First Alert SMCO100V-AC

First Alert SMCO100V-AC Combination Smoke and Carbon Monoxide Alarm

Manual de usuario

1. Introducción

This manual provides essential information for the installation, operation, and maintenance of your First Alert SMCO100V-AC Combination Smoke and Carbon Monoxide Alarm. This device is designed to provide early warning of both smoke and carbon monoxide presence in your home, enhancing safety through advanced detection technology, voice alerts, and hardwire interconnectivity.

Please read this manual thoroughly before installation and retain it for future reference. Proper installation and regular maintenance are crucial for the effective operation of this safety device.

2. Información importante de seguridad

ADVERTENCIA: This unit is designed to detect smoke and carbon monoxide. It is not designed to detect fire, heat, or other gases. It will not prevent a fire or carbon monoxide poisoning. For maximum protection, ensure proper installation and regular testing.

  • Never ignore any alarm. Responding to an alarm can save lives.
  • Do not paint the alarm. Paint can clog the sensing chambers and prevent the unit from operating correctly.
  • Do not remove the battery unless replacing it. The battery provides backup power during outages.
  • Pruebe la alarma semanalmente para garantizar su correcto funcionamiento.
  • Ensure all household members know the alarm sounds and how to respond.

3. Características del producto

The First Alert SMCO100V-AC alarm incorporates several features designed for enhanced home safety:

  • Precision Detection Technology: Advanced sensing technology complies with new industry standards, reducing nuisance alarms from cooking while providing early warning for actual fire emergencies.
  • Alertas de voz y ubicación: When an alarm is triggered, the unit provides clear voice announcements indicating the type of danger (smoke or carbon monoxide) and its location, aiding in safe escape.
  • Interconnect Hardwire Capability: Allows multiple compatible alarms to be wired together. If one interconnected alarm sounds, all connected alarms will sound, providing early warning throughout the home.
  • Copia de seguridad de la batería: A built-in battery provides continuous protection during power outages, ensuring the alarm remains operational even when household electricity is interrupted.
  • Enchufe de conexión rápida: Facilitates easy installation without the need for extensive rewiring, simplifying the setup process.
First Alert SMCO100V-AC alarm with Voice & Location Alerts graphic

Image: The First Alert SMCO100V-AC alarm highlighting its Voice & Location Alerts feature, which verbally identifies the type and location of danger.

Precision Detection Advanced Sensing Technology graphic

Image: Graphic illustrating Precision Detection Advanced Sensing Technology, emphasizing early warning and reduced nuisance alarms.

4. Configuración e instalación

4.1 Contenido del paquete

Antes de comenzar la instalación, verifique que su paquete contenga los siguientes elementos:

  • First Alert SMCO100V-AC Combination Smoke and Carbon Monoxide Alarm
  • Soporte de montaje
  • AA Batteries (for backup)
  • Easy Adapter Plug / Wiring Harness
First Alert SMCO100V-AC alarm with battery compartment open, wiring harness, and mounting hardware

Image: Components of the First Alert SMCO100V-AC alarm, including the main unit with its battery compartment open, the wiring harness, and mounting screws.

4.2 Ubicación recomendada

For optimal protection, install alarms on every level of your home and in every bedroom. Consider placing alarms in hallways leading to bedrooms and in living areas. Avoid placing alarms in kitchens directly above cooking appliances or in bathrooms where steam can cause nuisance alarms.

Diagram showing recommended placement of smoke and CO alarms in a house

Image: A diagram illustrating recommended locations for smoke alarms, carbon monoxide alarms, and fire extinguishers within a typical home layout.

4.3 pasos de instalación

  1. Apagar la energía: Before beginning any electrical work, ensure the power to the circuit where you will install the alarm is turned off at the main fuse or circuit breaker box.
  2. Instalación del soporte de montaje: Secure the mounting bracket to the ceiling or wall using the provided screws. If replacing an existing alarm, you may be able to use the existing bracket if compatible, but it is recommended to use the new one.
  3. Conexión de cableado: Connect the alarm's wiring harness to your household electrical wiring. The Quick Connect Plug simplifies this process. Ensure proper polarity (black to black, white to white, and red/orange to red/orange for interconnect).
  4. Instalación de la batería: Open the battery compartment and insert the AA batteries provided, observing the correct polarity. The battery provides backup power.
  5. Fije la alarma al soporte: Align the alarm with the mounting bracket and twist clockwise until it locks securely into place.
  6. Restaurar energía: Turn the power back on at the main fuse or circuit breaker box.
  7. Pruebe la alarma: Press and hold the 'Test/Silence' button for a few seconds until the alarm sounds. This confirms the unit is receiving power and functioning correctly.
First Alert SMCO100V-AC alarm installed on a ceiling, showing its wired connection

Image: A First Alert SMCO100V-AC alarm installed on a ceiling, demonstrating its hardwired setup.

5. Instrucciones de funcionamiento

5.1 Operación normal

During normal operation, the green LED indicator will flash approximately once every minute, indicating that the alarm is receiving power and functioning correctly. The alarm will remain silent unless smoke or carbon monoxide is detected, or the test button is pressed.

5.2 Condiciones de alarma

  • Alarma de humo: If smoke is detected, the alarm will sound a loud, intermittent horn pattern (three beeps, pause, three beeps). The voice alert will announce "FIRE! FIRE!" and indicate the location if programmed. The red LED will flash rapidly.
  • Alarma de monóxido de carbono (CO): If carbon monoxide is detected, the alarm will sound four quick beeps, pause, four quick beeps. The voice alert will announce "WARNING! CARBON MONOXIDE!" and indicate the location if programmed. The red LED will flash rapidly.
  • Advertencia de batería baja: The alarm will chirp approximately once every minute, accompanied by a voice announcement "LOW BATTERY." This indicates the battery backup needs replacement.
  • Malfunction/End-of-Life Warning: The alarm will chirp twice every 30 seconds, accompanied by a voice announcement "MALFUNCTION" or "REPLACE ALARM." This indicates a fault with the unit or that it has reached the end of its operational life and needs replacement.

5.3 Botón de prueba/silencio

The large 'Test/Silence' button on the front of the alarm serves two primary functions:

  • Pruebas: Press and hold the button for a few seconds to test the alarm's electronic circuitry, horn, and battery. The alarm will sound, and voice alerts will activate. Test weekly.
  • Silenciamiento: In the event of a nuisance alarm (e.g., from cooking smoke), pressing the button will temporarily silence the alarm for several minutes. The alarm will automatically reset after the silence period if the smoke or CO concentration has cleared. If the danger persists, the alarm will reactivate.

6. Mantenimiento

6.1 Pruebas periódicas

Test your alarm weekly by pressing and holding the 'Test/Silence' button until the alarm sounds. This ensures the unit is functioning correctly.

6.2 Reemplazo de batería

When the alarm chirps once every minute and announces "LOW BATTERY," it is time to replace the backup batteries. Use only the specified AA batteries. To replace:

  1. Gire la alarma en sentido antihorario para quitarla del soporte de montaje.
  2. Abra el compartimento de la batería.
  3. Retire las baterías viejas y deséchelas adecuadamente.
  4. Inserte pilas AA nuevas, asegurándose de la polaridad correcta.
  5. Cierre el compartimiento de la batería y vuelva a colocar la alarma en el soporte de montaje girándola en el sentido de las agujas del reloj.
  6. Pruebe la alarma después de reemplazar la batería.

6.3 Limpieza de su alarma

Clean your alarm at least once a month to remove dust and debris. Use a soft brush attachment on your vacuum cleaner to gently vacuum the alarm's cover and vents. Do not use cleaning solvents or spray cleaners directly on the alarm.

6.4 Alarm Replacement

Smoke and carbon monoxide alarms have a limited lifespan. This alarm should be replaced at least every 10 years from the date of manufacture. The alarm will indicate an end-of-life warning with specific chirps and voice announcements. Refer to the date code on the back of the alarm for the manufacture date.

7. Solución de problemas

If your alarm is not functioning as expected, refer to the table below for common issues and solutions.

ProblemaPosible causaSolución
Alarm chirps once every minute with "LOW BATTERY" voice.Backup batteries are low.Replace the AA batteries immediately.
Alarm chirps twice every 30 seconds with "MALFUNCTION" or "REPLACE ALARM" voice.Unit malfunction or end-of-life.Replace the entire alarm unit.
Alarm sounds frequently without apparent smoke or CO.Nuisance alarm (e.g., cooking smoke, steam, dust).Press the 'Silence' button. Clean the alarm. Relocate if consistently triggered by normal activities.
La alarma no suena durante la prueba.Sin energía, baterías agotadas o mal funcionamiento de la unidad.Check household power. Replace batteries. If still no sound, replace the unit.
No todas las alarmas interconectadas suenan.Wiring issue or incompatible units.Verify interconnect wiring. Ensure all interconnected units are compatible models. Consult an electrician if necessary.

8. Especificaciones

  • Modelo: SMCO100V-CA
  • Marca: Primera alerta
  • Fuente de energía: Eléctrico con cable y batería de respaldo
  • Tipo de batería: AA Alkaline (included)
  • Tipo de alarma: Combination Smoke and Carbon Monoxide
  • Dimensiones: 5.1" de profundidad x 5.1" de ancho x 2.4" de alto
  • Peso del artículo: 11.2 onzas
  • Color: Blanco
  • Interconexión: Interconexión cableada
  • Fabricante: Residencia
  • Código postal: 029054022097

9. Información de garantía

This First Alert SMCO100V-AC Combination Smoke and Carbon Monoxide Alarm comes with a Garantía limitada de años 10. For detailed terms and conditions, please refer to the warranty documentation included with your product or visit the official First Alert websitio.

10. Atención al cliente

If you have any questions regarding the installation, operation, or maintenance of your First Alert alarm, or if you require technical assistance, please contact First Alert customer support. Contact information can typically be found on the product packaging or the official First Alert websitio.

Websitio: www.firstalert.com