AC Infinity AC-PHM3

AC Infinity pH Meter Kit (Model AC-PHM3) Instruction Manual

Brand: AC Infinity | Model: AC-PHM3

Introducción

The AC Infinity pH Meter Kit (Model AC-PHM3) is a high-precision digital instrument designed for accurate measurement of water acidity, alkalinity, and temperature. This device assists in optimizing water quality for various applications, including gardening, hydroponics, aquariums, swimming pools, and general water treatment. Its responsive lithium glass membrane sensor provides instant pH readings with a high accuracy of ±0.1 pH. The meter features an IP-67 rating, ensuring protection against moisture, heat, dust, and sand, and includes a sensor shield for probe safeguarding. The kit comes with 4.00 pH and 7.00 pH calibration solutions to maintain consistent accuracy and support proper probe storage.

¿Qué hay en la caja?

  • AC Infinity pH Meter (Model AC-PHM3)
  • 4.00 pH Calibration Solution
  • 7.00 pH Calibration Solution
  • Storage Solution (for probe maintenance)
  • Estuche protector de transporte

Configuración

Preparación inicial

  1. Unpack the Meter: Carefully remove the pH meter and accessories from the protective carrying case.
  2. Probe Hydration: Before first use, and after prolonged storage, soak the pH probe in the provided storage solution for approximately 30 minutes. This hydrates the lithium glass membrane, ensuring optimal performance and accuracy.
  3. Sonda de enjuague: After hydration, gently rinse the probe with distilled or deionized water. Do not wipe the glass membrane, as this can damage it.

Calibración

Regular calibration is crucial for maintaining the accuracy of your pH meter. The AC-PHM3 supports 2-point or 3-point calibration using the included 4.00 pH and 7.00 pH solutions. For best results, perform a 3-point calibration (4.00, 7.00, and 10.00 pH if a 10.00 pH solution is acquired separately) or at least a 2-point calibration (4.00 and 7.00 pH) before each critical measurement session or if readings become inconsistent.

  1. Preparar soluciones: Pour small amounts of the 4.00 pH and 7.00 pH calibration solutions into separate, clean containers. Ensure the solutions are at room temperature.
  2. Iniciar calibración: Turn on the pH meter. Refer to the meter's display for calibration mode instructions, typically activated by pressing a 'CAL' button.
  3. Calibrate with 7.00 pH: Immerse the rinsed probe into the 7.00 pH solution. Allow the reading to stabilize. The meter will typically indicate successful calibration (e.g., a smiley face or 'END').
  4. Calibrate with 4.00 pH: Rinse the probe thoroughly with distilled water. Immerse it into the 4.00 pH solution. Allow the reading to stabilize and confirm calibration.
  5. (Optional) Calibrate with 10.00 pH: If performing a 3-point calibration, rinse the probe and immerse it into a 10.00 pH solution (not included).
AC Infinity pH Meter displaying a 4.00 pH reading and 76.5 degrees Fahrenheit, indicating lab-grade precision.

Image: The AC Infinity pH Meter displaying a stable 4.00 pH reading, demonstrating its precision during calibration.

Instrucciones de funcionamiento

Tomando una medida

  1. Encender: Presione el botón de encendido para encender el medidor de pH.
  2. Sonda de enjuague: Always rinse the probe with distilled or deionized water before and after each measurement to prevent cross-contamination.
  3. Sonda de inmersión: Dip the pH probe into the sample solution you wish to test. Ensure the liquid level is above the sensor bulb.
  4. Estabilizar la lectura: Gently stir the probe in the solution and wait for the reading on the display to stabilize. The meter will typically indicate when the reading is stable.
  5. Lectura de registro: Note down the pH and temperature values displayed.
  6. Limpiar y almacenar: After measurement, rinse the probe thoroughly with distilled water and place it back into the storage solution or protective cap.
AC Infinity pH Meter submerged in a beaker of liquid, demonstrating its use for water quality testing.

Image: The AC Infinity pH Meter actively measuring the pH of a liquid sample en un vaso de precipitados.

Understanding the Sensor

The AC-PHM3 utilizes a sensitive lithium glass membrane sensor for rapid and accurate pH detection. This advanced sensor technology allows for quick determination of water's acidity and alkalinity, along with integrated temperature measurement, which is crucial for temperature-compensated pH readings.

Close-up of the AC Infinity pH Meter's lithium glass membrane sensor, highlighting its advanced water testing capability.

Imagen: Un detalle view of the lithium glass membrane sensor, the core component for advanced water testing.

Mantenimiento

Limpieza de la sonda

To ensure accurate and consistent readings, the pH probe should be cleaned regularly, especially after testing samples that may leave residue. Rinse the probe thoroughly with distilled water. For stubborn deposits, a mild cleaning solution specifically designed for pH probes can be used, followed by a thorough rinse.

Almacenamiento

Proper storage is vital for extending the lifespan of the pH probe. Always store the probe with its cap filled with the provided storage solution. Never store the probe dry or in distilled water, as this can dehydrate the glass membrane and lead to inaccurate readings or permanent damage.

Recalibration Frequency

The frequency of recalibration depends on usage and the accuracy required. For critical applications or frequent use, recalibrate the meter daily or every few days. For less frequent use, recalibrate at least once a week or whenever readings appear inconsistent. Always recalibrate after cleaning the probe or if the meter has been stored for an extended period.

AC Infinity pH Meter with an IP67 waterproof rating, emphasizing its durability and protection against water and dust.

Image: The AC Infinity pH Meter, showcasing its IP67 rating for enhanced durability and protection during use and maintenance.

Solución de problemas

ProblemaPosible causaSolución
Lecturas inexactas o inestables
  • Probe not properly hydrated
  • Probe is dirty or contaminated
  • Calibration solutions expired or contaminated
  • Meter not calibrated or improperly calibrated
  • Air bubbles on the probe
  • Soak probe in storage solution for 30 minutes
  • Clean probe with distilled water or pH cleaning solution
  • Use fresh calibration solutions
  • Perform a full 2-point or 3-point calibration
  • Gently tap the meter to dislodge bubbles
Meter Does Not Turn On
  • Baterías bajas o agotadas
  • Los contactos de la batería están sucios
  • Reemplazar las baterías
  • Limpiar los contactos de la batería
Tiempo de respuesta lento
  • Probe is dry or aged
  • Bajo samplas temperaturas
  • Re-hydrate probe in storage solution
  • Asegurarse deample is at room temperature

Presupuesto

CaracterísticaDetalle
Número de modeloAC-PHM3
Precisión±0.1 pH Accuracy
Tipo de sensorpH, Temperatura
Tipo de sondaLithium Glass Membrane
Clasificación IPIP67
Calibration Solutions Included4.00 pH, 7.00 pH
Peso del artículo1.96 libras
Dimensiones del paquete11.22 x 8.03 x 3.15 pulgadas
Detailed specifications of the AC Infinity pH Meter, including model, dimensions, sensor type, and calibration solutions.

Image: A visual summary of the AC Infinity pH Meter's key specifications and included calibration solutions.

Garantía y soporte

For warranty information, technical support, or assistance with your AC Infinity pH Meter Kit (Model AC-PHM3), please visit the official AC Infinity webSitio web o contacte con el departamento de atención al cliente. Conserve su recibo de compra como comprobante para cualquier reclamación de garantía.

AC Infinity Oficial Websitio: www.acinfinity.com