Trane B0BW541NLS

Manual del usuario de Trane Control Limit 220F

Model: B0BW541NLS

1. Producto terminadoview

The Trane Control Limit 220F is a genuine OEM (Original Equipment Manufacturer) part designed for commercial HVAC units. This component functions as a temperature limit control, ensuring the safe operation of heating and cooling systems by preventing temperatures from exceeding a specified threshold of 220°F.

It is crucial to use genuine OEM parts for safety, reliability, and optimal performance of your Trane HVAC equipment.

1.1. ¿Qué hay en la caja?

1.2. Características del producto

Trane Control Limit 220F, front view with orange wires and white connector

Figura 1.1: Frente view of the Trane Control Limit 220F, showing the metallic disc, mounting bracket, orange wires, and white electrical connector.

2. Información de seguridad

ADVERTENCIA: Always disconnect power to the HVAC unit before attempting any installation, maintenance, or repair. Failure to do so can result in serious injury or death from electrical shock.

3. Configuración e instalación

This section provides general guidelines for installing the Trane Control Limit 220F. Always refer to the specific service manual for your Trane HVAC unit for precise installation instructions and wiring diagrams.

3.1. Herramientas necesarias

3.2. Pasos de instalación

  1. Desconectar la energía: Locate the main power switch for the HVAC unit and turn it OFF. Verify power is off using a multimeter.
  2. Componente de acceso: Open the access panel of the HVAC unit to locate the existing limit control.
  3. Cableado de documentos: Before disconnecting, take a photograph or make a diagram of the existing wiring connections to the limit control. This will aid in correct re-installation.
  4. Eliminar componente antiguo: Carefully disconnect the wires from the old limit control and unmount it from its position.
  5. Instalar nuevo componente: Mount the new Trane Control Limit 220F in the same location as the old one. Ensure it is securely fastened.
  6. Conectar el cableado: Connect the wires to the new limit control according to your documented diagram. Ensure all connections are tight and secure. The white connector should snap firmly into place.
  7. Panel de acceso seguro: Cierre y asegure el panel de acceso de la unidad HVAC.
  8. Restaurar energía y prueba: Restore power to the HVAC unit. Perform system checks to ensure the unit operates correctly and the limit control functions as expected.
Trane Control Limit 220F, top view with coiled orange wires and white connector

Figura 3.1: Arriba view of the Trane Control Limit 220F, showing the compact arrangement of the orange wires and the white connector, ready for installation.

Trane Control Limit 220F, side view showing the metallic disc and electrical connections

Figura 3.2: Lado view of the Trane Control Limit 220F, highlighting the metallic disc and the points where the orange wires connect to the control unit.

4. Operación

The Trane Control Limit 220F is a safety device designed to monitor the temperature within the HVAC system. Its primary function is to open an electrical circuit if the temperature exceeds 220°F, thereby shutting down the heating element or other components to prevent damage or hazardous conditions.

Note: Frequent activation of the limit control indicates an underlying issue with the HVAC system that requires investigation by a qualified technician.

5. Mantenimiento

The Trane Control Limit 220F is a robust component designed for long-term reliability. Regular maintenance of the overall HVAC system is recommended to ensure its proper function and longevity.

Do not attempt to clean the internal components of the limit control or apply any lubricants. This can impair its function.

6. Solución de problemas

If your HVAC unit is experiencing issues related to temperature control or unexpected shutdowns, the limit control may be involved. This section provides general troubleshooting steps. For complex issues, always consult a qualified HVAC technician.

SíntomaPosible causaAcción recomendada
HVAC unit frequently shuts down unexpectedly.Overheating due to restricted airflow, dirty filters, faulty blower, or other system issues causing high temperatures.Check air filters and replace if dirty. Ensure vents are open. Inspect blower motor for proper operation. If issues persist, contact a technician to diagnose the root cause of overheating.
HVAC unit does not turn on (no heat/cooling).Limit control is open (tripped) and not resetting, or it has failed.Ensure power is off. Visually inspect the limit control for damage. A technician can test the continuity of the limit control. If it's open at normal temperatures, it may need replacement.
Unit runs continuously without reaching desired temperature.Unlikely to be the limit control itself, but rather a heating element issue, thermostat problem, or other system component.Consult the HVAC unit's service manual or a qualified technician for diagnosis.

Importante: Do not attempt to bypass the limit control for troubleshooting. This is a critical safety device.

7. Especificaciones

AtributoValor
Nombre del productoTrane Control Limit 220F
Tipo de piezaLimit Switch / Temperature Control
Temperatura de activación220°F (Fixed)
FabricanteTrane
ASINB0BW541NLS
Dimensiones del producto11 x 9 x 2 pulgadas (dimensiones aproximadas del paquete)
Peso del artículo8 ounces (approximate package weight)
Primera fecha disponible18 de febrero de 2023
Trane Control Limit 220F, angled view showing the metallic disc and part of the orange wiring

Figura 7.1: Angulado view of the Trane Control Limit 220F, illustrating its compact design and robust construction.

8. Garantía y soporte

As a genuine OEM part, the Trane Control Limit 220F is covered by Trane's standard warranty for replacement parts. Specific warranty terms and conditions may vary. Please retain your proof of purchase.

For technical support, warranty claims, or to locate an authorized Trane service provider, please contact Trane customer service or visit the official Trane websitio:

When contacting support, please have your product model (B0BW541NLS) and purchase date available.

Documentos relacionados - B0BW541NLS

Preview Catálogo completo de diseño de sistemas de agua fría de Trane
Catálogo completo de Trane para el diseño de sistemas avanzados de agua fría. Esta guía detalla los componentes del sistema, los principios de diseño más avanzados, las configuraciones y los criterios de selección para enfriadoras, torres de refrigeración, bombas y válvulas de control. Se centra en lograr eficiencia, fiabilidad y rentabilidad en aplicaciones de climatización comerciales e industriales, incluyendo información sobre Tracer Chiller Plant Control y Trane Design Assist.
Preview Guía de solución de problemas del termostato Trane: Solución de problemas comunes de HVAC
Aprenda a solucionar problemas comunes de termostatos Trane y del sistema HVAC. Esta guía ofrece soluciones paso a paso para fallos de termostatos, averías del sistema HVAC y discrepancias en la configuración de temperatura.
Preview Bombas de calor compactas para techo Trane Precedent™ de alta eficiencia: Catálogo de productos
Descubra la serie Trane Precedent™ de bombas de calor compactas para techo de alta eficiencia, diseñadas para una fiabilidad excepcional y un control avanzado del confort. Este catálogo detalla las características, especificaciones y aplicaciones de unidades de 12.5 a 25 toneladas, lo que demuestra el compromiso de Trane con la calidad y el rendimiento en soluciones de climatización comercial.
Preview Enfriadora refrigerada por aire Trane Ascend™ ACR: Refrigeración de alta densidad para centros de datos
Discover the Trane Ascend™ Air-Cooled Chiller (ACR) model, engineered for high-density data centers and commercial buildings. Features include high ambient temperature operation up to 145°F, integrated free cooling, rapid restart, and advanced Symbio® 800 controls for efficiency and reliability.
Preview Manual de productos Trane 2025: Sistemas HVAC residenciales y comerciales ligeros
Descubra el Manual de Producto Trane 2025, una guía completa para sistemas de climatización residenciales y comerciales ligeros. Incluye aires acondicionados, hornos, bombas de calor, climatizadores, serpentines, termostatos y productos para la calidad del aire interior (IAQ), con especificaciones para refrigerantes R-410A y de bajo PCA.
Preview Guía de instalación del sensor de temperatura del aire del conducto de suministro Trane BAYSENSC360
Guía de instalación para el sensor de temperatura del aire del conducto de suministro Trane BAYSENSC360, que detalla seguridad, inspección, información general, contenido del kit, procedimientos de instalación para aplicaciones de hornos/serpentines y manipuladores de aire, y una resistencia/volumen.tagmi mesa