Sygonix SY-5231014

Sygonix SY-5231014 Fingerprint/RFID Access System

Manual de usuario

Modelo: SY-5231014

1. Introducción

This manual provides essential information for the installation, operation, and maintenance of your Sygonix SY-5231014 Fingerprint/RFID Access System. This advanced access control unit features a vandal-proof metal housing, an illuminated keypad, and supports multiple access methods including fingerprint, RFID card, and PIN codes. It is designed for recessed installation and offers robust security with an IP55 rating, making it suitable for various indoor and outdoor applications. The system can manage up to 1000 users, including 10 designated visitors.

2. Instrucciones de seguridad

Lea y comprenda todas las instrucciones de seguridad antes de instalar y utilizar el dispositivo. Si no las sigue, podría sufrir una descarga eléctrica, un incendio o daños en el dispositivo.

  • Seguridad eléctrica: Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Ensure power is disconnected before any wiring work.
  • Fuente de alimentación: Use only a compatible 12V/DC or 18V/DC power supply. Incorrect voltagPuede dañar la unidad.
  • Condiciones ambientales: The unit has an IP55 rating, indicating protection against dust ingress and low-pressure water jets. Avoid direct exposure to heavy rain, submersion, or extreme temperatures.
  • Vandalism Protection: While designed with a vandal-proof metal casing, extreme force can still cause damage.
  • Mantenimiento: No intente reparar la unidad usted mismo. Encargue cualquier servicio técnico a personal cualificado.

3. Contenido del paquete

Desempaque la caja con cuidado y asegúrese de que todos los artículos enumerados a continuación estén presentes y sin daños. Si falta algún artículo o está dañado, contacte con su vendedor inmediatamente.

  • Sygonix SY-5231014 Access System Unit
  • Plastic Mounting Box (for recessed installation)
  • Tornillos y tacos de montaje
  • 30 cm Connection Cable for Access Control
  • Diodo
  • Llave hexagonal (llave Allen)
  • Manual de usuario (este documento)
All components of the Sygonix SY-5231014 access system, including the main unit, recessed mounting box, screws, cable, diode, and hex key.
Figura 3.1: Sobreview of all included components for the Sygonix SY-5231014 access system. This image displays the main access control unit, the plastic recessed mounting box, various screws and wall plugs, the pre-wired connection cable, a diode, and a hex key for installation.

4. Configuración e instalación

The Sygonix SY-5231014 is designed for recessed installation. Proper installation is crucial for optimal performance and security.

4.1 Montaje de la unidad

  1. Preparar la apertura: Create an appropriate opening in the wall or mounting surface to accommodate the plastic mounting box. Ensure sufficient depth for the unit and wiring.
  2. Install Mounting Box: Secure the plastic mounting box into the prepared opening using the provided screws and plugs. Ensure it is flush with the surface.
  3. Conectar el cableado: Refer to the wiring diagram (not provided in this text, refer to the full product manual for detailed diagrams) for connecting the power supply (12V/DC or 18V/DC), electric lock, and Wiegand interface if applicable. The included 30 cm cable facilitates these connections. Ensure all connections are secure and insulated.
  4. Insert Diode: If connecting to an inductive load (e.g., an electric strike), install the provided diode across the lock terminals to protect the access controller from back-EMF.
  5. Unidad principal segura: Carefully insert the main access control unit into the mounting box. Secure it using the provided screws, typically located on the front panel.
Frente view of the Sygonix SY-5231014 access system with its recessed mounting box.
Figure 4.1: The Sygonix SY-5231014 access system, showing the main unit with its illuminated keypad and fingerprint reader, alongside the plastic recessed mounting box. This illustrates how the unit fits into its housing for installation.
Frente view of the Sygonix SY-5231014 access system and its recessed mounting box, separated.
Figura 4.2: Una clara view of the Sygonix SY-5231014 access system's front panel, featuring the numeric keypad and fingerprint sensor, presented next to its empty recessed mounting box. This highlights the design for flush installation.
Trasero view of the Sygonix SY-5231014 access system, showing the wiring harness.
Figure 4.3: The rear side of the Sygonix SY-5231014 access system, displaying the multi-colored wiring harness extending from the unit. This view is crucial for understanding the electrical connections required during installation.

5. Instrucciones de funcionamiento

The Sygonix SY-5231014 offers various methods for granting access and managing users.

5.1 Gestión de usuarios

The system supports up to 1000 users, comprising 990 general users and 10 visitor users. User access can be granted via PIN, RFID card, or fingerprint.

  • Agregar usuarios: Access the programming mode (refer to the full manual for specific programming codes and sequences). Select the option to add a new user. Follow the prompts to register a PIN, scan an RFID card, or enroll a fingerprint.
  • Eliminación de usuarios: In programming mode, select the option to delete a user. You may need to enter the user's ID or present their access credential to remove them from the system.
  • Usuarios visitantes: Visitor users typically have time-limited or single-use access. Configure these settings within the programming mode.

5.2 Acceso al Sistema

  • PIN Access: Enter your registered PIN code on the illuminated keypad, then press the '#' key.
  • Acceso con tarjeta RFID: Present your registered RFID card to the designated reader area on the unit.
  • Acceso mediante huella dactilar: Coloque su dedo registrado firmemente sobre el sensor de huellas dactilares.

Upon successful authentication, the relay will activate according to its configured mode (impulse or toggle), granting access.

5.3 Keypad Illumination

The keypad features illumination for improved visibility in low-light conditions. This feature is automatically active or can be configured within the system settings.

5.4 Relay Modes

The programmable relay can operate in either impulse or toggle mode:

  • Modo de impulso: The relay activates for a short, configurable duration (e.g., 1-99 seconds) after successful authentication, typically used for electric strikes or momentary lock releases.
  • Modo de alternancia: The relay changes its state (ON to OFF, or OFF to ON) with each successful authentication, suitable for applications requiring a persistent state change, such as holding a door open until another authentication.

6. Mantenimiento

Regular maintenance ensures the longevity and reliable operation of your access system.

  • Limpieza: Utilice un paño suave y seco.amp cloth to clean the keypad and fingerprint sensor. Avoid abrasive cleaners, solvents, or excessive moisture. Ensure the fingerprint sensor is free of dirt and smudges for accurate readings.
  • Inspección: Periodically check the unit for any signs of physical damage, loose connections, or wear.
  • Actualizaciones de software: Verifique el fabricante websitio para obtener actualizaciones de firmware disponibles que puedan mejorar el rendimiento o agregar funciones.

7. Solución de problemas

If you encounter issues with your Sygonix SY-5231014, refer to the following common problems and solutions.

  • La unidad no se enciende:
    Posible causa: No hay fuente de alimentación o cableado incorrecto.
    Solución: Verify the power supply is connected and providing the correct voltage (12V/DC or 18V/DC). Check all wiring connections for continuity and proper polarity.
  • Access Denied (PIN/Card/Fingerprint):
    Posible causa: Incorrect PIN, unregistered card/fingerprint, or sensor obstruction.
    Solución: Ensure the correct PIN is entered. Verify the RFID card or fingerprint is registered in the system. Clean the fingerprint sensor thoroughly. Re-enroll fingerprint if issues persist.
  • El teclado no responde:
    Posible causa: System freeze or internal fault.
    Solución: Disconnect power to the unit for 30 seconds, then reconnect to perform a soft reset. If the issue persists, contact technical support.
  • La puerta no se desbloquea:
    Posible causa: Lock malfunction, incorrect relay settings, or wiring issue.
    Solución: Check the electric lock for proper function. Verify the relay mode (impulse/toggle) and duration settings. Inspect wiring between the access unit and the lock.
  • La iluminación no funciona:
    Posible causa: Feature disabled or internal fault.
    Solución: Check system settings to ensure keypad illumination is enabled. If enabled and still not working, contact technical support.

8. Especificaciones

CaracterísticaEspecificación
ModeloSY-5231014
MarcaSygonix
Métodos de accesoFingerprint, RFID Card, PIN Code
Capacidad del usuarioUp to 1000 (990 General, 10 Visitor)
Fuente de alimentación12V/DC to 18V/DC
Clasificación de protecciónIP55
InterfazWiegand 26/44
TecladoIluminado
Material de la carcasaVandal-proof Metal

9. Garantía y soporte

For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official Sygonix webSitio. Conserve su comprobante de compra para reclamaciones de garantía.

Documentos relacionados - SY-5231014

Preview Cerradura RFID/Código Sygonix IP66 Códigos de programaciónview
Este documento proporciona unaview de los códigos de programación para Sygonix RFID/Code Lock IP66, detallando funciones de configuración, formatos de entrada y parámetros predeterminados.
Preview Instrucciones de funcionamiento de la cerradura Sygonix RFID/Code IP66
Instrucciones de funcionamiento completas para la cerradura Sygonix RFID/Code IP66, que detallan la instalación, la programación, las características y las pautas de seguridad.
Preview Instrucciones de funcionamiento de la cerradura Sygonix RFID/Code IP66
Comprehensive operating instructions for the Sygonix RFID/Code Lock IP66, detailing installation, programming, features, and safety guidelines for secure access control.
Preview Sistema de control de acceso RFID Sygonix SY-6097868 con lector de huellas dactilares - Manual del usuario
Manual de usuario del sistema de control de acceso RFID Sygonix SY-6097868 con lector de huellas dactilares. Describe su propósito, contenido, precauciones de seguridad, instalación, cableado, programación y resolución de problemas.
Preview Sygonix RFID/Fingerprint Access System Operating Instructions
Operating instructions for the Sygonix RFID/Fingerprint Access System (Item no. 2380476), detailing intended use, safety information, installation, programming, and technical specifications.
Preview Sygonix RFID/Codeschloss IP66 Bedienungsanleitung
Bedienungsanleitung für das Sygonix RFID/Codeschloss IP66, inklusive Funktionen, Montage, Anschluss und Programmierung.