1. Introducción
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the TRU COMPONENTS Signal Pillar, model TC-12835336. This device is designed for industrial signaling applications, featuring red and green LED indicators with continuous or flashing light modes and an IP65 protection rating.
2. Información de seguridad
- Lea todas las instrucciones cuidadosamente antes de la instalación y operación.
- La instalación solo debe ser realizada por personal calificado.
- Asegúrese de que la fuente de alimentación esté desconectada antes de realizar cualquier instalación, mantenimiento o solución de problemas.
- Verifique el volumen correctotage (24V) is supplied to prevent damage to the unit.
- Do not expose the device to conditions beyond its specified IP65 rating.
- Evite la exposición directa de los ojos a la luz LED durante períodos prolongados.
3. Producto terminadoview
The TRU COMPONENTS Signal Pillar TC-12835336 is a robust signaling device with two LED segments (red and green) for clear visual indication in various industrial environments.

Figura 1: TRU COMPONENTS Signal Pillar TC-12835336. This image displays the signal pillar with its black base, threaded mounting shaft, and two translucent LED segments: red on top and green below. A bundle of multi-colored wires extends from the base for electrical connection.
Componentes:
- Segmentos LED: Red and Green, providing visual status.
- Alojamiento: Durable black housing with a diameter of 55 mm.
- Hilo de montaje: Para una instalación segura.
- Arnés de cableado: Multi-colored wires for power and control connections.
4. Especificaciones
| Característica | Detalle |
|---|---|
| Número de modelo | TC-12835336 |
| Colores claros | Rojo, verde |
| Modos de iluminación | Continuous or Flashing |
| Diámetro | Diámetro 55 mm |
| Clasificación de protección | IP65 |
| Volumentage | 24 V |
| Fabricante | COMPONENTES TRU |
| País natal | Porcelana |
5. Configuración e instalación
- Desconexión de energía: Ensure all power to the installation area is disconnected before beginning.
- Montaje: Securely mount the signal pillar using its threaded base. Ensure the mounting surface is stable and capable of supporting the device.
- Alambrado: Connect the signal pillar's wires to the appropriate 24V power supply and control system. Refer to the wiring diagram (if provided separately with the product) for specific connections for continuous or flashing modes. Typically, different wires control each LED segment and the flashing function.
- Sello ambiental: Ensure the IP65 rating is maintained after installation by properly sealing all connections and mounting points, especially in environments where dust or water ingress is a concern.
- Conexión de energía: Once all connections are secure and verified, restore power to the system.
6. Instrucciones de funcionamiento
The TRU COMPONENTS Signal Pillar operates by receiving a 24V signal to illuminate its LED segments. The specific wiring configuration determines whether a segment illuminates continuously or flashes.
- Iluminación continua: Apply 24V to the designated wire for the desired LED segment (e.g., red or green) to achieve continuous illumination.
- Iluminación intermitente: If wired for flashing operation, applying 24V to the corresponding wire will activate the flashing mode for that LED segment. Consult your system's wiring diagram for specific control signals.
- Multiple Segments: Both red and green segments can be activated independently or simultaneously, depending on the control system's design.
7. Mantenimiento
The TRU COMPONENTS Signal Pillar is designed for low maintenance. Regular checks can ensure optimal performance.
- Limpieza: Periodically clean the exterior of the signal pillar with a soft, damp Paño. No utilice limpiadores abrasivos ni disolventes.
- Inspección: Regularly inspect the housing and wiring for any signs of damage, wear, or loose connections.
- Integridad del sello: For IP65 rated protection, ensure all seals and cable glands remain intact and properly tightened.
- Desconexión de energía: Desconecte siempre la alimentación antes de realizar cualquier mantenimiento.
8. Solución de problemas
| Problema | Posible causa | Solución |
|---|---|---|
| Signal pillar does not illuminate. | No power supply; incorrect wiring; faulty LED segment. | Check 24V power supply; verify wiring connections against diagram; if power and wiring are correct, the LED segment may require replacement. |
| LED segment illuminates continuously instead of flashing (or vice-versa). | Incorrect wiring for flashing/continuous mode. | Review wiring diagram and ensure correct connections for the desired operating mode. |
| Operación intermitente. | Conexión de cableado suelta; fuente de alimentación inestable. | Inspect all wiring connections for tightness; check power supply stability. |
Si los pasos de solución de problemas no resuelven el problema, comuníquese con el servicio de atención al cliente o con un técnico calificado.
9. Garantía y soporte
For information regarding warranty coverage, technical support, or replacement parts, please refer to the documentation provided with your purchase or contact TRU COMPONENTS customer service. Keep your purchase receipt as proof of purchase.
Manufacturer: TRU COMPONENTS