1. Introducción
This manual provides detailed instructions for the safe and effective operation of your Jaycar Digitech QC1938 100MHz Digital Oscilloscope. Please read this manual thoroughly before using the device to ensure proper setup, operation, and maintenance. Retain this manual for future reference.
2. Información de seguridad
Observe the following safety precautions to prevent injury and avoid damage to the instrument or any products connected to it.
- Fuente de energía: Connect the oscilloscope only to the power source specified in this manual.
- Toma de tierra: Asegúrese de que el instrumento esté correctamente conectado a tierra para evitar descargas eléctricas.
- Sondas: Use only probes supplied or recommended by the manufacturer. Ensure probes are rated for the voltagy siendo medido.
- Ventilación: No obstruya las aberturas de ventilación. Asegúrese de que haya un flujo de aire adecuado alrededor del instrumento.
- Ambiente: Operate the oscilloscope in a dry environment. Avoid exposure to moisture, dust, or extreme temperatures.
- Servicio: Encargue cualquier reparación a personal técnico cualificado. No intente reparar el instrumento usted mismo.
3. Contenido del paquete
Verifique que todos los artículos que se enumeran a continuación estén presentes en su paquete:
- Jaycar Digitech QC1938 Digital Oscilloscope
- 10:1 Passive Probe with 1.5m lead
- 2 x BNC to Clip Test Leads
- Cable USB
- Cable de alimentación
- Manual de usuario (este documento)
4. Producto terminadoview
The Jaycar Digitech QC1938 is a 100MHz Digital Oscilloscope designed for precise electronic measurements. It features a 7-inch color LCD screen, two independent channels, and a built-in waveform generator.



Características principales:
- 7-inch TFT color LCD screen with 800 x 480 pixel resolution
- Two independent input channels
- 100MHz bandwidth and 1GSa/s samptasa de ling
- 8M memory depth (single channel)
- Integrated 25MHz waveform generator (Sine, Square, Ramp, Exponential, Noise, DC)
- Auto scale function for automatic sine and square wave detection
- 14 trigger modes including Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, and IIC
- 5 serial protocol triggers and decodes: RS232/UART, I2C, SPI, CAN, and LIN
- Two 3-digit digital voltmeters and a 6-digit hardware frequency indicator
- 32 types of auto measurements with real-time statistics
- USB Host/Device interface for computer control and data storage
5. Configuración
5.1 Conexión de alimentación
- Connect the supplied power lead to the power input on the rear panel of the oscilloscope.
- Plug the other end of the power lead into a grounded AC power outlet.
- Presione el botón de encendido en el panel frontal para encender el osciloscopio.
5.2 Conexión de sonda
- Connect the BNC connector of the passive probe to either Channel 1 (CH1) or Channel 2 (CH2) input on the front panel.
- Conecte la pinza de tierra de la sonda al punto de tierra del circuito.
- Connect the probe tip to the test point in your circuit.
- Ensure the probe's attenuation setting (e.g., 1X or 10X) matches the setting on the oscilloscope for accurate readings.
6. Instrucciones de funcionamiento
6.1 Funcionamiento básico
- Auto Scale: Press the 'AUTO SET' button to automatically adjust vertical, horizontal, and trigger settings for a stable waveform display. This function detects sine and square waves automatically.
- Vertical Controls (VOLTS/DIV, POSITION): Use the VOLTS/DIV knobs to adjust the vertical scale (voltage per division) for each channel. The POSITION knobs shift the waveform vertically.
- Horizontal Controls (SEC/DIV, POSITION): Use the SEC/DIV knob to adjust the horizontal scale (time per division). The horizontal POSITION knob shifts the waveform horizontally.
- Nivel de disparo: Adjust the 'TRIGGER LEVEL' knob to set the voltage level at which the oscilloscope captures a waveform.
6.2 funciones avanzadas
- Generador de forma de onda: Access the waveform generator menu to select and configure output waveforms such as Sine, Square, Ramp, Exponential, Noise, and DC. Connect the 'WAVE GEN' output to your circuit.
- Modos de disparo: Utilize the 14 available trigger modes (Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC) to capture specific events. Select modes via the 'TRIGGER' menu.
- Decodificación del protocolo serie: The oscilloscope supports decoding for RS232/UART, I2C, SPI, CAN, and LIN protocols. Configure these settings in the 'DECODE' menu to view decoded data.
- Medidas: The device offers 32 types of automatic measurements with real-time statistics (maximum, minimum, standard deviation, etc.). Access these via the 'MEASURE' menu.
- Conectividad USB: Connect a USB thumb drive to the USB Host port to save oscilloscope setups, waveforms, reference waveforms, CSV files, and images. The USB Device port allows for remote control from a computer using SCPI commands.
7. Mantenimiento
7.1 Limpieza
Para limpiar el instrumento, utilice un paño suave.ampLimpie con una solución de detergente suave. No utilice limpiadores abrasivos ni disolventes que puedan dañar el...asing o pantalla. Asegúrese de que el dispositivo esté apagado y desenchufado antes de limpiarlo.
7.2 Almacenamiento
When not in use, store the oscilloscope in a dry, dust-free environment away from direct sunlight and extreme temperatures. Use the original packaging or a suitable case for protection during transport.
8. Solución de problemas
If you encounter issues with your oscilloscope, refer to the following common problems and solutions:
| Problema | Posible causa | Solución |
|---|---|---|
| Sin poder | Power cable not connected; Power outlet faulty; Power button not pressed | Check power cable connection; Test power outlet; Press power button firmly |
| No se muestra ninguna forma de onda | Probe not connected; Incorrect input channel selected; Vertical/Horizontal scale incorrect; Trigger level too high/low | Connect probe to CH1/CH2; Select correct channel; Adjust VOLTS/DIV and SEC/DIV; Adjust TRIGGER LEVEL or use 'AUTO SET' |
| Forma de onda inestable | Incorrect trigger settings; No stable trigger source | Adjust trigger level; Select appropriate trigger mode; Ensure a stable signal source |
| Unidad USB no reconocida | USB drive formatted incorrectly; Drive not fully inserted | Ensure USB drive is FAT32 formatted; Re-insert USB drive firmly |
Si el problema persiste después de intentar estas soluciones, comuníquese con el servicio de atención al cliente.
9. Especificaciones
| Parámetro | Especificación |
|---|---|
| Mostrar | LCD en color TFT de 7 pulgadas |
| Resolución | 800 x 480 píxeles |
| Tipo de pantalla | Point, Vector |
| Canales | 2 |
| Ancho de banda | 100 MHz |
| Samptasa de ling | Hasta 1 GSa/s |
| Profundidad de la memoria | 8M (single channel) |
| Rango vertical | 2mV / div ~ 10V / div |
| Resolución vertical | 8 bits |
| Generador de forma de onda | Seno, cuadrado, Ramp, Exponential, Noise, DC |
| Interfaz | Host USB, dispositivo USB |
| Peso | 1.9 kilogramos |
| Dimensiones (L x Al x An) | 318 mm x 150 mm x 110 mm |
10. Garantía y soporte
Para obtener información sobre la garantía y asistencia técnica, consulte la documentación proporcionada al momento de la compra o póngase en contacto con su distribuidor. Conserve el comprobante de compra para reclamaciones de garantía.