Introducción
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 5 Ton 16 SEER2 High Efficiency Heat Pump Condenser. Please read all instructions carefully before installation and use. Professional installation by a certified technician is required to ensure proper function and warranty validity.

Figure 1: ACiQ 5 Ton 16 SEER2 Heat Pump Condenser outdoor unit.
Configuración e instalación
Installation of the ACiQ Heat Pump Condenser requires specialized knowledge and tools. It must be performed by a qualified HVAC technician. Key considerations include:
- Ubicación de la unidad exterior: Ensure adequate clearance around the unit for proper airflow and maintenance. The compact design allows for a smaller footprint compared to traditional units.
- Refrigerante: This unit uses R-454B refrigerant. Proper handling and charging procedures must be followed.
- Unidad de tratamiento de aire: The system supports a multi-positional air handler unit, allowing for upflow, downflow, or horizontal installation to suit various ducting designs.
- Conexiones eléctricas: All electrical wiring must comply with local codes and standards.

Figure 2: Outdoor unit size comparison, highlighting the ACiQ's smaller footprint.

Figure 3: Multi-positional air handler unit for flexible installation (upflow, downflow, horizontal).
Vídeo 1: Terminadoview of ACiQ HPD/EHPD Condenser and System features, including installation flexibility.
Instrucciones de funcionamiento
Your ACiQ Heat Pump Condenser is designed for high efficiency and reliable performance across a wide range of temperatures. It features advanced inverter technology for precise temperature control and reduced energy consumption.
- Rango de temperatura: This unit delivers reliable warmth down to -22°F and provides effective cooling up to 122°F.
- Funcionamiento silencioso: The inverter technology ensures whisper-quiet operation, minimizing noise disruptions.
- Control inteligente Compatible with Wi-Fi smart thermostats for convenient control and optimization of your home's climate.

Figure 4: The ACiQ unit's capability to operate in extreme cold (down to -22°F) and extreme heat (up to 122°F).

Figure 5: The ACiQ heat pump operates quietly, ensuring no interruptions.
Video 2: ACiQ HPD System overview, demonstrating its performance and features.
Mantenimiento
Regular maintenance is crucial for the longevity and efficiency of your ACiQ Heat Pump Condenser. While some tasks can be performed by the homeowner, annual professional servicing is highly recommended.
- Función de autolimpieza: The unit features a self-cleaning mechanism that automatically clears debris, reducing the need for frequent manual cleaning.
- Reemplazo del filtro: Regularly check and replace air filters in your indoor air handler unit as per manufacturer recommendations to maintain optimal airflow and air quality.
- Inspección profesional: Schedule annual inspections and tune-ups with a certified HVAC technician to ensure all components are functioning correctly and to prevent potential issues.

Figure 6: The ACiQ unit's self-cleaning feature automatically clears debris.
Solución de problemas
If you experience issues with your ACiQ Heat Pump Condenser, consider the following basic troubleshooting steps. For complex problems, always contact a qualified technician.
- Sin energía: Verifique el disyuntor y asegúrese de que la unidad esté conectada correctamente a la fuente de alimentación.
- Calefacción/refrigeración insuficiente: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is free of obstructions.
- Ruidos inusuales: Minor noises are normal during operation. However, loud or persistent unusual noises may indicate a problem and require professional inspection.
- Códigos de error: If your thermostat or unit displays an error code, consult your technician or the full product manual for specific meanings and solutions.
Do not attempt to repair internal components yourself. This can void your warranty and pose safety risks.
Presupuesto
| Característica | Detalle |
|---|---|
| Nombre de marca | ACiQ |
| Número de modelo | ACiQ-60-HPD |
| Dimensiones del producto | 16.34" de profundidad x 37.48" de ancho x 52.48" de alto |
| Eficiencia (SEER2) | 16 SEER2 (18.0 SEER) |
| Capacidad | 5 Ton (60,000 BTU) / 4.69 Tons |
| Nivel de ruido | 56 decibelios |
| Tipo de instalación | Sistema dividido |
| Factor de forma | Sistema dividido |
| Características especiales | Inverter Condenser, Learning System |
| Refrigerante | R-454B |
| Fuente de poder | Eléctrico con cable |

Figure 7: Cooling Capacity performance at various ambient temperatures.

Figure 8: Heating Capacity performance at various ambient temperatures.
Información de garantía
Your ACiQ Heat Pump Condenser comes with a comprehensive warranty:
- Garantía de piezas de 7 años
- Garantía del compresor de 12 años
These warranty terms are valid when the unit is installed by a certified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records for warranty claims.

Figure 9: Warranty coverage terms for ACiQ products.
Apoyo
For technical assistance, service, or any questions regarding your ACiQ Heat Pump Condenser, please contact your certified ACiQ dealer or the manufacturer's support team. Our dedicated support team is available to provide assistance.
Visit the official ACiQ webSitio para recursos adicionales, preguntas frecuentes e información de contacto: ACiQ Store