TRU Components TC-9539292

Manual del usuario de la columna de señalización LED TRU COMPONENTS TC-9539292

Modelo: TC-9539292

Introducción

The TRU COMPONENTS TC-9539292 is a robust and durable LED signal column designed for industrial applications. It provides clear visual and audible indications for various operational states. This manual provides essential information for the safe and effective installation, operation, and maintenance of your signal column.

TRU COMPONENTS TC-9539292 LED Signal Column with red and green light segments and attached power cable.

Image: TRU COMPONENTS TC-9539292 LED Signal Column. This image displays the TRU COMPONENTS TC-9539292 LED Signal Column. The column features two distinct light segments: an upper red segment and a lower green segment. A black power cable with exposed wires at the end is shown coiled next to the column, indicating its electrical connection. The base of the signal column includes a threaded section for mounting.

Información de seguridad

Observe siempre las siguientes precauciones de seguridad para evitar lesiones y daños al dispositivo:

  • Asegúrese de que la fuente de alimentación esté desconectada antes de realizar la instalación, el mantenimiento o la solución de problemas.
  • La instalación sólo debe ser realizada por personal calificado de acuerdo con los códigos y regulaciones eléctricas locales.
  • No exponga el dispositivo a humedad excesiva, polvo o temperaturas extremas fuera de su rango operativo especificado.
  • Verifique el volumen correctotage (24 Volts) before connecting the device.
  • Do not attempt to modify or repair the device yourself. Refer to qualified service personnel.

Configuración e instalación

Follow these steps for proper installation of the signal column:

  1. Montaje: The signal column features a threaded base (M2x15, Hexagonal head style) for secure mounting. Ensure the mounting surface is stable and capable of supporting the device's weight (119 grams).
  2. Alambrado: Connect the signal column to a 24 Volt power supply. The cable includes multiple wires; refer to the specific wiring diagram provided with your equipment for correct connections to control the red and green LED segments and the audible alarm. Ensure all connections are secure and insulated.
  3. Consideraciones ambientales: Install the column in an environment that is free from excessive vibration and within the recommended operating temperature range. The material is plastic.

Instrucciones de funcionamiento

The TRU COMPONENTS signal column offers both visual and audible indications:

  • Indicación visual: The red and green LED segments can be configured for either continuous illumination or brillante. The specific control signals for these modes will depend on your system's integration.
  • Indicación audible: The integrated sounder can produce either a tono continuo o un discontinuous tone (intermittent sound). Consult your system's control logic for activating these audible alerts.

The signal column is designed to integrate with industrial control systems to provide real-time status updates.

Mantenimiento

The TRU COMPONENTS signal column is designed for durability and requires minimal maintenance. However, regular checks can extend its lifespan and ensure reliable operation:

  • Limpieza: Periodically clean the exterior of the column with a soft, damp Paño. No utilice limpiadores abrasivos ni disolventes.
  • Inspección: Regularly inspect the wiring and connections for any signs of wear, damage, or loose connections. Ensure the mounting is secure.
  • Comprobación de LED: Verify that both red and green LED segments illuminate correctly when activated.
  • Sounder Check: Confirm the sounder functions as expected when activated.

Desconecte siempre la alimentación antes de realizar cualquier mantenimiento.

Solución de problemas

If you encounter issues with your signal column, refer to the following common problems and solutions:

ProblemaPosible causaSolución
Sin luz ni sonidoSin suministro de energía; Cableado incorrecto; Unidad defectuosaCheck power connection (24V); Verify wiring against diagram; Contact support if power and wiring are correct.
Only one LED segment illuminatesIncorrect wiring for specific segment; Faulty LED segmentCheck wiring for the non-illuminating segment; If wiring is correct, the segment may be faulty.
Sounder not workingIncorrect wiring for sounder; Faulty sounderVerify sounder wiring; If wiring is correct, the sounder may be faulty.
Funcionamiento intermitenteLoose connections; Unstable power supplyCheck all wiring connections for tightness; Ensure power supply is stable.

For issues not listed above, or if solutions do not resolve the problem, please contact TRU Components customer support.

Presupuesto

Número de modeloTC-9539292
FabricanteCOMPONENTES TRU
Dimensiones (L x An x Al)10 x 10 x 15 cm
Peso119 gramos
ColorRojo, verde
MaterialPlástico
Volumentage24 voltios
Número de piezas1
Tipo de cabezaHexagonal
Sistema de mediciónMétrico
Tamaño de la rosca1/4"-20 UNC
CaracterísticasContinuous or flashing illumination, Continuous or discontinuous sounder

Garantía y soporte

TRU Components provides a Disponibilidad de repuestos durante 1 años for the TC-9539292 LED Signal Column from the date of purchase.

For technical support, warranty claims, or further assistance, please contact your point of purchase or visit the official TRU Components website. Ensure you have your model number (TC-9539292) and purchase details ready when contacting support.

Documentos relacionados - TC-9539292

Preview Hoja de datos de la luz de señalización LED USB de TRU COMPONENTS
Datos técnicos e instrucciones de funcionamiento de la luz de señalización LED USB TRU COMPONENTS (n.º de artículo 2804760), con 7 colores y función de zumbador.
Preview Manual del usuario y especificaciones técnicas del transformador LED de TRU Components
Manual de usuario completo y especificaciones técnicas para los transformadores LED de TRU Components, incluidos números de modelo, datos eléctricos, condiciones de funcionamiento y pautas de seguridad para aplicaciones de iluminación LED en interiores.
Preview Datos técnicos y de seguridad de la fuente de alimentación de carril DIN de TRU Components
Instrucciones de seguridad completas, uso previsto, explicaciones de símbolos y especificaciones técnicas para fuentes de alimentación de riel DIN de TRU Components, incluidos números de modelo y parámetros operativos.
Preview TRU COMPONENTS Carril DIN Voedingen Gebruiksaanwijzing es Especificaciones
Gedetailleerde gebruiksaanwijzing y especificaciones técnicas para el transporte en carril DIN de TRU COMPONENTS. Bevat installatie-instructions, veiligheidsinformatie y modelgegevens voor diversos uitvoeringen.
Preview Fuente de alimentación de riel DIN TRU COMPONENTS - Manual del usuario y especificaciones
Instrucciones de funcionamiento completas y especificaciones técnicas para las fuentes de alimentación de carril DIN de TRU COMPONENTS, que abarcan seguridad, instalación y datos detallados del producto. Incluye números de modelo, características eléctricas, dimensiones y directrices de seguridad.
Preview Manual de usuario y especificaciones de la fuente de alimentación de riel DIN de TRU COMPONENTS
Comprehensive user manual and technical specifications for TRU COMPONENTS DIN rail power supplies, including models DPN, DPS, and DPH series. Covers intended use, safety instructions, installation, cleaning, and detailed electrical and physical specifications.