Fieldpiece SM482V

Fieldpiece SM482V Wireless 4-Port SMAN Refrigerant Manifold with Vacuum Gauge

Manual de instrucciones

Model: SM482V | Brand: Fieldpiece

Producto terminadoview

The Fieldpiece SM482V is an advanced wireless 4-port SMAN refrigerant manifold designed for comprehensive HVAC and Refrigeration diagnostics and service. This digital manifold accurately measures low and high pressure, and calculates superheat and subcooling. It features protected thermocouple jacks for temperature measurements and integrates with Job Link Psychrometer probes for enhanced functionality. The device is built for durability with a heavy-duty casing and IP55 dust and water resistance.

Fieldpiece SM482V Digital Manifold Front View

Figura 1: Frente view of the Fieldpiece SM482V Wireless 4-Port SMAN Refrigerant Manifold, showing the digital display and valve controls.

Características principales

Configuración y uso inicial

  1. Instalación de la batería: Open the battery compartment on the rear of the unit. Insert 6 AA batteries, ensuring correct polarity. Close the compartment securely.
  2. Encendido: Press the power button to turn on the manifold. The display will illuminate and show initial readings.
  3. Selección de refrigerante: Use the "SELECT" button to cycle through the pre-loaded refrigerants. Choose the appropriate refrigerant for your application.
  4. Presión cero: Before connecting to a system, ensure all valves are closed and press the "ZERO PRESSURE" button to calibrate the pressure sensors.
  5. Conexión de sondas: Connect thermocouple pipe clamps to the protected jacks for temperature measurements. For wireless integration, ensure Job Link Psychrometer probes are paired according to their respective manuals.
Fieldpiece SM482V with hands connecting hoses

Figure 2: The SM482V manifold being connected to an HVAC system, demonstrating hose attachment points.

Instrucciones de funcionamiento

Pressure and Temperature Measurement

Connect the manifold hoses to the high and low-pressure ports of the HVAC/R system. Open the appropriate valves on the manifold to read system pressures. The display will show real-time pressure readings, along with superheat and subcooling calculations based on connected temperature probes.

Medición de vacío

To measure vacuum, connect the vacuum pump to the manifold's vacuum port. Open the vacuum valve and start the pump. The integrated micron gauge will display the vacuum level. Monitor the reading until the desired vacuum is achieved.

System Tightness Test (Nitrogen Pressure Test)

The SM482V features a temperature-compensated nitrogen pressure test. Connect a nitrogen tank to the system via the manifold. Press the "N2 TEST" button to initiate the test. The manifold will record the initial pressure and monitor for pressure differential (Pdif) over time, indicating potential leaks. Press "STOP/EXIT" to end the test.

Registro de datos

The manifold can log up to 168 hours of data. To start data logging, refer to the specific instructions in the full user manual or the Job Link System App. Logged data can be retrieved and analyzed via the Job Link App.

Fieldpiece SM482V in use on an outdoor HVAC unit

Figure 3: An HVAC technician using the Fieldpiece SM482V on an outdoor air conditioning unit.

Mantenimiento

Fieldpiece SM482V with included soft case

Figure 4: The Fieldpiece SM482V manifold alongside its protective soft case.

Solución de problemas

ProblemaPosible causaSolución
Lecturas de presión inexactasUncalibrated sensors, leaky hoses/gaskets, incorrect refrigerant selected.Perform "ZERO PRESSURE" calibration. Inspect and replace worn hoses or gaskets. Verify correct refrigerant is selected.
Vacuum Reading FluctuationsMoisture in system, internal manifold leak, contaminated hoses.Ensure system is thoroughly evacuated. Check manifold for internal leaks (refer to service manual). Purge hoses with nitrogen before vacuuming.
La pantalla no se enciendeBaterías agotadas, instalación incorrecta de baterías.Reemplace las baterías por unas nuevas. Verifique la polaridad de las baterías.
Problemas de conexión inalámbricaOut of range, interference, un-paired probes.Ensure manifold and probes are within range (up to 1000ft line of sight). Reduce interference sources. Re-pair probes according to their instructions.

Presupuesto

CaracterísticaDetalle
ModeloSM482V
Peso del artículo5.79 libras (2.63 kg)
Dimensiones del producto (L x An x Al)5 x 10.25 x 11.25 pulgadas (12.7 x 26.0 x 28.6 cm)
MaterialPlástico ABS
Fuente de poder6 pilas AA
Duración de la batería405 hours (with backlight and wireless OFF)
Mostrar5" (12.7 cm) LCD w/ backlight
alcance inalámbrico1000' (305 m) line of sight
Presión máxima del colector870 psig (6000 kPa)
Puerto de vacío3/8" for fast evacuations
Refrigerant Recovery/Charging Port1/4"
Suction Line and Liquid Line Ports1/4"
Clasificación de protección de entradaIP55 (resistencia al polvo y al agua)
Entorno operativo14° to 122° F (-10° to 50° C) at <75% RH
Entorno de almacenamiento-4° to 140° F (-20° to 60° C) at <80% RH (w/o batteries)
Puerto de datosUSB-C for extracting data logs and updating firmware
Fieldpiece SM482V Specifications Comparison Table

Figure 5: Detailed specifications table comparing SM382V and SM482V models.

Información de garantía

The Fieldpiece SM482V Wireless 4-Port SMAN Refrigerant Manifold comes with a Garantía limitada de 1 años from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For detailed warranty terms, conditions, and limitations, please refer to the official warranty document included with your product or visit the Fieldpiece official websitio.

Nota: The warranty does not cover damage caused by misuse, accident, unauthorized modification, neglect, or improper operation.

Información de contacto y soporte

For technical assistance, product inquiries, or warranty claims, please contact Fieldpiece customer support through the following channels:

When contacting support, please have your product model number (SM482V) and purchase date available.

Documentos relacionados - SM482V

Preview Manual del operador del colector de refrigerante Fieldpiece SMAN®
Manual del operador del colector de refrigerante Fieldpiece SMAN® con medidor de vacío incorporado (modelos SM382V y SM482V), que detalla características, funcionamiento, especificaciones y mantenimiento para profesionales de HVACR.
Preview Manual del operador del colector de refrigerante Fieldpiece SMAN® con vacuómetro incorporado
Operator's manual for the Fieldpiece SMAN® Refrigerant Manifold with Built-in Vacuum Gauge (Models SM382V and SM482V). This guide provides HVACR professionals with detailed instructions on features, operation, maintenance, and safety for accurate refrigerant management and system diagnostics.
Preview Manual del operador del colector de refrigerante Fieldpiece SMAN
Manual completo del operador para los colectores de refrigerante Fieldpiece SMAN (modelos SM382V y SM482V) con vacuómetros integrados. Abarca características, operación, mantenimiento, especificaciones, seguridad y resolución de problemas para profesionales de HVACR.
Preview Fieldpiece SMAN® Coletor de Refrigerante con Vacuómetro Incorporado - Manual del Operador
Manual del operador detallado para los coletores de refrigerante Fieldpiece SMAN® con vacuómetro incorporado (modelos SM382VINT y SM482VINT). Configure la operación, seguridad, mantenimiento y especificaciones para profesionales de HVACR.
Preview Manual de uso de colectores para fluido frigorífico Fieldpiece SMAN® con jauge à vide integrado
Manual de uso completo para colectores de fluido frigorífico Fieldpiece SMAN® modelos SM382VINT (3 puertos) y SM482VINT (4 puertos). Este documento cubre las características, el funcionamiento, los procedimientos de seguridad, el mantenimiento, las especificaciones técnicas y la configuración.
Preview Manual del operador del colector de refrigerante + medidor de micras Fieldpiece SM480V SMAN
Comprehensive operator's manual for the Fieldpiece SM480V SMAN Refrigerant Manifold and Micron Gauge, detailing features, operation, maintenance, specifications, and compliance for HVACR professionals. Covers setup, measurements, calculations, menu functions, and troubleshooting.