Introducción
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Reznor UDXC-45 Natural Gas Unit Heater. Please read this manual thoroughly before installation or use and retain it for future reference. This unit is designed for indoor use in commercial, industrial, or residential spaces such as garages, workshops, and warehouses.
Información de seguridad
ADVERTENCIA: La instalación, el ajuste, la alteración, el servicio o el mantenimiento incorrectos pueden causar daños a la propiedad, lesiones o la muerte. Lea detenidamente las instrucciones de instalación, funcionamiento y mantenimiento antes de instalar o reparar este equipo.
- Installation must comply with local and state codes. It is highly recommended that installation and service be performed by a qualified installer, service agency, or gas supplier.
- Asegúrese de que haya una ventilación adecuada en el área de instalación.
- No almacene ni utilice gasolina u otros vapores y líquidos inflamables cerca de este o cualquier otro aparato.
- Este producto puede exponerlo a sustancias químicas que incluyen plomo y compuestos de plomo, que en el estado de California se sabe que causan cáncer y defectos de nacimiento u otros daños reproductivos. Para obtener más información, visite www.P65Warnings.ca.gov.
Características del producto
- Capacidad de calentamiento: 45,000 BTU with two heating output levels (low fire 26,145 BTU / high fire 37,350 BTU).
- Eficiencia térmica: Alcanza una calificación de eficiencia térmica del 83%.
- Intercambiador de calor: TCORE2 titanium-stabilized aluminized steel heat exchanger for durability.
- Combustion: Patented single-burner combustion system.
- Sistema de control: Integrated circuit board with a 7-segment display for simple troubleshooting, built-in disconnect, and status-indicating LED.
- Sistema de ventilador: Quiet operation with a vibration/noise isolated low static pressure axial propeller fan and power venting system.
- Montaje: Retenedores de tuercas roscadas en cuatro puntos de suspensión para montaje en techo o pared (los accesorios de montaje se venden por separado).
- Diseño: Improved cabinet design with a removable front face and a hinged access door panel with a quarter-turn latch.
- Certificaciones: ETL Approved. All UDXC sizes are certified for Commercial/Industrial Use. 30K-120K BTU units also approved for Residential Garages & Workshops.

Figure 1: Key features of the Reznor UDXC-45 Unit Heater, highlighting 83% AFUE Efficiency, Multi-Try Direct Spark Ignition, TCORE2 Heat Exchanger, and Low Noise Operation.

Figure 2: Additional standard features including Status-Indicating LED Light, 7-Segment Display Board for Troubleshooting, 2- and 4-Point Suspension Options, External Gas Connection, and ETL Approval.
Configuración e instalación
Proper installation is crucial for the safe and efficient operation of your Reznor UDXC-45 heater. It is strongly recommended that installation be performed by a certified HVAC professional or gas technician.
Montaje
- The unit is designed for ceiling or wall mounting. It includes threaded-nut retainers at four suspension points.
- Mounting brackets and hardware are sold separately and must be appropriate for the unit's weight and the structural integrity of the mounting surface.
- Ensure the unit is installed in a location that allows for proper air circulation and access for maintenance.
Desfogue
- The unit is compatible with Category 1 double wall B-vent when venting vertically out of a roof.
- Alternatively, it can be vented horizontally through a sidewall using Category 3 single wall vent pipe.
- Toda ventilación debe cumplir con los códigos de construcción locales y las especificaciones del fabricante.

Figura 3: Sobreview of simplified installation features, including updated cabinet structure, hinged access panel, and suspension points for mounting.
Instrucciones de funcionamiento
The Reznor UDXC-45 heater is designed for user-friendly operation. Ensure all gas and electrical connections are securely made and checked by a professional before initial startup.
Poner en marcha el calentador
- Verify that the gas supply valve to the unit is open.
- Ensure the electrical power to the unit is turned on.
- Ajuste el termostato a la temperatura deseada. La unidad se encenderá y apagará automáticamente para mantener la temperatura establecida.
Heating Output Levels
The UDXC-45 features two heating output levels for optimal efficiency:
- Fuego bajo (26,145 BTU): Suitable for milder cool days, providing efficient heating without excessive energy consumption.
- Fuego alto (37,350 BTU): Engages for colder temperatures, ensuring rapid and effective heating of the space.
Operación silenciosa
The unit operates quietly due to its vibration/noise isolated low static pressure axial propeller fan and power venting system. This design minimizes operational noise, making it suitable for environments where sound levels are a consideration.

Figure 4: The Reznor UDXC shop heater's single-burner design offers two BTU outputs for efficient heating in any weather.

Figure 5: The low static pressure axial fan and power venting system ensure optimal air circulation and reduce heat loss.
Video Demonstration: Quiet Operation
This video demonstrates the quiet operation of the Reznor UDXC-45 heater, showcasing the minimal noise produced by the fan during operation. This is particularly useful for environments like workshops or garages where noise levels are a concern.
Video: Hear the quiet operation of the Reznor UDXC-45 heater.
Mantenimiento
Regular maintenance ensures the longevity and optimal performance of your Reznor UDXC-45 heater. It is recommended that all maintenance be performed by a qualified service technician.
- Inspección anual: Have the unit inspected annually by a qualified technician to check for proper operation, gas connections, venting, and overall condition.
- Limpieza: Keep the area around the heater clear of obstructions and debris. Periodically clean the exterior of the unit.
- Intercambiador de calor: The TCORE2 titanium-stabilized aluminized steel heat exchanger is built for durability, but regular checks for any signs of wear or damage are advisable during professional inspections.
- Acceso: The improved cabinet design with a removable front face and a hinged access door panel with a quarter-turn latch simplifies access for maintenance.
Solución de problemas
If your Reznor UDXC-45 heater is not operating as expected, refer to the following general troubleshooting steps. For complex issues, always contact a qualified service technician.
- Sin calefacción/la unidad no arranca:
- Compruebe si la válvula de suministro de gas está abierta.
- Verify that the electrical power to the unit is on.
- Asegúrese de que el termostato esté configurado a una temperatura superior a la temperatura ambiente de la habitación.
- Check the status-indicating LED and the 7-segment display board for error codes, which can assist in diagnosing the issue.
- Ruidos inusuales:
- Asegúrese de que la unidad esté montada de forma segura y libre de vibraciones.
- Contact a technician if unusual noises persist, as it may indicate an issue with the fan or other internal components.
- Calefacción insuficiente:
- Confirm the unit is operating on the appropriate fire level for the ambient temperature.
- Compruebe si hay obstrucciones en las rejillas de entrada o salida de aire.
Presupuesto
| Atributo | Valor |
|---|---|
| Marca | Reznor (1HVAC) |
| Número de modelo | UDXC-45 |
| Tipo de combustible | Gas natural |
| Heat Output (High Fire) | 37,350 unidades térmicas británicas |
| Heat Output (Low Fire) | 26,145 unidades térmicas británicas |
| Eficiencia térmica | 83% |
| Uso en interiores y exteriores | Interior |
| Tipo de montaje | Ceiling Mount / Wall Mount (with separate brackets) |
| Dimensiones del producto | 29.75" de profundidad x 27" de ancho x 13.75" de alto |
| Peso del artículo | 60.9 libras |
| Número de velocidades | 2 |
| Característica especial | Calentamiento rápido, funcionamiento silencioso |

Figure 6: Physical dimensions of the 45,000 BTU Reznor unit heater.
Garantía y soporte
Cobertura de la garantía
El calentador Reznor UDXC-45 viene con la siguiente cobertura de garantía:
- Garantía de 9 año: Conjunto de intercambiador de calor, quemador y caja de recolección de humos.
- Garantía de 4 año: Todos los componentes eléctricos y mecánicos.
To ensure a valid warranty, installation must comply with all local and state codes.
Atención al cliente
For technical assistance, warranty claims, or service inquiries, please contact the manufacturer's authorized service center or your original point of purchase. Always provide your model number (UDXC-45) and serial number when contacting support.