ACiQ B0DHFF2DKL

Manual del usuario del sistema de bomba de calor con inversor central ACiQ de 2.5 toneladas y 17 SEER2

Model: B0DHFF2DKL

1. Introducción

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Información de seguridad

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Seguridad eléctrica: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Manejo de refrigerante: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Instalación: Installation must be performed by a licensed HVAC professional.
  • Equipo de protección personal: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Características principales

  • Tecnología inversora: Proporciona un control de temperatura preciso, un consumo de energía reducido y un funcionamiento más silencioso.
  • Alta eficiencia: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Amplio rango operativo: Reliable performance from -13°F to 122°F.
  • Funcionamiento silencioso: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Componentes duraderos: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Refrigerante ecológico: Utilizes R-454B refrigerant.
  • Instalación flexible: Supports horizontal and vertical air handler installation.
  • Controles inteligentes: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Componentes sobreview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Unidad de tratamiento de aire interior
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • Termostato WiFi
  • Surge Protector
  • Adaptador de carga CPS
  • Manga de la pared
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Figura 1: Encimaview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Configuración e instalación

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Comprobaciones previas a la instalación

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Asegúrese de que haya suficiente espacio para las unidades interiores y exteriores, lo que permite un flujo de aire adecuado y acceso para mantenimiento.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Figura 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Ubicación de la unidad exterior

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Figura 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Instrucciones de funcionamiento

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Modos básicos de funcionamiento

  • Modo de enfriamiento: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Modo de calefacción: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Modo de ventilador: Hace circular el aire sin calentar ni enfriar.
  • Modo automático: Cambia automáticamente entre calefacción y refrigeración para mantener la temperatura establecida.
ACiQ outdoor unit operating in extreme heat

Figura 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Figura 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Controles inteligentes

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Figura 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Mantenimiento

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Reemplazo del filtro de aire: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Limpieza de la unidad exterior: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Sistema de drenaje: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Inspección profesional: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Solución de problemas

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Sin energía: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Calefacción/refrigeración insuficiente: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Ruidos inusuales: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Fugas de agua: Check condensate drain line for blockages.

9. Especificaciones

Dimensions of ACiQ indoor and outdoor units

Figura 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Figura 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Figura 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

CaracterísticaDetalle
Capacidad de enfriamiento31,000 BTU/hora
Capacidad de calentamiento30,000 BTU/hr (at 47°F)
Clasificación SEER218.8
Clasificación HSPF29.7
Tipo de refrigeranteR-454B
Fuente de alimentación de la unidad interior115/208/230V, 60Hz, 1Ph
Fuente de alimentación de la unidad exterior208/230 V, 60 Hz, monofásico
Longitud máxima de tubería164 pies (50 m)
Max Height Difference82 pies (25 m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Peso neto de la unidad interior128.97 libras
Peso neto de la unidad exterior164.02 libras

10. Garantía y soporte

ACiQ offers a comprehensive warranty for this heat pump system:

  • Garantía de piezas: 7 años
  • Garantía del compresor: 12 años

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ websitio.

Documentos relacionados - B0DHFF2DKL

Preview Sistemas de calefacción de una sola zona ACiQ 9K-24K: Manual de instalación y del usuario
Manual de instalación y manejo de los sistemas de calefacción monozona ACiQ 9K-24K Standard Heat. Esta guía detalla la instalación, el funcionamiento, la seguridad y el mantenimiento de los aires acondicionados ACiQ, incluyendo las especificaciones del modelo e información sobre el refrigerante R454B.
Preview Manual de instalación de sistemas de inversores centrales ACiQ
Manual de instalación completo para sistemas de aire acondicionado y bomba de calor con inversor central ACiQ, que detalla precauciones de seguridad, tuberías de refrigerante, instalación de la unidad exterior, cableado, especificaciones de energía, evacuación de aire y procedimientos de prueba de funcionamiento.
Preview Manual de instalación y del propietario del manejador de aire mural ACiQ y del condensador monozona para calor extremo
Este manual proporciona instrucciones detalladas de instalación, funcionamiento y seguridad para los manejadores de aire de pared ACiQ y los condensadores de zona única de calor extremo, que cubren los modelos ACIQ-06W-HH-MD a ACIQ-24ZPL-HP230C.
Preview Manual de instalación de la unidad exterior de los sistemas centrales inversor ACiQ
Manual de instalación completo para unidades exteriores de sistemas de inversor central ACiQ, que cubre precauciones de seguridad, tuberías de refrigerante, cableado, instalación de unidades y procedimientos de prueba para modelos como ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB y otros.
Preview Sistema de bomba de calor por conductos ACiQ Next Gen: Guía de inicio rápido para el cableado del termostato
Esta guía proporciona información esencial para conectar y cablear termostatos al sistema de bomba de calor por conductos ACiQ Next Gen. Detalla las opciones de conexión recomendadas y alternativas, incluyendo la configuración de los interruptores DIP y del bloque de terminales para distintos tipos de termostatos.
Preview Manual de instalación y del propietario del manejador de aire y condensador mini-split ACiQ Essentials
Manual completo de instalación y uso para los sistemas de tratamiento de aire y condensador minisplit ACiQ Essentials. Este manual abarca las precauciones de seguridad, la identificación de piezas, el funcionamiento a distancia, los procedimientos de instalación, las pruebas de funcionamiento, el mantenimiento y la resolución de problemas para diversos modelos. El manual también incluye información esencial sobre el mantenimiento de sistemas que utilizan el refrigerante inflamable R454B, haciendo hincapié en los protocolos de seguridad y el cumplimiento normativo. Está diseñado para instaladores profesionales y usuarios finales, con el fin de garantizar el funcionamiento seguro y eficiente de los sistemas de bomba de calor minisplit ACiQ.