas.
- Detrás de cortinas o muebles.
Montaje de la alarma
The CO-9X10 can be wall-mounted or placed on a flat surface. For wall mounting:
- Select a suitable location, ideally at eye level or higher, but not directly on the ceiling unless specified by local regulations.
- Use the mounting bracket as a template to mark the drill holes on the wall.
- Drill two holes and insert the provided wall plugs.
- Screw the mounting bracket firmly to the wall.
- Attach the CO alarm to the mounting bracket by aligning the alarm with the bracket and twisting it clockwise until it clicks into place.

Figura 2: Frente detallado view of the FireAngel CO-9X10 showing the Power, Fault, and Alarm LED indicators. This view is helpful for understanding the device's status at a glance.

Figura 3: Lado view of the FireAngel CO-9X10 Carbon Monoxide Alarm, illustrating its compact profile and potential mounting features. This perspective can be useful for understanding how the device sits against a wall or on a surface.
Activación inicial
The CO-9X10 features a sealed-in lithium battery. The alarm will activate automatically when it is correctly attached to its mounting bracket. Upon activation, the green Power LED will flash once every 45 seconds, indicating normal operation.
Instrucciones de funcionamiento
Indicadores LED
- LED de alimentación verde: Parpadea una vez cada 45 segundos durante el funcionamiento normal.
- Amber Fault LED: Flashes to indicate a fault or low battery. Refer to the Troubleshooting section.
- Red Alarm LED: Flashes rapidly during a CO alarm event.
Prueba de la alarma
It is crucial to test your CO alarm weekly to ensure it is functioning correctly.
- Press and hold the large "TEST/RESET" button on the front of the alarm.
- The alarm will sound a loud, distinctive pattern (typically 4 beeps, pause, 4 beeps) and the Red Alarm LED will flash.
- Release the button. The alarm should stop sounding, and the Red Alarm LED should stop flashing.
- If the alarm does not sound or the LEDs do not respond as described, refer to the Troubleshooting section.
Qué hacer si suena la alarma
If your CO alarm sounds, it indicates the presence of carbon monoxide. Follow these steps immediately:
- Evacuar inmediatamente: Move everyone, including pets, to fresh air outdoors or open doors/windows to ventilate the area.
- Do not re-enter the premises until the alarm has stopped and the area has been ventilated.
- Llame a los servicios de emergencia: Contact your local emergency services (e.g., 999 in the UK) or a qualified gas technician to investigate the source of the CO.
- Identify and resolve the source: Do not use fuel-burning appliances until they have been checked by a professional.
Característica de silencio
The alarm may have a silence feature for nuisance alarms (e.g., from temporary high CO levels during appliance startup). Pressing the "TEST/RESET" button during an alarm may silence it for a short period. However, if the CO level remains high, the alarm will reactivate. Only use the silence feature if you are certain it is a nuisance alarm and not a genuine CO threat.
Mantenimiento
Limpieza regular
Clean your CO alarm regularly to prevent dust and debris from affecting its performance. Use a soft, damp cloth to wipe the exterior. Do not use cleaning solvents or sprays directly on the alarm.
Battery Life and End-of-Life Signal
The FireAngel CO-9X10 is equipped with a sealed-in lithium battery designed to last for 10 years. When the alarm reaches the end of its operational life, it will emit a specific end-of-life signal (e.g., two short beeps every 45 seconds, accompanied by the Amber Fault LED flashing). When this occurs, the alarm needs to be replaced immediately.
Solución de problemas
| Problema | Posible causa | Solución |
|---|---|---|
| Alarm sounds continuously (Red LED flashing) | High level of Carbon Monoxide detected. | Evacuar inmediatamente. Call emergency services. Do not re-enter until cleared by professionals. |
| Amber Fault LED flashing / Alarm chirping intermittently | Low battery or fault detected. | The battery is sealed and cannot be replaced. If the alarm is chirping due to low battery or fault, it has reached its end-of-life or is malfunctioning. Reemplace la alarma inmediatamente. |
| Alarm does not sound when Test button is pressed | Alarm malfunction or end-of-life. | Ensure the alarm is properly mounted. If it still doesn't respond, the alarm is faulty or has reached its end-of-life. Reemplace la alarma inmediatamente. |
| Green Power LED not flashing | Alarm not activated or malfunction. | Ensure the alarm is securely attached to its mounting bracket. If the issue persists, the alarm may be faulty. Reemplace la alarma. |
Presupuesto
| Característica | Detalle |
|---|---|
| Número de modelo | CO-9X10 |
| Tipo de sensor | Electroquímico |
| Fuente de poder | Sealed-in Lithium Battery (10-year life) |
| Volumen de alarma | Audible |
| Dimensiones del producto | 11.2 x 3.5 x 7.2 cm |
| Peso del artículo | 150 gramos |
| Certificaciones | BSI EN50291-1:2010 and EN50291-2:2010 Certified |
| Código Postal | 816317003609 |
Garantía y soporte
FireAngel products are manufactured to the highest standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official FireAngel website. If you experience any issues with your CO-9X10 alarm or require technical assistance, please contact FireAngel customer support. Do not attempt to repair the alarm yourself.
Información del contacto: Please refer to the FireAngel website or your purchase documentation for the most up-to-date contact details for customer support in your region.