Fluke FLUKE-107

Manual del usuario del multímetro digital portátil de corriente CA/CC Fluke 107

Modelo: FLUKE-107

Introducción

The Fluke 107 is a compact, handheld digital multimeter designed for basic electrical measurements. It provides accurate readings for voltage, current, resistance, capacitance, frequency, and duty cycle, along with continuity and diode test functions. Its portable design makes it suitable for various applications, from professional use to hobbyist projects.

Fluke 107 Digital Multimeter front view

Imagen: Frente view of the Fluke 107 Digital Multimeter, displaying its screen, rotary dial, and function buttons.

Información de seguridad

Respete siempre las precauciones de seguridad al utilizar cualquier equipo de prueba eléctrica. De lo contrario, podrían producirse lesiones o daños al medidor o al equipo bajo prueba.

¿Qué hay en la caja?

The Fluke 107 package typically includes the following components:

Fluke 107 Multimeter with test leads and magnetic strap

Image: The Fluke 107 Multimeter displayed alongside its included test leads and magnetic lanyard.

Configuración

Instalación de la batería

The Fluke 107 comes with two AAA batteries pre-installed. If replacement is needed:

  1. Asegúrese de que el multímetro esté apagado.
  2. Localice el compartimiento de la batería en la parte posterior del medidor.
  3. Open the battery compartment cover by twisting the lock and sliding it open.
  4. Remove the old batteries and insert two new AAA batteries, observing the correct polarity (+/-).
  5. Cierre bien la tapa del compartimento de la batería.

Conexión de cables de prueba

The Fluke 107 has three recessed banana jacks:

Always connect the black test lead to the COM jack. Connect the red test lead to the appropriate jack based on the measurement you intend to perform.

Using the Smart Strap Magnetic Lanyard

The included Smart Strap allows for hands-free operation by attaching the meter to a ferrous metal surface or by configuring it as a stand. The strap has a slot that fits into the meter's case and secures with Velcro. The magnetic end can then be used to attach the meter to metal surfaces or to itself to form a viewsoporte de ing.

Instrucciones de funcionamiento

Controles sobreview

The Fluke 107 features a central rotary selector knob and three soft-touch buttons:

Hand in glove operating Fluke 107 Multimeter

Image: A gloved hand adjusting the rotary dial of the Fluke 107 Multimeter, demonstrating its ergonomic design.

Funciones de medida

The meter is auto-ranging by default for most functions, simplifying operation.

  1. VolumentagMedición electrónica (CA/CC):
    • Gire el botón giratorio a V~ para vol CAtagmi o V- para volumen CCtage.
    • Conecte el cable de prueba rojo al conector VΩHz y el cable de prueba negro al conector COM.
    • Apply the test probes across the circuit or component to measure voltage.
  2. Medición de corriente (CA/CC):
    • Gire el botón giratorio a A~ (AC) or A- (DC). Use the yellow button to toggle between AC and DC if needed.
    • Connect the red test lead to the A (10A FUSED) jack and the black test lead to the COM jack.
    • Importante: Connect the meter in series with the circuit to measure current. Ensure the circuit is de-energized before connecting the meter.
  3. Medición de resistencia (Ω):
    • Gire el botón giratorio a Ω.
    • Conecte el cable de prueba rojo al conector VΩHz y el cable de prueba negro al conector COM.
    • Apply the test probes across the component. Ensure the circuit is de-energized.
  4. Prueba de continuidad:
    • Gire el botón giratorio a Ω. Press the yellow button until the continuity icon (speaker symbol) appears.
    • Conecte el cable de prueba rojo al conector VΩHz y el cable de prueba negro al conector COM.
    • A continuous beep indicates a complete circuit (resistance less than 70Ω). "OL" indicates an open circuit.
  5. Prueba de diodo:
    • Gire el botón giratorio a Ω. Press the yellow button until the diode icon (arrow with line) appears.
    • Conecte el cable de prueba rojo al conector VΩHz y el cable de prueba negro al conector COM.
    • Place the red probe on the anode and black probe on the cathode of the diode. The display shows the forward voltage drop. Reverse the probes; "OL" should be displayed for a good diode.
  6. Medición de capacitancia:
    • Turn the rotary knob to the capacitance symbol (-||-).
    • Conecte el cable de prueba rojo al conector VΩHz y el cable de prueba negro al conector COM.
    • Importante: Discharge capacitors before connecting them to the meter. Apply probes across the capacitor. Readings may take up to 18 seconds to stabilize.
  7. Frequency (Hz) and Duty Cycle (%) Measurement:
    • Select AC Volts or AC Amps función.
    • Presione el Hz% button to display frequency. Press again for duty cycle. Press a third time to return to voltagpantalla electrónica/actual.

Apagado automático

The meter automatically powers off after 20 minutes of inactivity to conserve battery life. This feature can be disabled if continuous operation is required.

Mantenimiento

Limpieza

Limpiar la carcasa con publicidadamp Paño y detergente suave. No utilice abrasivos ni disolventes. Mantenga la pantalla limpia y sin rayones.

Reemplazo de batería

Refer to the "Battery Installation" section under Setup for detailed instructions. Replace batteries when the low battery indicator appears on the display.

Fuse Check and Replacement

The Fluke 107 has a single internal fuse for the Amps function. To check the fuse:

  1. Gire el interruptor selector a la Ω posición.
  2. Plug the red test lead into the VΩHz jack.
  3. Insert the probe tip of the red test lead into the A (10A FUSED) jack until electrical contact is made.
  4. A reading of less than 0.5Ω indicates a good fuse. An "OL" reading indicates a blown fuse that requires replacement.

Fuse replacement requires opening the meter case by removing three screws. It is recommended that fuse replacement be performed by qualified personnel or a Fluke service center.

Solución de problemas

ProblemaPosible causaSolución
Se muestra "OL" (Sobrecarga)Input value exceeds selected range; open circuit in continuity/diode test; blown fuse in current mode.Ensure correct function/range is selected. Check for open circuits. Check fuse in current mode.
Sin pantalla o pantalla tenueLow battery; meter off; damaged display.Replace batteries. Turn meter ON. Contact service if display is damaged.
Lecturas inexactasLow battery; incorrect function/range; poor test lead connection; external interference.Replace batteries. Verify function/range. Ensure leads are fully inserted. Move away from strong electromagnetic fields.
No hay medición de corrienteBlown fuse; incorrect connection (not in series).Check and replace fuse if necessary. Ensure meter is connected in series with the circuit.

Presupuesto

ParámetroValor
Vol máximotage entre cualquier terminal y tierra600 V
Tasa de actualización de pantalla3 updates per second
Tipo de batería2 x AAA batteries (Alkaline or Lithium recommended)
Duración de la batería200 horas mínimo
Temperatura de funcionamiento0 °C a 40 °C (32 °F a 104 °F)
DC Volts Ranges6.000V, 60.00V, 600.0V (Accuracy: 0.5% + 3 counts)
AC Volts Ranges6.000V, 60.00V, 600.0V (Accuracy: 1% + 3 counts)
ACmV Range600.0mV (Accuracy: 3% + 3 counts)
DC Amps Ranges4.000A, 10.00A (Accuracy: 1.5% + 3 counts)
AC Amps Ranges4.000A, 10.00A (Accuracy: 1.5% + 3 counts)
Rangos de resistencia400.0Ω, 4.000kΩ, 40.00kΩ, 400.0kΩ, 4.000MΩ, 30.00MΩ (Accuracy: 0.5% + 2 or 3 counts, 1.5% + 3 counts for 40MΩ)
Capacitance Ranges50.00nF, 500.0nF, 5.000µF, 50.00µF, 500.0µF, 1000µF (Accuracy: 2% + 5 counts on two lowest, 5% + 5 counts on higher)
Rangos de frecuencia50.00Hz, 500.0Hz, 5.000kHz, 50.00kHz, 100.0kHz (Accuracy: 0.1% + 3 counts)
Ciclo de trabajo1% ~ 99% (Accuracy: 1% typical)
Diode Test Range2.000V (Accuracy: 10%)
Dimensiones del producto8.27 x 11 x 2.17 pulgadas; 7.05 onzas

Garantía y soporte

The Fluke 107 Digital Multimeter comes with a 1-year manufacturer warranty. For warranty claims, technical support, or service, please contact Fluke customer service or visit the official Fluke website. Ensure you have your product model number and purchase details available.

For additional resources and detailed user manuals, please refer to the official Fluke support channels.

Documentos relacionados - Fluke-107

Preview Multímetro digital portátil CAT III Fluke 107: Especificaciones técnicas
Especificaciones técnicas detalladas, características e información general del multímetro digital portátil Fluke 107 CAT III. Incluye mediciones eléctricas, clasificaciones de seguridad y detalles de pedido.
Preview Especificaciones del multímetro digital Fluke 107 CAT III es Kenmerken
Especificaciones detalladas, conocidas y técnicas indicadas para el multímetro digital Fluke 107 CAT III en formato de palma de mano. Incluye datos eléctricos y algunas especificaciones, cumplimiento, garantía e información sobre los precios del EURO-INDEX.
Preview Multímetros digitales de bolsillo Fluke 106/107: Especificaciones técnicas y características
Especificaciones técnicas detalladas, características destacadas del producto e información general sobre los multímetros digitales compactos Fluke 106 y 107. Conozca sus especificaciones eléctricas, precisión, características y equipo incluido.
Preview Manual de usuario de los multímetros digitales Fluke 106/107
Manual de usuario completo para los multímetros digitales Fluke 106 y 107, que incluye información de seguridad y funcionamiento del instrumento.view, mediciones, mantenimiento y especificaciones.
Preview Kit adaptador Fluke FEV100 para estaciones de carga de vehículos eléctricos: Datos técnicos y especificaciones
Explore las especificaciones técnicas, las características y los procedimientos de prueba del kit adaptador Fluke FEV100, diseñado para probar de forma segura y eficiente estaciones de carga de vehículos eléctricos (VEV). Incluye información de seguridad, compatibilidad y detalles de pedido.
Preview Multímetro de verdadero valor eficaz Fluke 110: Especificaciones técnicas y características
Especificaciones y características detalladas del multímetro compacto de verdadero valor eficaz Fluke 110, diseñado para instalaciones eléctricas precisas y resolución de problemas. Incluye precisión, clasificaciones de seguridad y accesorios.