Aspiradora antiácaros XIAOMI 2 Pro

Xiaomi Dust Mite Vacuum Cleaner 2 Pro Instruction Manual

Model: Dust Mite Vacuum Cleaner 2 Pro

1. Producto terminadoview

The Xiaomi Dust Mite Vacuum Cleaner 2 Pro is designed for effective removal of dust mites and allergens from various fabric surfaces. It features powerful suction, high-frequency beating, UV-C sterilization, warm-air drying, and smart dust-mite detection to ensure a hygienic environment.

Xiaomi Dust Mite Vacuum Cleaner 2 Pro main unit

Imagen: Más alláview of the Xiaomi Dust Mite Vacuum Cleaner 2 Pro, showcasing su diseño compacto y componentes principales.

Key features of Xiaomi Dust Mite Vacuum Cleaner 2 Pro

Image: Visual summary of the vacuum cleaner's top features, including dual dust compartment, high-frequency tapping, suction power, UV light, smart mite detection, and 6-stagfiltración electrónica.

2. Configuración

2.1 Desembalaje

Carefully remove all components from the packaging. Retain the packaging for future storage or transport. Ensure all parts listed in the packing list are present and undamaged.

2.2 Identificación de componentes

  • Main Unit (with motor and handle)
  • Dust Collection Bin (dual compartment)
  • Cabezal de cepillo de rodillo
  • Cable de alimentación
  • Manual de usuario (este documento)

2.3 Montaje inicial

  1. Attach the roller brush head to the main unit by aligning the connectors and pushing until it clicks into place.
  2. Ensure the dust collection bin is securely attached to the main unit.
  3. Connect the power cord to the vacuum cleaner and then plug it into a suitable power outlet (220V).

3. Instrucciones de funcionamiento

3.1 Encendido / Apagado

Press the power button located on the handle to turn the vacuum cleaner on. Press it again to turn off the device.

3.2 Potencia de succión

The vacuum cleaner provides 16 kPa of powerful suction to effectively remove dust mites and particles from deep within fabrics.

16,000Pa suction power demonstration

Image: Illustration of the vacuum cleaner's powerful 16,000Pa suction lifting dust mites and debris from a fabric surface.

3.3 High-Frequency Beating

The roller brush delivers 72,000 taps per minute to dislodge mites and dust embedded in fabrics. This action, combined with the anti-tangle design, ensures thorough cleaning and reduces hair buildup.

72,000 taps per minute high-frequency action

Image: Close-up of the vacuum head demonstrating the high-frequency tapping mechanism on a mattress surface.

3.4 UV-C Sterilization and Ultrasonic Mite Disruption

Activate the UV-C sterilization feature to eliminate bacteria. The integrated ultrasonic waves further disrupt dust mite activity. For safety, the UV light automatically turns off when the vacuum is lifted from the surface.

LED UV sterilization with ultrasonic mite disruption

Image: The vacuum cleaner in operation, showing the purple glow of the LED UV light for sterilization and a safety icon indicating automatic shut-off when lifted.

3.5 65°C Warm-Air Drying

The vacuum cleaner can blow 65°C hot air to dry bedding and upholstery, creating an unfavorable environment for dust mites and ensuring constant dryness.

65 degree Celsius hot air drying feature

Image: The vacuum cleaner demonstrating its 65°C hot air drying function, with warm air being expelled to dry fabric surfaces.

3.6 Smart Dust-Mite Detection

The integrated mite sensor tracks mite levels in real-time and automatically adjusts suction power. The LED screen displays the mite index, mode, and status. Refer to the indicator lights:

  • Luz verde fija: Light Dust Mite Presence
  • Luz amarilla fija: Moderate Dust Mite Presence
  • Steady Orange Light: Heavy Dust Mite Presence
Smart dust mite detection indicator lights

Image: Close-up of the vacuum cleaner's display panel showing the smart dust mite detection system with color-coded indicators for mite presence levels.

4. Mantenimiento

Regular maintenance ensures optimal performance and extends the lifespan of your vacuum cleaner. Always unplug the device before performing any maintenance.

4.1 Cleaning the Dust Collection Bin

La aspiradora cuenta con un upgraded dual dust compartment design. This system separates larger debris from fine dust, preventing clogging and maintaining suction efficiency. The 0.8L clear dust bin allows for easy monitoring of fullness.

  1. Press the release button to detach the dust collection bin from the main unit.
  2. Open the bin and empty its contents into a waste receptacle.
  3. Separate the dust compartment from the filter compartment. Clean both compartments thoroughly.
  4. Rinse the dust bin and filter components with water if necessary. Ensure they are completely dry before reassembling.
  5. Reattach the dust bin to the main unit until it clicks securely.

4.2 Mantenimiento del filtro

El 6-stagsistema de filtración captures particles as small as 0.3 µm. Regular cleaning of the filters is crucial to prevent secondary air pollution and maintain suction power.

  1. Remove the filters from the dust collection bin.
  2. Tap the filters gently to dislodge accumulated dust.
  3. If washable, rinse the filters under running water. Do not use detergents.
  4. Deje que los filtros se sequen completamente al aire durante al menos 24 horas antes de volver a colocarlos. No utilice secadora ni calor directo.
  5. Replace filters if they are visibly damaged or if suction power significantly decreases even after cleaning.

4.3 Limpieza del cepillo de rodillo

Periodically check the roller brush for tangled hair or debris. The anti-tangle design minimizes buildup, but occasional cleaning is recommended.

  1. Detach the roller brush head from the main unit.
  2. Carefully remove any hair or fibers wrapped around the roller brush using scissors or a cleaning tool.
  3. Limpie el cepillo y su carcasa con un paño seco.
  4. Reattach the roller brush head.

5. Solución de problemas

ProblemaPosible causaSolución
El dispositivo no se enciende.El cable de alimentación no está bien conectado. No hay corriente en el tomacorriente.Asegúrese de que el cable de alimentación esté bien enchufado tanto al dispositivo como a una toma de corriente que funcione. Pruebe la toma de corriente con otro aparato.
Bajo poder de succión.Dust bin full. Filters clogged. Roller brush obstructed.Empty the dust bin. Clean or replace filters. Remove any obstructions from the roller brush.
La luz ultravioleta no funciona.Device lifted from surface. UV lamp mal funcionamiento.Ensure the vacuum cleaner is in full contact with the surface. If the issue persists, contact customer support.
Smart detection light always orange.High dust mite presence. Sensor dirty.Continue cleaning the area thoroughly. Clean the mite sensor window with a soft, dry cloth.

Si el problema persiste después de intentar estas soluciones, comuníquese con el servicio de atención al cliente.

6. Especificaciones

CaracterísticaDetalle
ModeloAspiradora antiácaros 2 Pro
MarcaXiaomi
Poder de succión16 kPa
High-Frequency Beating72,000 taps/min
EsterilizaciónUV-C Light, Ultrasonic Mite Disruption
Función de secado65°C Warm-Air Drying
Sistema de filtración6-Stage Filtration (captures 0.3 µm particles)
Capacidad del depósito de polvo0.8 L (Dual Compartment)
Fuente de poderEléctrico con cable
Volumentage220 voltios
Quétage500 vatios
Peso del artículo2.4 kilogramos
Factor de formaPortátil
Uso recomendadoMattress, Upholstery, Carpet

7. Garantía y soporte

7.1 Información de garantía

This product is covered by a manufacturer's warranty. Please refer to the warranty card included in your product packaging for specific terms and conditions, including warranty period and coverage details. Keep your proof of purchase for warranty claims.

7.2 Atención al cliente

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact XIAOMI customer support. Visit the official XIAOMI websitio o consulte la información de contacto proporcionada en la documentación de su producto.

También puedes visitar el Tienda XIAOMI en Amazon para obtener más información sobre el producto.