PULACO PL-POND

PULACO 130W 3700GPH Amphibious Water Pump Instruction Manual

Model: PL-POND

1. Introducción

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your PULACO 130W 3700GPH Amphibious Water Pump. This versatile pump is designed for use in various water environments, including garden ponds, aquariums, and fountains. It features a variable frequency motor for energy efficiency and quiet operation.

Please read this manual thoroughly before using the pump and retain it for future reference.

2. Características del producto

3. Contenido del paquete

Verifique que todos los artículos estén presentes y sin daños al abrir el paquete:

PULACO Water Pump and included accessories

Image: Contents of the PULACO Water Pump package, including the pump, power cord, suction cups, various nozzles, sealing rings, and PVC connectors.

4. Instrucciones de seguridad

ADVERTENCIA: No seguir estas instrucciones de seguridad puede provocar descargas eléctricas, incendios o lesiones graves.

5. Configuración e instalación

The PULACO water pump can be installed in two modes: Submersible Mode or Ground Mode.

5.1. Componente terminadoview

Pump Disassembly Diagram showing handle, shaft, water outlet, water inlet, pump body, and filter cover

Image: Diagram illustrating the main components of the pump, including the handle, shaft, water outlet, water inlet, pump body, and detachable filter cover.

5.2. Nozzle and Connector Attachment

Select the appropriate nozzle (30mm or 35mm) or 1.5-inch PVC connector based on your tubing requirements. Ensure sealing rings are properly seated for a watertight connection. Use the adjustable fasten steel rings to secure soft tube connections.

Pump dimensions and various nozzle and PVC connector sizes

Image: The pump with its dimensions (10 inches long, 4.3 inches wide) and examples of 1.2-inch, 1.4-inch nozzles, and 1.5-inch PVC connectors.

5.3. Adjustable Outlet Direction

The pump's outlet direction can be adjusted to suit your setup, offering flexibility for connection angles (0°, 90°, 180°).

Diagram showing adjustable outlet direction of the pump at 0, 90, and 180 degrees

Image: Illustration of the pump's adjustable water outlet, demonstrating how it can be rotated to different angles for convenient connection.

5.4. Installation Modes

Diagrams showing submersible and ground mode installation for the water pump

Image: Visual guide for installing the pump in Submersible Mode (fully submerged) and Ground Mode (external, with the pump below the water line).

Submersible Mode:

Install the pump completely underwater. The IPX8 submersible design ensures safe operation. Use the suction cups to secure the pump to a clean, flat surface at the bottom of your pond or aquarium.

Ground Mode (External Installation):

For ground mode, install the pump lower than the pool/tank water line to ensure water flows to the inlet automatically. This pump does not have a self-priming function. Seal the 1.5-inch PVC connectors with PTFE tape for a secure, leak-free connection. Install the pump in a cool place to prevent overheating. Do not continuously run the pump for over 24 hours in Ground Mode, especially in high-temperature environments, to ensure normal service life.

6. Instrucciones de funcionamiento

Once installed and connected, the pump operates simply:

  1. Ensure all connections are secure and the pump is correctly positioned for your chosen mode (submersible or ground).
  2. Plug the power cord into a suitable, grounded electrical outlet. The pump will start working immediately.
  3. Para detener la bomba, desconecte el cable de alimentación del tomacorriente.

For optimal performance in Ground Mode, ensure the pump is always below the water level of the source to facilitate water intake.

Collage of pump applications in a garden pond, aquarium, aquaculture tank, and small pool

Imagen: Examples of the PULACO water pump in various applications, including a garden pond with a waterfall, an aquarium, an aquaculture setup, and a small pool.

7. Mantenimiento

Regular cleaning and maintenance are crucial for ensuring the pump's standard performance and extending its lifespan.

  1. Desconectar la energía: Desenchufe siempre la bomba de la fuente de alimentación antes de cualquier mantenimiento.
  2. Retire la cubierta del filtro: Detach the filter cover from the pump body.
  3. Impulsor de acceso: Carefully remove the impeller. Refer to the 'Pump Disassembly Diagram' in Section 5.1 for guidance.
  4. Componentes limpios: Use a small brush or a stream of water to remove any accumulated debris, algae, or mineral deposits from the filter cover, impeller, and pump housing.
  5. Inspeccionar si hay daños: Check the impeller and ceramic axis for any signs of wear or damage. Replace if necessary.
  6. Volver a montar: Reassemble the pump components in reverse order, ensuring all parts are securely fitted.
  7. Limpieza regular: Clean the pump regularly, especially if operating in environments with high debris or algae content.

8. Solución de problemas

If you encounter issues with your PULACO water pump, refer to the following common problems and solutions:

ProblemaPosible causaSolución
La bomba no arrancaSin suministro de energía
Impeller jammed by debris
Fallo del motor
Verifique la conexión eléctrica y el tomacorriente.
Disconnect power and clean impeller/housing
Contactar con atención al cliente
Caudal reducidoClogged filter or impeller
Tubos doblados o bloqueados
Insufficient water level (Ground Mode)
Clean filter and impeller
Inspeccionar y limpiar los tubos
Ensure pump is below water line
Ruido o vibración excesivosEscombros en el impulsor
Pump not securely placed
Se está secando
Disconnect power and clean impeller
Secure pump with suction cups or stable base
Ensure pump is submerged or has water supply
La bomba se detiene inesperadamenteOverheating (thermal protection activated)
Interrupción de energía
Impulsor atascado
Unplug, let cool, then restart; ensure proper ventilation (Ground Mode)
Comprobar la fuente de alimentación
Disconnect power and clean impeller

If the problem persists after attempting these solutions, please contact PULACO customer support.

9. Especificaciones

ParámetroValor
Número de modeloPL-POND
Volumentage110-120 V/60 Hz
Fuerza130 W
Caudal máximo3700 GPH (galones por hora)
Elevación máxima24 pies (FT)
Longitud del cable de alimentación24.75 pies (FT)
Peso del artículo6.59 libras
Dimensiones del paquete14.5 x 9 x 9 pulgadas
EstiloSumergible
Clasificación de impermeabilidadIPX8

10. Garantía y soporte

For warranty information or technical support, please contact PULACO customer service directly. Keep your purchase receipt as proof of purchase.

PULACO Customer Service: Refer to the contact information provided with your product packaging or visit the official PULACO websitio.

Documentos relacionados - PL-POND

Preview Manual del usuario del skimmer y fuente flotante para estanques SunSun CSP-250
Comprehensive user manual for the SunSun CSP-250 floating pond skimmer and fountain. Learn about installation, operation, features, maintenance, and safety instructions for this versatile garden pond device. Includes technical specifications and troubleshooting.
Preview Kit para estanques Smartpond Ultimate 91340 - Manual de instalación y funcionamiento
Guía completa del Kit para Estanque Smartpond Ultimate (Modelo 91340), que abarca el contenido del paquete, la preparación, las instrucciones de funcionamiento, el mantenimiento, la resolución de problemas y la información sobre la garantía. Incluye pasos detallados para la instalación de la bomba, el filtro y las luces de su estanque.
Preview Cabezal de potencia para estanque Aquascape 91142: Guía de instalación, mantenimiento y solución de problemas
Guía completa del cabezal motorizado para estanques Aquascape (modelo 91142) que cubre información sobre instalación, seguridad, especificaciones, mantenimiento, resolución de problemas y garantía.
Preview Manual del usuario del estanque de peces sobre el suelo VEVOR DS-207
Obtenga instrucciones detalladas de montaje y una lista de piezas para el estanque de peces elevado VEVOR DS-207. Este manual de usuario le guiará en la instalación de su estanque exterior fácilmente.
Preview Manual de funcionamiento del filtro para estanques biológicos Sunsun serie CBF-350
Manual de funcionamiento completo de los filtros biológicos para estanques Sunsun CBF-350, CBF-350B y CBF-350C (modelos 50107, 50108 y 50114). Incluye especificaciones técnicas detalladas, normas de seguridad, instrucciones de instalación y procedimientos de mantenimiento para una calidad óptima del agua del estanque.
Preview Manual de funcionamiento de la bomba de estanque ajustable SuperECO SUNSUN CET-8000 y CET-15000
Manual de funcionamiento oficial de las bombas de estanque ajustables SuperECO de SUN modelos CET-8000 y CET-15000. Aprenda sobre las características, la instalación, el funcionamiento y la solución de problemas para una circulación eficiente del agua en estanques y acuarios.