Acrel DTSD1352

Manual del usuario del medidor de energía bidireccional trifásico Acrel DTSD1352

Model: DTSD1352 | Brand: Acrel (Manufactured by TGLGTQPX)

1. Introducción

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Acrel DTSD1352 Three Phase Bidirectional Energy Meter. This device is designed for accurate measurement of three-phase energy consumption and generation, featuring RS485 communication for integration into monitoring systems. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.

2. Información de seguridad

ADVERTENCIA: Riesgo de descarga eléctrica.

  • La instalación y el mantenimiento solo deben ser realizados por electricistas calificados.
  • Ensure all power is disconnected before installing or servicing the meter.
  • No toque terminales activos.
  • Verify correct wiring connections to prevent damage to the meter or electrical system.
  • The meter must be installed in a dry, well-ventilated area, free from excessive dust, corrosive gases, and direct sunlight.

3. Producto terminadoview

The Acrel DTSD1352 is a compact and robust three-phase multi-function energy meter. It features a clear LCD display for real-time data, intuitive control buttons, and various connection terminals.

Frente view of the Acrel DTSD1352 energy meter showing the LCD display, control buttons, and terminal connections.

Figura 3.1: Frente view of the DTSD1352 meter. This image displays the main LCD screen showing power readings (e.g., 0.00 kW), the "SET" button, and three orange arrow buttons for navigation. Terminal blocks are visible at the top and bottom for electrical connections.

Angular view of the Acrel DTSD1352 energy meter, showing the side profile and additional terminal details.

Figura 3.2: Angular view of the DTSD1352 meter. This perspective highlights the compact design and the various input/output terminals on the top and bottom, as well as the side labeling for model identification.

4. Especificaciones

The following table outlines the key technical specifications of the Acrel DTSD1352 energy meter. For detailed information, refer to the product datasheet.

Table of technical specifications for the Acrel DTSD1352 energy meter, including voltage, current, measurement performance, pulse, communication, outline, and environment details.

Figura 4.1: Detailed technical specifications. This image presents a table covering various parameters such as reference voltage (3*57.7/100V, 3*220/380V, 3*380V), reference frequency (50Hz), maximum current (6A, 80A), accuracy (Class 0.5S), communication interface (RS485, MODBUS-RTU), dimensions (127*88*70 mm), and environmental conditions (operating temperature -25~55℃, humidity ≤95%).

Tabla 4.1: Especificaciones generales
ParámetroValor
Vol de referenciatage3*57.7/100V, 3*220/380V, 3*380V
Frecuencia de referencia50 Hz
Corriente máxima6A, 80A (depending on model)
Accuracy of active kWhClase 0.5S
Interfaz de comunicaciónRS485
Protocolo de comunicaciónModbus RTU
Dimensiones (L*An*Al)127 mm x 88 mm x 70 mm
Temperatura de funcionamiento-25℃ a 55℃
Temperatura de almacenamiento-40℃ a 70℃
Humedad≤95% (sin condensación)
Altitud<2000 m
Peso del artículo7.1 onzas (aprox. 200 g)

5. Instalación y cableado

Proper installation and wiring are critical for the accurate and safe operation of the DTSD1352 meter. Refer to the diagrams below for connection methods.

Wiring diagrams for the Acrel DTSD1352 energy meter, showing both direct connection (3P4W) and connection via Current Transformers (CTs).

Figura 5.1: Wiring diagrams. This image illustrates two primary wiring methods: a 3-phase 4-wire (3P4W) direct connection where power lines (A, B, C, N) connect directly to the meter, and a connection via Current Transformers (CTs) for higher current applications, showing the CTs connected to the respective phase lines and then to the meter.

5.1 Direct Connection (3P4W)

For direct connection, ensure the phase lines (A, B, C) and neutral (N) are connected to the corresponding terminals on the meter. This method is typically used for lower current applications where the meter can directly handle the load current.

  • Connect Phase A to terminal 'A'.
  • Connect Phase B to terminal 'B'.
  • Connect Phase C to terminal 'C'.
  • Connect Neutral to terminal 'N'.
  • Asegúrese de que todas las conexiones estén seguras y adecuadamente aisladas.

5.2 Connection via Current Transformers (CTs)

For higher current applications, the DTSD1352 meter can be connected via external Current Transformers (CTs). This method scales down the current to a measurable level for the meter.

  • Install the CTs on each phase line (A, B, C).
  • Connect the secondary windings of the CTs to the corresponding current input terminals (e.g., Ia*, Ia, Ib*, Ib, Ic*, Ic) on the meter.
  • Ensure the polarity of the CTs is correct (P1/K to the source side, P2/L to the load side, and S1/S2 to the meter). Incorrect polarity will result in inaccurate readings.
  • Conectar el voltage inputs (Ua, Ub, Uc, N) directly from the respective phases and neutral to the meter.
  • It is recommended to install a fuse on the voltage input lines for protection.

Important: Always ensure the CT secondary circuit is closed before applying power to the primary circuit. Never open the secondary circuit of a live CT.

6. Operación

Once installed and powered, the DTSD1352 meter will automatically begin measuring. The LCD display shows various parameters, which can be navigated using the control buttons.

6.1 Navegación de pantalla

  • Pantalla LCD: Shows real-time measurements such as voltage, current, active power, reactive power, power factor, frequency, and total energy (kWh).
  • "SET" Button: Used to enter the parameter setting mode or confirm selections.
  • Arrow Buttons (Left, Right, Up, Down): Used to navigate through different display screens or adjust parameter values in setting mode.

6.2 Reading Energy Data

Press the arrow buttons to cycle through the various measurement screens. Common readings include:

  • Energía activa total (kWh)
  • Energía activa avanzada (kWh)
  • Energía activa inversa (kWh)
  • Volumentage (V) per phase
  • Corriente (A) por fase
  • Potencia activa (kW) por fase y total
  • Reactive Power (kVar) per phase and total
  • Factor de potencia (PF)
  • Frecuencia (Hz)

6.3 Comunicación RS485

The meter supports RS485 communication with MODBUS-RTU protocol. This allows for remote reading of meter data and configuration. Refer to the MODBUS communication protocol document for detailed register addresses and commands.

7. Mantenimiento

The DTSD1352 energy meter is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.

  • Limpieza: Mantenga el medidor limpio y sin polvo. Utilice un paño suave y seco para limpiarlo. No utilice limpiadores abrasivos ni disolventes.
  • Conexiones: Periodically check all wiring connections to ensure they are tight and secure. Loose connections can lead to inaccurate readings or overheating.
  • Ambiente: Asegúrese de que el entorno operativo permanezca dentro de los rangos de temperatura y humedad especificados.
  • Calibración: The meter is factory calibrated. If you suspect inaccuracies, contact qualified service personnel for recalibration.

8. Solución de problemas

This section provides solutions to common issues you might encounter with the DTSD1352 meter.

Tabla 8.1: Guía de resolución de problemas
ProblemaPosible causaSolución
La pantalla del medidor está en blanco.No hay suministro de energía al medidor.Check the main power supply and wiring connections to the meter's voltage input terminals. Ensure fuses are intact.
Lecturas de energía inexactas.Incorrect wiring, incorrect CT ratio setting (if applicable), faulty CTs, or meter malfunction.Verify all wiring connections according to Section 5. Ensure CT polarity is correct. Check if the CT ratio programmed in the meter matches the physical CTs. If issues persist, contact technical support.
Fallo de comunicación RS485.Incorrect wiring of RS485 terminals (A/B), incorrect communication parameters (baud rate, parity, address), or software issue.Check RS485 A and B terminal connections. Verify communication settings (baud rate, data bits, stop bits, parity, meter address) in your master device match the meter's settings. Ensure proper termination resistors are used if necessary.
Meter shows "Error" or specific error codes.Fallo interno o problema operativo específico.Note down the error code and consult the full product manual or contact technical support for specific error code interpretations and solutions.

9. Garantía y soporte

This product is manufactured by TGLGTQPX and sold under the Acrel brand. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your vendor. General support for the Acrel DTSD1352 meter can be obtained through the manufacturer's official channels or your authorized distributor.

For technical assistance, troubleshooting beyond this manual, or spare parts, please contact:

  • Fabricante: TGLGTQPX
  • Marca del producto: acre
  • Modelo: DTSD1352
  • (Contact information such as website or email would typically be provided here by the manufacturer.)

Documentos relacionados - DTSD1352

Preview Manual de instrucciones de instalación y funcionamiento del contador eléctrico monofásico ADL100-ET
Guía completa de instalación y funcionamiento del contador eléctrico monofásico Acrel ADL100-ET. Este manual detalla las especificaciones técnicas, descripciones funcionales, instrucciones de cableado, menús de visualización, procedimientos de programación y protocolos de comunicación (Modbus RTU).
Preview Acrel D318 Harmonic Meter Operation Instruction Manual
Operation instruction manual for the Acrel D318 External Roche Coil and Switched Transformer Harmonic Meter. Details features, technical specifications, and connection methods for energy saving and power monitoring applications.
Preview Medidor inteligente Acrel ADL3000-E: Manual de instalación y funcionamiento
Instrucciones completas de instalación y funcionamiento del contador inteligente Acrel ADL3000-E, que abarcan especificaciones técnicas, cableado, funciones de visualización y protocolos de comunicación.
Preview Manual de instalación y funcionamiento del medidor de potencia de CC montado en riel DJSF1352-RN
This document provides comprehensive installation and operation instructions for the Acrel DJSF1352-RN rail-mounted DC power meter. It covers product specifications, technical parameters, wiring diagrams, operational guidance, menu settings, and communication protocols (Modbus-RTU, DLT645-07).
Preview Instrumento eléctrico multifunción tipo riel Acrel ACR10R con transformador de corriente de núcleo dividido externo - Manual de uso e instalación
Este manual proporciona instrucciones completas para el instrumento eléctrico multifunción de riel serie Acrel ACR10R, incluyendo sus especificaciones, funciones, instalación, programación y comunicación RS485 MODBUS-RTU. Detalla parámetros técnicos, modos de conexión, procedimientos de operación y guía para la resolución de problemas en aplicaciones de monitoreo de energía industrial y comercial.
Preview ATE 系列无线测温传感器安装说明 V1.7
本说明书详细介绍了 ATE 3-35kV户内开关柜和 0.4kV 低压柜.