ACiQ RXNG09AXVJU / FTXNG09AXVJU

Manual del usuario del sistema de aire acondicionado/calefacción minisplit Goodman Serie E

Model: RXNG09AXVJU / FTXNG09AXVJU | Brand: ACiQ

Introducción

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Goodman Mini-Split AC/Heating System E-Series. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed to provide efficient heating and cooling for residential and light commercial applications.

Configuración e instalación

The Goodman Mini-Split AC/Heating System E-Series includes an indoor wall-mounted air handler unit, an outdoor mini-split heat pump condenser, and a comprehensive installation kit. Professional installation is recommended for optimal performance and safety.

Componentes incluidos

Goodman Mini-Split AC/Heating System E-Series with all components

Figura 1: Sobreview of the Goodman Mini-Split AC/Heating System E-Series and its included components, showing the indoor unit, outdoor unit, remote control, and installation kit elements.

Consideraciones de instalación

Ensure the installation area for both indoor and outdoor units meets the required clearances for proper airflow and maintenance. The system operates on 208/230V, 1 Phase, 60Hz power. The 0.75-ton unit is designed to efficiently heat and cool areas up to 400 square feet.

ACiQ Mini Split Installation Kit components

Figura 2: detallada view of the ACiQ Mini Split Installation Kit, including line sets, control wire, drain tube, wall mount bracket, and line cover guards.

Instrucciones de funcionamiento

Your Goodman E-Series Mini-Split system offers various modes and features for optimal comfort and energy efficiency.

Modos básicos de funcionamiento

Características y controles clave

Goodman E-Series Mini-Split features list

Figure 3: Illustration of the key features of the Goodman E-Series Mini-Split system, including remote control, auto-restart, self-diagnosis, and various operational modes.

Mantenimiento

Regular maintenance ensures the longevity and efficient operation of your mini-split system. Always disconnect power to the unit before performing any maintenance.

Limpieza de filtros

The system is equipped with a Catechin Air Quality Filter System and a Titanium Apatite Deodorising Filter. These filters should be cleaned regularly, typically every 2-4 weeks depending on usage and air quality. Refer to the specific instructions in your full product manual for filter removal and cleaning procedures. Generally, filters can be gently vacuumed or washed with lukewarm water and mild detergent, then air-dried completely before reinstallation.

Drain Pan Maintenance

The indoor unit features a removable dirt-water drain pan. Periodically inspect and clean the drain pan to prevent mold growth and blockages, which can lead to water leaks. Ensure the drain tube is clear and free of obstructions.

Limpieza de la unidad

The indoor unit has a wipe-clean flat panel. Use a soft, damp cloth to clean the exterior surfaces. Do not use harsh chemicals or abrasive cleaners. For the outdoor unit, ensure the coils are free of debris and obstructions. The outdoor unit also features anti-corrosion treatment for enhanced durability.

Solución de problemas

Before contacting customer support, please refer to the following common issues and solutions. The self-diagnosis feature with a digital display can provide initial indications of problems.

ProblemaPosible causaSolución
La unidad no se enciendeNo power, remote control batteries low, unit switch off.Check power supply, replace remote batteries, ensure indoor unit ON/OFF switch is engaged.
Calefacción/refrigeración insuficienteDirty air filters, blocked outdoor unit, incorrect mode/temperature setting, refrigerant leak.Limpie los filtros, elimine las obstrucciones de la unidad exterior, verifique la configuración y comuníquese con un profesional para verificar el refrigerante.
Ruido inusualPiezas sueltas, obstrucción del ventilador, ruido del flujo de refrigerante (normal).Inspect for loose parts or obstructions. If noise persists or is abnormal, contact service.
Fuga de agua de la unidad interiorClogged drain pan/tube, improper installation.Clean drain pan and tube. If issue persists, professional inspection is required.
La pantalla digital muestra el código de errorFallo interno del sistema.Note the error code and consult the full product manual or contact customer support for specific guidance.

For issues not listed or if troubleshooting steps do not resolve the problem, please contact a qualified HVAC technician or ACiQ customer support.

Presupuesto

Detailed technical specifications for the Goodman Mini-Split AC/Heating System E-Series (0.75 Ton, 9000 BTU).

AtributoValor
Nombre de marcaACiQ
Información del modeloRXNG09AXVJU / FTXNG09AXVJU
BTU Capacity (Cooling)9,000 BTU (0.75 toneladas)
BTU Capacity (Heating)4,400 BTU – 13,000 BTU
Eficiencia SEER218 VIDENTE2
Volumentage208/230 Volts, 1 Phase, 60Hz
Nivel de ruido (unidad exterior)56 dB
Tipo de instalaciónSistema dividido
Factor de formaMini-Split
RefrigeranteR410A
Área de cobertura recomendadaHasta 400 pies cuadrados
Goodman Mini-Split AC/Heating System dimensions and specifications

Figure 4: Dimensional specifications and performance ratings for the Goodman Mini-Split AC/Heating System, including BTU, square footage coverage, and noise levels.

Garantía y soporte

For warranty information, please refer to the warranty card included with your product or visit the official ACiQ website. Warranty terms typically cover manufacturing defects and vary by component.

For technical support, service requests, or to inquire about replacement parts, please contact ACiQ customer service. Have your model number (RXNG09AXVJU / FTXNG09AXVJU) and purchase date ready when contacting support.

Recursos en línea: For additional resources, FAQs, and product registration, visit the Tienda ACiQ en Amazon.

Documentos relacionados - RXNG09AXVJU / FTXNG09AXVJU

Preview Manual de instalación y del propietario del minisplit monozona estándar ACiQ
Guía completa para la instalación y el funcionamiento de sistemas de aire acondicionado minisplit monozona ACiQ Standard. Abarca precauciones de seguridad, especificaciones de la unidad, procedimientos de instalación, mantenimiento y resolución de problemas.
Preview Sistemas de calefacción de una sola zona ACiQ 9K-24K: Manual de instalación y del usuario
Manual de instalación y manejo de los sistemas de calefacción monozona ACiQ 9K-24K Standard Heat. Esta guía detalla la instalación, el funcionamiento, la seguridad y el mantenimiento de los aires acondicionados ACiQ, incluyendo las especificaciones del modelo e información sobre el refrigerante R454B.
Preview Guía de solución de problemas del condensador multizona y manejador de aire de pared ACiQ R32
This troubleshooting guide provides detailed steps and solutions for common faults and errors encountered with ACiQ R32 Multi-Zone Condenser and Wall Mounted Air Handler systems, including sensor faults, communication errors, and component issues.
Preview Sistemas de calefacción de una sola zona ACiQ 9K-24K: Manual de instalación y del usuario
Manual completo de instalación y del propietario para sistemas de calor estándar de zona única ACiQ 9K-24K, que cubre la configuración, el funcionamiento, el mantenimiento y la resolución de problemas de varios modelos ACiQ.
Preview Manual de instalación y del propietario del manejador de aire mural ACiQ y del condensador monozona para calor extremo
Este manual proporciona instrucciones detalladas de instalación, funcionamiento y seguridad para los manejadores de aire de pared ACiQ y los condensadores de zona única de calor extremo, que cubren los modelos ACIQ-06W-HH-MD a ACIQ-24ZPL-HP230C.
Preview Manual técnico y de servicio del condensador multizona y manejador de aire de pared ACiQ R32
Comprehensive service and technical manual for ACiQ R32 Multi-Zone Condenser and Wall Mounted Air Handler units. This guide provides detailed information on installation, operation, troubleshooting, and maintenance for models ACiQ-09W-E-M, ACiQ-12W-E-M, ACiQ-18W-E-M, ACiQ-18Z-E-M2, and ACiQ-24Z-E-M3.