1. Introducción
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the AKO AKO-15692 Three-Phase PROPlus Basic Electronic Control Panel with Defrost 10200W. Please read this manual thoroughly before installation and operation.

Figura 1: Frente view of the AKO AKO-15692 control panel. This image displays the front of the AKO AKO-15692 control panel. On the left, a digital display shows '-19.4' with 'ECO' and defrost indicators. Below the display are navigation buttons (up, down, set, escape, power, question mark, light). The right side features a transparent hinged cover, revealing internal circuit breakers and a rotary switch.
2. Información de seguridad
Observe siempre las siguientes precauciones de seguridad para evitar lesiones y daños al dispositivo:
- La instalación y el mantenimiento deben ser realizados únicamente por personal calificado.
- Disconnect power before performing any work on the control panel.
- Asegure una conexión a tierra adecuada para evitar descargas eléctricas.
- Do not expose the unit to moisture or extreme temperatures outside its operating range.
- Verifique que todas las conexiones sean seguras y correctas antes de aplicar energía.
3. Producto terminadoview
The AKO-15692 is a three-phase electronic control panel designed for refrigeration systems requiring defrost management. It integrates control, protection, and monitoring functions for optimal performance and energy efficiency.
Características principales:
- Three-phase power compatibility (up to 10200W).
- Integrated defrost control.
- Digital display for temperature and status.
- User-friendly control interface.
- Robust enclosure for industrial environments.
4. Configuración e instalación
4.1 Desembalaje
Carefully unpack the control panel and inspect it for any signs of damage. Retain the packaging materials for future transport or storage.
4.2 Montaje
The unit is designed for screw-mounted installation. Choose a dry, well-ventilated location away from direct heat sources or excessive vibration. Ensure sufficient space for wiring and ventilation.
- Mark the mounting points on the wall using the panel's dimensions.
- Perfore los agujeros apropiados e inserte tacos de pared si es necesario.
- Secure the control panel to the wall using suitable screws.
4.3 Conexiones eléctricas
All electrical connections must comply with local and national electrical codes. Refer to the wiring diagram provided inside the panel cover for specific connections.
- Fuente de alimentación: Connect the three-phase power supply to the designated terminals.
- Compresor: Connect the compressor load to the appropriate output terminals.
- Defrost Heaters: Connect defrost heaters to their dedicated output terminals.
- Sensores: Connect temperature sensors to the specified input terminals.
- Toma de tierra: Ensure all grounding connections are properly made.
Warning: Incorrect wiring can lead to severe damage or electrical shock. Consult a qualified electrician if unsure.
5. Instrucciones de funcionamiento
5.1 Encendido / Apagado
Presione el ⏻ (Power) button to turn the unit on or off. The digital display will illuminate upon power-on.
5.2 Pantalla y navegación
The digital display shows the current temperature or system status. Use the following buttons for navigation and settings:
- CONJUNTO: Ingresar/confirmar configuración.
- ▲ (Arriba): Increase values or navigate up.
- ▼ (Abajo): Decrease values or navigate down.
- ESCAPE: Exit menu or cancel operation.
- ?: Access help or information.
- ☀︎ (Light): Control internal light (if applicable) or display brightness.
5.3 Ajuste de temperatura
- Presione el COLOCAR button. The current setpoint will flash.
- Utilice el ▲ or ▼ botones para ajustar la temperatura deseada.
- Prensa COLOCAR again to confirm the new setpoint.
5.4 Ciclo de descongelación
The unit features automatic defrost control. Parameters such as defrost interval and duration can be configured through the settings menu. Consult the detailed programming section in the full manual for advanced configurations.
6. Mantenimiento
Regular maintenance ensures optimal performance and longevity of the control panel.
6.1 Limpieza
- Desconecte la alimentación antes de limpiar.
- Limpie el exterior con un paño suave y seco.amp Paño. No utilice limpiadores abrasivos ni disolventes.
- Asegúrese de que no entre humedad en los componentes internos.
6.2 inspecciones
Inspeccione periódicamente lo siguiente:
- Alambrado: Compruebe si hay cables sueltos o dañados.
- Terminales: Asegúrese de que todas las conexiones de los terminales estén bien ajustadas.
- Recinto: Look for any signs of physical damage or corrosion.
- Ventilación: Asegúrese de que las aberturas de ventilación estén limpias y sin obstrucciones.
7. Solución de problemas
Esta sección aborda problemas comunes. Para problemas más complejos, contacte con el soporte técnico.
| Problema | Posible causa | Solución |
|---|---|---|
| El panel no se enciende. | No hay suministro de energía; fusible quemado/disyuntor disparado. | Check main power supply; Inspect fuses/breakers and reset if necessary. |
| Lectura de temperatura incorrecta. | Faulty sensor; Sensor incorrectly placed. | Check sensor connections; Verify sensor placement; Replace sensor if faulty. |
| Defrost not initiating. | Incorrect defrost settings; Defrost heater fault. | Review defrost parameters in settings; Check defrost heater and wiring. |
8. Especificaciones
| Característica | Detalle |
|---|---|
| Modelo | AKO-15692 |
| Marca | AKO |
| Potencia nominal | 10200 W |
| Fase | Trifásico |
| Tipo de instalación | Atornillado |
| Función de descongelación | Integrado |
9. Garantía y soporte
9.1 Información de garantía
AKO products are covered by a standard manufacturer's warranty. Please refer to the warranty card included with your purchase or visit the official AKO websitio para conocer los términos y condiciones detallados.
9.2 Soporte técnico
For technical assistance, spare parts, or service inquiries, please contact AKO customer support. Have your model number (AKO-15692) and purchase date ready when contacting support.
Contact information (e.g., phone, email, website) can typically be found on the product packaging or the official AKO websitio.