1. Introducción
This manual provides detailed instructions for the installation, operation, and maintenance of your SEBSON IR_WAL_F Outdoor Motion Detector. This device is designed for flush wall mounting and is suitable for both outdoor and bathroom environments due to its IP65 rating. It features an infrared sensor to detect motion and automatically control connected lighting, offering adjustable detection range, light duration, and ambient light sensitivity.

Imagen 1.1: Frente view of the SEBSON IR_WAL_F Outdoor Motion Detector.
2. Instrucciones de seguridad
Lea atentamente estas instrucciones de seguridad antes de la instalación y el uso. El incumplimiento de estas instrucciones podría provocar descargas eléctricas, incendios u otros peligros.
- La instalación debe ser realizada por un electricista calificado de acuerdo con las regulaciones de cableado locales.
- Always disconnect the power supply at the main circuit breaker before performing any installation, maintenance, or repair work.
- Asegúrese de que el dispositivo esté correctamente conectado a tierra.
- Do not exceed the maximum load ratings: 1200W for incandescent bulbs and 600W for LED or other energy-saving bulbs.
- The device is IP65 rated, providing protection against dust and water jets. It is suitable for outdoor use and in wet areas, but must not be submerged in water.
- No abra ni modifique el dispositivo. No contiene piezas que puedan ser reparadas por el usuario.
3. Producto terminadoview
The SEBSON IR_WAL_F is an infrared motion detector designed for seamless integration into your wall. Its key features include:
- Sensor de movimiento infrarrojo: Detects movement based on heat radiation.
- Flush Wall Mount Design: For discreet and integrated installation.
- Área de detección amplia: Up to 10 meters range with a 190-degree angle.
- Adjustable Light Duration: Configurable from 10 seconds to 30 minutes, or permanent ON/OFF.
- Adjustable Ambient Light Sensitivity: Operates between 3 LUX (dark) and 2,000 LUX (daylight).
- Compatibilidad de LED: Suitable for use with LED and incandescent light sources.
- Clasificación IP65: Proporciona protección contra la entrada de polvo y chorros de agua a baja presión desde cualquier dirección.

Imagen 3.1: Másview of key features including detection range, LED compatibility, IP rating, light duration, LUX sensitivity, and voltage.

Imagen 3.2: Explosión view showing the main components of the motion detector.
4. Especificaciones
| Característica | Especificación |
|---|---|
| Fabricante | SEBSON |
| Número de modelo | IR_WAL_F |
| Dimensiones del producto | 8.6 x 8.6 x 6.3 cm |
| Dimensiones de instalación | 53 x 53 x 23 mm |
| Peso | 125 gramos |
| Color | Blanco |
| Material | Plástico |
| Fuente de poder | AC |
| Volumentage | 230 voltios |
| Máxima potencia (incandescente) | 1200 vatios |
| Max Power (LED/Energy-saving) | 600 vatios |
| Método de instalación | Wall Mount (Flush) |
| Compatibilidad del tipo de bombilla | CONDUJO |
| Área de detección | Max. 10m / 190° |
| Tipo de interruptor | Interruptor deslizante |
| Características especiales | LED compatible, IP65, Programmable, 190° detection, ON/OFF switch |
| Temperatura de funcionamiento | 40°C |
5. Instalación
Follow these steps for proper installation of the motion detector. It is recommended that installation be carried out by a qualified electrician.
5.1. Preparación
- Asegúrese de que el suministro de energía principal al área de instalación esté apagado en el disyuntor.
- Prepare a standard flush-mount wall box (53x53x23mm minimum internal dimensions) at the desired installation height (recommended 1m - 1.8m for optimal detection).
5.2. Montaje y cableado
- Carefully remove the front cover of the motion detector to access the wiring terminals and mounting plate.
- Connect the electrical wires to the terminals as shown in the wiring diagram below. Ensure correct connections for Live (L), Neutral (N), and Switched Live (L') to the light fixture.
- Secure the main sensor unit into the flush-mount wall box using appropriate screws.
- Reattach the front cover to the sensor unit.

Image 5.1: Wiring diagram for the SEBSON IR_WAL_F motion detector.

Image 5.2: Product dimensions and flush mounting illustration.
5.3. Detection Area
The sensor has a detection range of up to 10 meters and a 190-degree angle. The optimal installation height is between 1m and 1.8m. Consider the placement to avoid false triggers from moving objects or heat sources.

Image 5.3: Diagram illustrating the detection range and angle of the motion detector.
6. Operación
Once installed and powered on, the motion detector will automatically control the connected lighting based on its settings. The sensor activates the light when motion is detected within its range and the ambient light level is below the set LUX threshold. The light will then remain on for the duration set by the TIME control.
7. Ajuste de configuración
The motion detector features two adjustable controls: TIME and LUX. These controls are typically located behind the front cover of the sensor unit.

Imagen 7.1: View of the adjustment dials for TIME and LUX settings.
- TIEMPO (Duración de la luz): This dial adjusts how long the connected light remains on after motion is detected and no further motion is sensed. The settings typically range from 10 seconds to 30 minutes. There may also be an option for permanent ON or OFF. Turn the dial clockwise to increase the duration and counter-clockwise to decrease it.
- LUX (sensibilidad a la luz ambiental): This dial sets the ambient light threshold. The sensor will only activate the light if the surrounding natural light level is below this set value. The range is typically from 3 LUX (very dark, only activates at night) to 2,000 LUX (daylight, activates regardless of natural light). Turn the dial towards the sun symbol for higher sensitivity (activates in brighter conditions) and towards the moon symbol for lower sensitivity (activates only in darker conditions).
8. Mantenimiento
To ensure optimal performance and longevity of your motion detector, follow these simple maintenance guidelines:
- Limpieza: Periodically clean the surface of the sensor, especially the lens, with a soft, dry, lint-free cloth.
- Evite los productos químicos: Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the plastic housing or the sensor lens.
- Comprobación de obstrucciones: Ensure that the sensor lens is clear of any obstructions such as dirt, spiderwebs, or vegetation that could interfere with its detection capabilities.
- Apagado para limpieza profunda: If a more thorough cleaning is required, always disconnect the power supply before proceeding.
9. Solución de problemas
If you encounter issues with your SEBSON motion detector, refer to the following common problems and solutions:
| Problema | Posible causa | Solución |
|---|---|---|
| La luz no se enciende cuando se detecta movimiento. | Sin suministro de energía bombilla defectuosa Cableado incorrecto LUX setting too high TIME setting too short | Verifique la conexión eléctrica y el disyuntor. Reemplace la bombilla. Verifique el cableado contra el diagrama (Sección 5.2). Adjust LUX setting to a lower value (towards moon symbol). Increase TIME setting. |
| La luz permanece encendida continuamente. | TIME setting on permanent ON Continuous motion in detection area Sensor averiado | Adjust TIME setting to a timed duration. Remove obstructions or reposition sensor. Comuníquese con el soporte técnico si el problema persiste. |
| Light turns on randomly without apparent motion. | Environmental factors (e.g., moving branches, small animals, heat sources) Alta sensibilidad | Reposition sensor to avoid interference. Adjust sensitivity (if available) or reposition. |
| Detection range is too short or too long. | Altura de instalación incorrecta Obstrucciones Ajustes de sensibilidad | Adjust installation height (refer to Section 5.3). Clear obstructions from detection path. Check if there are sensitivity adjustments (not explicitly mentioned for this model, but common). |
10. Garantía y soporte
SEBSON products are manufactured with quality and reliability in mind. For information regarding warranty coverage, please refer to the documentation provided with your purchase or visit the official SEBSON website. If you require technical assistance or have questions not covered in this manual, please contact SEBSON customer support.