This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Goodman Mini-Split AC/Heating System E-Series. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed to provide efficient heating and cooling for residential and light commercial applications.
Configuración e instalación
The Goodman Mini-Split AC/Heating System E-Series includes an indoor wall-mounted air handler unit, an outdoor mini-split heat pump condenser, and a comprehensive installation kit. Professional installation is recommended for optimal performance and safety.
Componentes incluidos
- Unidad de tratamiento de aire de pared para interiores
- Outdoor Mini Split Heat Pump Condenser
- Line Set (30-foot length, 1/4 x 3/8 copper lines)
- Cable de control
- Wall Mount Bracket (18 1/4" Length)
- Line Cover Guards
- Drain Tube (20-foot)
- Control remoto inalámbrico

Figura 1: Sobreview of the Goodman Mini-Split AC/Heating System E-Series and its included components, showing the indoor unit, outdoor unit, remote control, and installation kit elements.
Consideraciones de instalación
Ensure the installation area for both indoor and outdoor units meets the required clearances for proper airflow and maintenance. The system operates on 208/230V, 1 Phase, 60Hz power. The 0.75-ton unit is designed to efficiently heat and cool areas up to 400 square feet.

Figura 2: detallada view of the ACiQ Mini Split Installation Kit, including line sets, control wire, drain tube, wall mount bracket, and line cover guards.
Instrucciones de funcionamiento
Your Goodman E-Series Mini-Split system offers various modes and features for optimal comfort and energy efficiency.
Modos básicos de funcionamiento
- Modo de enfriamiento: Reduce la temperatura ambiente al valor deseado.
- Modo de calefacción: Aumenta la temperatura ambiente al valor deseado.
- Modo de ventilador: Hace circular el aire sin calentar ni enfriar.
- Modo seco (deshumidificación): Reduce la humedad en la habitación.
- Modo automático: Automatically selects heating or cooling based on the set temperature and current room temperature.
Características y controles clave
- Wireless Backlight Remote Control: Permite un ajuste cómodo de la configuración desde cualquier lugar de la habitación.
- Auto-Restart After Power Failure: La unidad reanudará automáticamente el funcionamiento con la configuración anterior después de un corte de energía.tage.
- Self-Diagnosis with Digital Display: Provides error codes on the digital display for easier troubleshooting.
- Adjustable LED Display ON/OFF: Control the visibility of the unit's LED display.
- Power Saving Sleep Mode Set-up: Optimiza la temperatura y la velocidad del ventilador para un sueño confortable mientras conserva energía.

Figure 3: Illustration of the key features of the Goodman E-Series Mini-Split system, including remote control, auto-restart, self-diagnosis, and various operational modes.
Mantenimiento
Regular maintenance ensures the longevity and efficient operation of your mini-split system. Always disconnect power to the unit before performing any maintenance.
Limpieza de filtros
The system is equipped with a Catechin Air Quality Filter System and a Titanium Apatite Deodorising Filter. These filters should be cleaned regularly, typically every 2-4 weeks depending on usage and air quality. Refer to the specific instructions in your full product manual for filter removal and cleaning procedures. Generally, filters can be gently vacuumed or washed with lukewarm water and mild detergent, then air-dried completely before reinstallation.
Drain Pan Maintenance
The indoor unit features a removable dirt-water drain pan. Periodically inspect and clean the drain pan to prevent mold growth and blockages, which can lead to water leaks. Ensure the drain tube is clear and free of obstructions.
Limpieza de la unidad
The indoor unit has a wipe-clean flat panel. Use a soft, damp cloth to clean the exterior surfaces. Do not use harsh chemicals or abrasive cleaners. For the outdoor unit, ensure the coils are free of debris and obstructions. The outdoor unit also features anti-corrosion treatment for enhanced durability.
Solución de problemas
Before contacting customer support, please refer to the following common issues and solutions. The self-diagnosis feature with a digital display can provide initial indications of problems.
| Problema | Posible causa | Solución |
|---|---|---|
| La unidad no se enciende | No power, remote control batteries low, unit switch off. | Check power supply, replace remote batteries, ensure indoor unit ON/OFF switch is engaged. |
| Calefacción/refrigeración insuficiente | Dirty air filters, blocked outdoor unit, incorrect mode/temperature setting, refrigerant leak. | Limpie los filtros, elimine las obstrucciones de la unidad exterior, verifique la configuración y comuníquese con un profesional para verificar el refrigerante. |
| Ruido inusual | Piezas sueltas, obstrucción del ventilador, ruido del flujo de refrigerante (normal). | Inspect for loose parts or obstructions. If noise persists or is abnormal, contact service. |
| Fuga de agua de la unidad interior | Clogged drain pan/tube, improper installation. | Clean drain pan and tube. If issue persists, professional inspection is required. |
| La pantalla digital muestra el código de error | Fallo interno del sistema. | Note the error code and consult the full product manual or contact customer support for specific guidance. |
For issues not listed or if troubleshooting steps do not resolve the problem, please contact a qualified HVAC technician or ACiQ customer support.
Presupuesto
Detailed technical specifications for the Goodman Mini-Split AC/Heating System E-Series (0.75 Ton, 9000 BTU).
| Atributo | Valor |
|---|---|
| Nombre de marca | ACiQ |
| Información del modelo | RXNG09AXVJU / FTXNG09AXVJU |
| BTU Capacity (Cooling) | 9,000 BTU (0.75 toneladas) |
| BTU Capacity (Heating) | 4,400 BTU – 13,000 BTU |
| Eficiencia SEER2 | 18 VIDENTE2 |
| Volumentage | 208/230 Volts, 1 Phase, 60Hz |
| Nivel de ruido (unidad exterior) | 56 dB |
| Tipo de instalación | Sistema dividido |
| Factor de forma | Mini-Split |
| Refrigerante | R410A |
| Área de cobertura recomendada | Hasta 400 pies cuadrados |

Figure 4: Dimensional specifications and performance ratings for the Goodman Mini-Split AC/Heating System, including BTU, square footage coverage, and noise levels.
Garantía y soporte
For warranty information, please refer to the warranty card included with your product or visit the official ACiQ website. Warranty terms typically cover manufacturing defects and vary by component.
For technical support, service requests, or to inquire about replacement parts, please contact ACiQ customer service. Have your model number (RXNG09AXVJU / FTXNG09AXVJU) and purchase date ready when contacting support.
Recursos en línea: For additional resources, FAQs, and product registration, visit the Tienda ACiQ en Amazon.