1. Introducción

This manual provides detailed instructions for the EBYTE M31-AXXXA000G 16DI Remote IO Module. This device is designed for industrial automation applications, supporting Modbus TCP and Modbus RTU protocols for data acquisition and control. It features an expandable design, allowing connection of up to 16 IO expansion modules to meet diverse functional requirements.

2. Producto terminadoview

The EBYTE M31-AXXXA000G is a host module in the M31 series, offering 16 digital inputs (DI) and supporting both RS485 and Ethernet (RJ45) communication. It facilitates simultaneous access by up to 5 clients and supports various Modbus function codes (01/02/03/04/05/06/15/16). The module is built for reliability and ease of integration into existing Modbus systems.

Delante y lateral view of the EBYTE M31-AXXXA000G Remote IO Module

Figura 2.1: Frente y lateral view of the EBYTE M31-AXXXA000G Remote IO Module, showing its ports and indicators.

Dimensional drawing of the EBYTE M31-AXXXA000G Remote IO Module

Figure 2.2: Dimensional drawing of the EBYTE M31-AXXXA000G Remote IO Module, indicating its length (110mm), width (40mm), and height (100mm).

Illustration of multiple EBYTE Remote IO Modules

Figure 2.3: Illustration showing multiple EBYTE Remote IO Modules connected, highlighting their modular design and expandability.

EBYTE M31 module's robust design features

Figure 2.4: Image highlighting the module's robust design with anti-fungal, anti-humidity, and anti-salt spray properties, along with a close-up of its circuit board.

3. Configuración

3.1 Montaje

The M31-AXXXA000G module supports installation using positioning holes or guide rails. Ensure a secure mounting location that provides adequate ventilation and protection from environmental factors.

3.2 Cableado y Conexiones

Connect the module to your network via the RJ45 Ethernet port. For RS485 communication, connect the appropriate terminals. Ensure all power connections are correctly made according to the module's specifications.

3.3 Configuración de red

The module supports both DHCP and static IP configurations. Refer to the specific software tools or DIP switch settings for configuring the network parameters to match your system requirements.

3.4 Modbus Address Configuration

Custom Modbus addresses can be set for the module. This can be done either through dedicated configuration software or by using the integrated dial codes (DIP switches) on the device itself.

DIP switches for Modbus address configuration

Figure 3.1: Image depicting the DIP switches on the EBYTE M31 module for quick Modbus address configuration without a host computer.

3.5 Módulos de Expansión

The M31-AXXXA000G host module can connect up to 16 IO expansion modules. Ensure proper physical connection and configuration of each expansion module according to its specific instructions to extend the system's capabilities.

4. Instrucciones de funcionamiento

4.1 Comunicación Modbus

The module supports standard Modbus TCP and Modbus RTU protocols. It can be integrated with various configuration software, PLCs, and HMI touch screens. The device allows simultaneous access by up to 5 clients and supports Modbus function codes 01, 02, 03, 04, 05, 06, 15, and 16.

Modbus system compatibility diagram

Figure 4.1: Diagram showing the EBYTE M31 module's compatibility with HMI touch screens, configuration software, and PLCs within a Modbus system.

4.2 Configuración de la velocidad en baudios

The module supports 8 different baud rate configurations for RS485 communication. Select the appropriate baud rate to match your connected devices for stable data transmission.

4.3 Input Range Configuration

The module's analog input ranges are configurable, making it suitable for 0-20mA and 4-20mA sensors and transmitters.

Configurable input ranges for 0-20mA and 4-20mA sensors

Figure 4.2: Diagram illustrating the configurable input ranges for the module, supporting both 0-20mA and 4-20mA sensors/transmitters.

4.4 Using Upper Computer Software

Utilize the dedicated upper computer software for rapid debugging and parameter configuration of the module. This software provides an interface for monitoring DI status, DO state switching, AI input acquisition, and AO output range settings.

Screenshot of upper computer software for debugging

Figure 4.3: Screenshot of the upper computer software interface, demonstrating its use for rapid debugging and parameter configuration of the EBYTE M31 series modules.

5. Mantenimiento

The EBYTE M31-AXXXA000G module is designed for stable and reliable performance with minimal user maintenance. It features a status diagnosis function that monitors the communication status of IO modules in real-time, aiding in system health checks.

The product undergoes 100% functional and aging tests prior to shipment. Its shell is coated with a conformal coating, providing anti-fungal, anti-humidity, and anti-salt spray properties, ensuring durability in various industrial environments.

Regularly inspect physical connections for any signs of wear or damage. Keep the module free from dust and debris to ensure optimal performance and heat dissipation.

6. Solución de problemas

If you encounter issues with the EBYTE M31-AXXXA000G module, consider the following basic troubleshooting steps:

  • Comprobación de energía: Ensure the module is receiving adequate power and that power connections are secure.
  • Verificación de conexión: Check all Ethernet and RS485 cable connections for proper seating and integrity.
  • Configuración de red: Verify that the IP address, subnet mask, and gateway settings are correct for your network, especially if using a static IP.
  • Dirección Modbus: Confirm that the Modbus address is correctly set, either via DIP switches or software, and does not conflict with other devices on the bus.
  • Velocidad en baudios: For RS485, ensure the baud rate matches that of the connected master device.
  • Indicadores de estado: Observe the module's status indicators (PWR, LINK, STA, etc.) for any error codes or abnormal behavior. Refer to the product documentation for indicator meanings.
  • Diagnóstico de software: Utilize the upper computer software's diagnostic features to monitor communication status and identify potential issues.
  • Módulos de expansión: If using expansion modules, ensure they are correctly connected and configured.

If the problem persists after performing these checks, consult the manufacturer's technical support.

7. Especificaciones

CaracterísticaDescripción
MarcaE-byte
Número de modeloM31-AXXXA000G
TipoRemote IO Host Module
Entradas digitales (ED)16
Entradas analógicas (AI)Not applicable (for this host model)
Salidas digitales (DO)Not applicable (for this host model)
Salidas Analógicas (AO)Not applicable (for this host model)
Interfaz de redEthernet RJ45
Puerto serialRS485
Protocolos admitidosModbus TCP, Modbus RTU
Acceso de clientesUp to 5 simultaneous clients
Códigos de función Modbus01, 02, 03, 04, 05, 06, 15, 16
Baud Rate Configurations8 opciones
Configuración de IPDHCP, IP estática
Capacidad de expansiónSupports up to 16 IO expansion modules
Protección ambientalAnti-Fungal, Anti-Humidity, Anti-Salt Spray
Comparison table of M31 series modules

Figure 7.1: Table comparing specifications and parameters across various M31 series host and expansion modules, detailing digital inputs, analog inputs, digital outputs, analog outputs, network, and serial port options.

8. Garantía y soporte

For warranty information, please refer to the terms and conditions provided by the seller or contact EBYTE directly. Technical support and further assistance can be obtained through the official EBYTE channels or your product distributor.

Documentos relacionados - M31-AXXXA000G

Preview Manual del usuario del host de E/S distribuidas de alto rendimiento de la serie EBYTE M31-U
Manual de usuario del host de E/S distribuidas de alto rendimiento de la serie EBYTE M31-U, que detalla sus características, especificaciones, configuración y configuración para la adquisición y el control de datos industriales. Compatible con los protocolos Modbus TCP/RTU.
Preview EBYTE M31 Series Distributed IO Host User Manual
User manual for the EBYTE M31 Series Distributed IO Host, detailing its features, connectivity, configuration, and operation for industrial automation and IoT applications. Supports Modbus TCP/RTU and IO expansion.
Preview M31-U 系列高性能分布式 IO 主机用户手册
用户手册详细介绍了 EBYTE M31-U 系列高性能分布式 IO主机,包括产品概述、功能特点、技术指标、连接指南、参数配置和故障排除。适用于工业自动化数据采集与控制。
Preview Manual del usuario del módem inalámbrico EBYTE ME31-AXAX4040 | Módulo de red de E/S
Manual de usuario completo del módulo de red de E/S EBYTE ME31-AXAX4040, que detalla sus características, especificaciones, conexión, configuración y funcionamiento con protocolos Modbus TCP/RTU.
Preview EBYTE MA01/MA02-AXCX4040 无线调制解调器用户手册
EBYTE MA01/MA02-AXCX4040用户手册提供了关于这款4路数字输入(DI)和4路数字输出( DO)的串口E/S联网模块的详细信息。该模块支持Modbus RTU协议,适用于工业自动化、远程数据采集和控制应用。
Preview Manual del usuario del módulo de adquisición de datos E820-AIO | Ebyte
Manual de usuario completo del módulo de adquisición de datos Ebyte E820-AIO. Conozca sus características, parámetros eléctricos, definiciones de pines, métodos de conexión, registros ModBus y formatos de instrucciones.