Introducción
The Instrukart BH-60 Fixed Hexane Detector is designed for the continuous monitoring of Hexane gas, toxic gases, and other harmful gases in industrial environments, particularly in oil plants. This device features a display for real-time gas concentration readings. Upon detecting gas levels exceeding predefined setpoints, the BH-60 activates audible and visual alarms, prompting users to implement safety protocols to prevent potential explosions or poisoning incidents.
Key features of the BH-60 Hexane Detector include:
- Stable signal transmission, ensuring reliable data.
- High precision for accurate gas concentration measurements.
- Rapid response time to gas presence.
- Long operational life and short polarization time for the industrial-grade sensor.
- Explosion-proof structure design for enhanced safety in hazardous areas.
- Compatibility with 4-20mA standard signals for integration into Distributed Control Systems (DCS).
- Suitable for various industries including metallurgical, petroleum, chemical, and municipal sectors.
Contenido del paquete
Verifique que todos los elementos enumerados a continuación estén presentes en el paquete:
- 1 Unit of Instrukart BH-60 Fixed Hexane Detector

Image: The Instrukart BH-60 Fixed Hexane Detector, a blue industrial device with a digital display showing "%VOL" and "8.8.8.8", and a red alarm light on the side.
Configuración
Proper installation is crucial for the accurate and safe operation of the BH-60 detector. Consult local electrical codes and safety regulations before installation.
- Ubicación de montaje: Select a mounting location where the target gas is most likely to accumulate. For Hexane, which is heavier than air, mount the detector closer to the ground. Ensure the location is free from excessive vibration, direct sunlight, and extreme temperatures.
- Montaje seguro: Use appropriate hardware to securely mount the detector to a stable surface. The device features mounting brackets for this purpose.
- Alambrado:
- Asegúrese de que la energía esté desconectada antes de realizar el cableado.
- Connect the power supply (Corded Electric) according to the wiring diagram provided in the full technical manual.
- If integrating with a control system, connect the 4-20mA output signal wires to the designated input terminals of your DCS or PLC.
- Ensure all connections are tight and properly insulated to maintain the explosion-proof integrity.
- Encendido inicial: After all connections are secure, apply power to the detector. The device will undergo a self-test sequence. Allow a warm-up period (typically a few minutes) for the sensor to stabilize before expecting accurate readings.
- Verificación: Observe the display for initial readings. If an alarm sounds immediately, ensure the area is clear of gas and recheck connections.

Imagen: Un lado view of the Instrukart BH-60 Fixed Hexane Detector, highlighting the robust casing and connection points for wiring.
Instrucciones de funcionamiento
The BH-60 operates continuously once powered on. Understanding its indications is key to effective monitoring.
Mostrar lecturas
- The digital display shows the current gas concentration in %VOL (percentage by volume).
- Under normal conditions, the reading should be near zero or within safe limits.
Funciones de alarma
The detector is equipped with configurable alarm setpoints. When gas concentration exceeds these thresholds, the following occurs:
- Alarma audible: A distinct sound will be emitted from the device.
- Alarma visual: The red alarm light on the side of the unit will illuminate and/or flash.
- Salida de señal: The 4-20mA output signal will change, indicating an alarm condition to the connected control system.
Acción en caso de alarma: Immediately follow your facility's safety protocols for gas detection alarms. This typically involves evacuating the area, identifying the source of the leak, and initiating corrective measures.

Image: The Instrukart BH-60 Fixed Hexane Detector shown with a power adapter connected, illustrating its power input method.
Mantenimiento
Regular maintenance ensures the continued accuracy and reliability of your BH-60 detector.
- Inspección de rutina: Periodically inspect the detector for any physical damage, corrosion, or blockages to the sensor inlet. Keep the display clean for clear visibility.
- Calibración: Gas detectors require regular calibration to maintain accuracy. Refer to the full technical manual for detailed calibration procedures. It is recommended to calibrate the device at least once every 6-12 months, or as required by local regulations and operational conditions. Use certified calibration gases.
- Reemplazo del sensor: The sensor has a finite lifespan. If the detector consistently provides inaccurate readings, fails calibration, or indicates a sensor fault, the sensor may need replacement. Contact Instrukart support for sensor replacement services or guidance.
- Limpieza: Clean the exterior of the detector with a soft, damp paño. No utilice limpiadores abrasivos ni disolventes, ya que pueden dañar el casing o sensor.
Solución de problemas
This section addresses common issues you might encounter with the BH-60 detector.
| Problema | Posible causa | Solución |
|---|---|---|
| Sin pantalla/Sin energía | Fuente de alimentación desconectada o defectuosa. | Check power connections. Ensure the power source is active. Verify power cable integrity. |
| Constant alarm (no gas present) | Sensor fault, calibration issue, or environmental interference. | Perform a fresh air calibration. If the problem persists, the sensor may be faulty or require professional service. |
| Lecturas inexactas | Sensor contamination, expired sensor, or calibration drift. | Clean the sensor inlet. Perform calibration. If issues persist, consider sensor replacement. |
| No hay alarma cuando hay gas | Alarm setpoints too high, faulty alarm components, or sensor failure. | Verify alarm setpoints. Test alarm functionality (if applicable). Check sensor status. Contact support if necessary. |
For issues not covered here, or if troubleshooting steps do not resolve the problem, please contact Instrukart customer support.
Presupuesto
The following are the technical specifications for the Instrukart BH-60 Fixed Hexane Detector:
| Marca | Instrukart |
| Número de modelo | IK-BH-60 |
| Estilo | Fixed Gas Detector With Display |
| Fuente de poder | Eléctrico con cable |
| Dimensiones del producto (Pr. x An. x Al.) | 15D x 10W x 12H Centímetros |
| Peso del artículo | 0.8 kilogramos (800 g) |
| Número de artículos | 1 |
| País natal | India |
| Componentes incluidos | 1 Unit of BH-60 |
Garantía y soporte
The Instrukart BH-60 Fixed Hexane Detector is manufactured by Instrukart. For warranty information, please refer to the documentation provided with your purchase or contact Instrukart directly. Extended warranty plans may be available through third-party providers.
For technical support, service, or inquiries regarding calibration and sensor replacement, please contact Instrukart customer service. Ensure you have your model number (IK-BH-60) and purchase details available when contacting support.
Fabricante: Instrukart
Envasador: Plot 18, Street No: 1A, Czech Colony, Sanath Nagar, Hyderabad, Telangana 500018